Management of Implant Exposure in One-Stage Breast Reconstruction Using Titanium-Coated Polypropylene Mesh: Sub-Mammary Intercostal Perforator Flap

被引:13
作者
De Riggi, Michele Antonio [1 ]
Rocco, Nicola [2 ]
Gherardini, Giulio [1 ]
Esposito, Emanuela [1 ]
D'Aiuto, Massimiliano [1 ]
机构
[1] Natl Canc Inst Naples IRCCS G Pascale, Breast Dept, Naples, Italy
[2] Univ Naples Federico II, Dept Clin Med & Surg, Via S Pansini 5, I-80131 Naples, Italy
关键词
Breast reconstruction; TiLOOP Bra; Submammary intercostal perforator flap; Implant exposure; QUALITY-OF-LIFE; TILOOP(R) BRA; COMPLICATIONS; SURGERY; TERM;
D O I
10.1007/s00266-016-0720-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
One-stage implant-based breast reconstruction using titanium-coated polypropylene mesh is a novel approach widely used in Europe. Complication rates in breast reconstruction with the use of titanium-coated meshes seem to be comparable to those in patients with implant-based breast reconstruction alone. However, the use of synthetic meshes in implant-based breast reconstructive surgery leads to new clinical scenarios with the need for the breast surgeon to face new complications. We present an innovative treatment of implant exposure in the absence of infection in patients who underwent nipple-sparing mastectomy and immediate breast reconstruction with silicone implants and titanium-coated polypropylene mesh by using a pedicled sub-mammary intercostal perforator flap. Four patients who experienced implant exposure without infection have been treated with the use of a sub-mammary intercostal perforator flap. Whole coverage of the exposed implant/mesh with a sub-mammary intercostal perforator flap was obtained in all cases. No post-operative complications have been observed, whereas a pleasant aesthetic result has been achieved. Patients' post-operative quality of life and satisfaction levels were measured by the European Organisation for Research and Treatment of Cancer breast cancer-specific quality of life QLQ-BR23 questionnaire and showed an average good satisfaction with the post-operative outcomes (mean QLQ-BR23 score 1.9). For the first time, a sub-mammary intercostal perforator flap has been used with the aim of treating implant exposures without removing the prosthesis even in the presence of synthetic meshes, when wound infection was excluded. Although tested on a small series, the sub-mammary intercostal perforator flap might represent a simple, versatile and cost-effective procedure for the management of implant exposure following nipple-sparing mastectomy and immediate reconstruction with silicone implants and synthetic meshes. It should be considered to avoid implant removal followed by delayed free flap reconstruction as "salvage surgery." This journal requires that the authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
引用
收藏
页码:896 / 900
页数:5
相关论文
共 15 条
  • [1] THE EUROPEAN-ORGANIZATION-FOR-RESEARCH-AND-TREATMENT-OF-CANCER QLQ-C30 - A QUALITY-OF-LIFE INSTRUMENT FOR USE IN INTERNATIONAL CLINICAL-TRIALS IN ONCOLOGY
    AARONSON, NK
    AHMEDZAI, S
    BERGMAN, B
    BULLINGER, M
    CULL, A
    DUEZ, NJ
    FILIBERTI, A
    FLECHTNER, H
    FLEISHMAN, SB
    DEHAES, JCJM
    KAASA, S
    KLEE, M
    OSOBA, D
    RAZAVI, D
    ROFE, PB
    SCHRAUB, S
    SNEEUW, K
    SULLIVAN, M
    TAKEDA, F
    [J]. JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1993, 85 (05) : 365 - 376
  • [2] TiLoop® Bra mesh used for immediate breast reconstruction: comparison of retropectoral and subcutaneous implant placement in a prospective single-institution series
    Casella D.
    Bernini M.
    Bencini L.
    Roselli J.
    Lacaria M.T.
    Martellucci J.
    Banfi R.
    Calabrese C.
    Orzalesi L.
    [J]. European Journal of Plastic Surgery, 2014, 37 (11) : 599 - 604
  • [3] Das DK, 2013, INT J COLLAB RES INT, V5, P398
  • [4] A short-term follow-up of implant based breast reconstruction using a titanium-coated polypropylene mesh (TiLoop® Bra)
    Dieterich, M.
    Reimer, T.
    Dieterich, H.
    Stubert, J.
    Gerber, B.
    [J]. EJSO, 2012, 38 (12): : 1225 - 1230
  • [5] Dieterich M, 2012, ARCH GYNECOL OBSTET, V286, P7
  • [6] Djohan Risal, 2008, Cleve Clin J Med, V75 Suppl 1, pS17
  • [7] Biological and synthetic mesh use in breast reconstructive surgery: a literature review
    Ellis, Hugh Logan
    Asaolu, Oluwatosin
    Nebo, Vivien
    Kasem, Abdul
    [J]. WORLD JOURNAL OF SURGICAL ONCOLOGY, 2016, 14
  • [8] A long-term study of outcomes, complications, and patient satisfaction with breast implants
    Handel, N
    Cordray, T
    Gutierrez, J
    Jensen, JA
    [J]. PLASTIC AND RECONSTRUCTIVE SURGERY, 2006, 117 (03) : 757 - 767
  • [9] Juri J, 2004, PLAST RECONSTR SURG, V114, P567, DOI 10.1097/01.PRS.0000128422.74454.23
  • [10] Oncoplastic breast surgery with latissimus dorsi myocutaneous flap for large defect in patients with ptotic breasts: is it feasible when combined with local flaps?
    Lee, Seungju
    Lee, Jeeyeon
    Lee, Seokwon
    Bae, Youngtae
    [J]. WORLD JOURNAL OF SURGICAL ONCOLOGY, 2014, 12