Calculation of Organ Doses for a Large Number of Patients Undergoing CT Examinations

被引:9
作者
Bahadori, Amir [1 ]
Miglioretti, Diana [2 ]
Kruger, Randell [3 ]
Flynn, Michael [4 ,5 ]
Weinmann, Sheila [6 ]
Smith-Bindman, Rebecca [7 ,8 ,9 ]
Lee, Choonsik [10 ]
机构
[1] NASA, Space Radiat Anal Grp, Johnson Space Ctr, Houston, TX USA
[2] Univ Calif Davis, Sch Med, Dept Publ Hlth Sci, Div Biostat, Davis, CA 95616 USA
[3] Marshfield Clin & Res Fdn, Dept Radiol, Marshfield, WI USA
[4] Henry Ford Hlth Syst, Dept Radiol, Detroit, MI USA
[5] Henry Ford Hlth Syst, Ctr Hlth Serv Res, Detroit, MI USA
[6] Kaiser Permanente Northwest, Ctr Hlth Res, Portland, OR USA
[7] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[8] Univ Calif San Francisco, Dept Epidemiol & Biostat, San Francisco, CA 94143 USA
[9] Univ Calif San Francisco, Dept Obstet Gynecol & Reprod Sci, San Francisco, CA USA
[10] NCI, Div Canc Epidemiol & Genet, Radiat Epidemiol Branch, NIH, Rockville, MD 20850 USA
基金
美国国家卫生研究院;
关键词
CT; dosimetry; informatics; Monte Carlo simulations; phantom; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; SCANS; POPULATION; PHANTOMS; CHILDREN; PROGRAM; FEMALE; FAMILY; INDEX;
D O I
10.2214/AJR.14.14135
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The objective of our study was to develop an automated calculation method to provide organ dose assessment for a large cohort of pediatric and adult patients undergoing CT examinations. MATERIALS AND METHODS. We adopted two dose libraries that were previously published: the volume CT dose index-normalized organ dose library and the tube current-exposure time product (100 mAs)-normalized weighted CT dose index library. We developed an algorithm to calculate organ doses using the two dose libraries and the CT parameters available from DICOM data. We calculated organ doses for pediatric (n = 2499) and adult (n = 2043) CT examinations randomly selected from four health care systems in the United States and compared the adult organ doses with the values calculated from the ImPACT calculator. RESULTS. The median brain dose was 20 mGy (pediatric) and 24 mGy (adult), and the brain dose was greater than 40 mGy for 11% (pediatric) and 18% (adult) of the head CT studies. Both the National Cancer Institute (NCI) and ImPACT methods provided similar organ doses (median discrepancy < 20%) for all organs except the organs located close to the scanning boundaries. The visual comparisons of scanning coverage and phantom anatomies revealed that the NCI method, which is based on realistic computational phantoms, provides more accurate organ doses than the ImPACT method. CONCLUSION. The automated organ dose calculation method developed in this study reduces the time needed to calculate doses for a large number of patients. We have successfully used this method for a variety of CT-related studies including retrospective epidemiologic studies and CT dose trend analysis studies.
引用
收藏
页码:827 / 833
页数:7
相关论文
共 24 条
[1]  
[Anonymous], 2002, Ann ICRP, V32, P5
[2]  
[Anonymous], 1986, MALE ADAM FEMALE EVA
[3]  
[Anonymous], 1987, SPECIFIC ABSORBED FR
[4]   Normalized CT Dose Index of the CT Scanners Used in the National Lung Screening Trial [J].
Cody, Dianna D. ;
Kim, Hyun-Jung ;
Cagnon, Christopher H. ;
Larke, Frederick J. ;
McNitt-Gray, Michael M. ;
Kruger, Randell L. ;
Flynn, Michael J. ;
Seibert, J. Anthony ;
Judy, Philip F. ;
Wu, Xizeng .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (06) :1539-1546
[5]  
Edyvean S., 1997, CT Scanner Dose Survey: Measurement Protocol - version 5.0 July 1997. Imaging and Performance Assessment of CT Scanners (ImPACT)
[6]   The UF/NCI family of hybrid computational phantoms representing the current US population of male and female children, adolescents, and adults-application to CT dosimetry [J].
Geyer, Amy M. ;
O'Reilly, Shannon ;
Lee, Choonsik ;
Long, Daniel J. ;
Bolch, Wesley E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (18) :5225-5242
[7]   CT scans in childhood and risk of leukaemia and brain tumours [J].
Hauptmann, Michael ;
Meulepas, Johanna M. .
LANCET, 2012, 380 (9855) :1736-1736
[8]   Paediatric head CT scan and subsequent risk of malignancy and benign brain tumour: a nation-wide population-based cohort study [J].
Huang, W-Y ;
Muo, C-H ;
Lin, C-Y ;
Jen, Y-M ;
Yang, M-H ;
Lin, J-C ;
Sung, F-C ;
Kao, C-H .
BRITISH JOURNAL OF CANCER, 2014, 110 (09) :2354-2360
[9]  
ImPACT, 2011, IMPACTS CT DOS TOOL
[10]  
Jones DG, 1991, NRPBR250