DETERMINATION OF LEAD IN HUMAN HAIR BY HIGH RESOLUTION CONTINUUM SOURCE GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROMETRY WITH MICROWAVE DIGESTION AND SOLID SAMPLING

被引:38
作者
Zhao, Li-Jiao [1 ]
Ren, Ting [1 ]
Zhong, Ru-Gang [1 ]
机构
[1] Beijing Univ Technol, Coll Life Sci & Bioengn, Beijing 100124, Peoples R China
基金
中国国家自然科学基金;
关键词
Direct solid sampling; High resolution continuum source graphite furnace atomic absorption spectrometry; Human hair; Lead; Microwave-assisted digestion; WHOLE-BLOOD; BIOLOGICAL SAMPLES; SCALP HAIR; EXPOSURE; TOXICITY; MANGANESE; CADMIUM; BIODIESEL; MODIFIERS; ELEMENTS;
D O I
10.1080/00032719.2012.689903
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The content of lead in human hair was measured by high resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GFAAS) combined with microwave-assisted digestion (MAD) and direct solid sampling (DSS). Hair strands were washed, dried, and then cut into three parts (root, middle portion, and tip). For MAD-GFAAS assays, approximately 0.25 g of hair was completely digested using a mixture of concentrated nitric acid and hydrogen peroxide in a closed system. In the DSS-GFAAS assays, 0.1-0.2 mg of dried hair was directly introduced into a graphite furnace using a solid autosampler. The temperature programs were optimized and the effects of various added modifiers were compared. The results indicated that NH4H2PO4 was the optimal modifier for analysis of Pb using GFAAS. Use of the optimal modifier and temperature program gave similar limits of detection for MAD-GFAAS and DSS-GFAAS of 1.16 ng/g and 0.82 ng/g, respectively. Both methods also produced satisfactory recoveries ranging from 98.69% to 103.14%. There was no significant difference observed between the Pb contents of hair strands determined by the MAD-GFAAS and DSS-GFAAS assays, which both indicated that the Pb levels increased along the hair strands. Comparison of the two methods revealed that DSS-GFAAS had several advantageous characteristics over MAD-GFAAS, including the need for much less sample material and having a less time-consuming procedure, lower sample blank absorbance, lower memory effect, and no risk of environmental pollution by digesting chemicals. The direct solid sampling technique can be employed as a good alternative to conventional wet digestion in AAS assays.
引用
收藏
页码:2467 / 2481
页数:15
相关论文
共 50 条
  • [1] Determination of lead, chromium, manganese and zinc in slurries of botanical and biological samples by electrothermal atomic absorption spectrometry using tungsten-containing chemical modifiers
    Acar, O
    [J]. MICROCHIMICA ACTA, 2005, 151 (1-2) : 53 - 58
  • [2] Agency I. A. E., 1978, IAEARL50
  • [3] [Anonymous], 2008, ASPECT CS 1 5 3
  • [4] Slurry sampling for determination of lead in marine plankton by electrothermal atomic absorption spectrometry
    Arslan, Zikri
    Tyson, Julian F.
    [J]. MICROCHEMICAL JOURNAL, 2007, 86 (02) : 227 - 234
  • [5] Accumulation of elements (S, As, Br, Sr, Cd, Hg, Pb) in two populations of Cancer pagurus: Ecological implications to human consumption
    Barrento, Sara
    Marques, Antonio
    Teixeira, Barbara
    Carvalho, Maria Luisa
    Vaz-Pires, Paulo
    Nunes, Maria Leonor
    [J]. FOOD AND CHEMICAL TOXICOLOGY, 2009, 47 (01) : 150 - 156
  • [6] A rapid solid sampling method for determination of nickel and copper along human hair by ETAAS
    Baysal, Asli
    Akman, Suleyman
    [J]. MICROCHEMICAL JOURNAL, 2011, 98 (02) : 291 - 296
  • [7] Determination of lead in hair and its segmental analysis by solid sampling electrothermal atomic absorption spectrometry
    Baysal, Asli
    Akman, Suleyman
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2010, 65 (04) : 340 - 344
  • [8] Hydrogen peroxide in basic media for whole blood sample dissolution for determination of its lead content by electrothermal atomization atomic absorption spectrometry
    Biasino, Jullany
    Dominguez, Jose Ramon
    Alvarado, Jose
    [J]. TALANTA, 2007, 73 (05) : 962 - 964
  • [9] Determination of lead in biological samples by high-resolution continuum source graphite furnace atomic absorption spectrometry with direct solid sampling
    Borges, Daniel L. Gallindo
    da Silva, Alessandra Furtado
    Welz, Bernhard
    Curtius, Adilson J.
    Heitmann, Uwe
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2006, 21 (08) : 763 - 769
  • [10] Direct determination of P in biodiesel by high-resolution continuum source graphite furnace atomic absorption spectrometry
    de Campos, Reinaldo Calixto
    Correia, Carolina Lyrio T.
    Vieira, Flavia
    Saint'Pierre, Tatiana D.
    Oliveira, Ana Cristina
    Goncalves, Rodrigo
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2011, 66 (05) : 352 - 355