Corrosion at the neck-stem junction as a cause of metal ion release and pseudotumour formation

被引:179
作者
Gill, I. P. S. [1 ]
Webb, J. [1 ]
Sloan, K. [1 ]
Beaver, R. J. [1 ]
机构
[1] Royal Perth Hosp, Joint Replacement Outcome Unit, Perth, WA 6000, Australia
来源
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME | 2012年 / 94B卷 / 07期
关键词
TOTAL HIP-ARTHROPLASTY; MODULAR FEMORAL-NECK; RESURFACING ARTHROPLASTY; EARLY FAILURE; REPLACEMENT; BEARINGS; DIAMETER; COBALT; COMPONENT; CHROMIUM;
D O I
10.1302/0301-620X.94B7.29122
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We present a series of 35 patients (19 men and 16 women) with a mean age of 64 years (36.7 to 75.9), who underwent total hip replacement using the ESKA dual-modular short stem with metal on-polyethylene bearing surfaces. This implant has a modular neck section in addition to the modular head. Of these patients, three presented with increasing post-operative pain due to pseudotumour formation that resulted from corrosion at the modular neck-stem junction. These patients underwent further surgery and aseptic lymphocytic vaculitis associated lesions were demonstrated on histological analysis. Retrieval analysis of two modular necks showed corrosion at the neck-stem taper. Blood cobalt and chromium levels were measured at a mean of nine months (3 to 28) following surgery. These were compared with the levels in seven control patients (three men and four women) with a mean age of 53.4 years (32.1 to 64.1), who had an identical prosthesis and articulation but with a prosthesis that had no modularity at neck-stem junction. The mean blood levels of cobalt in the study group were raised at 50.75 nmol/l (5 to 145) compared with 5.6 nmol/l (2 to 13) in control patients. Corrosion at neck-stem tapers has been identified as an important source of metal ion release and pseudotumour formation requiring revision surgery. Finite element modelling of the dual modular stem demonstrated high stresses at the modular stem-neck junction. Dual modular cobalt-chrome hip prostheses should be used with caution due to these concerns.
引用
收藏
页码:895 / 900
页数:6
相关论文
共 36 条
[1]  
Afolaranmi G A, 2008, Open Orthop J, V2, P10, DOI 10.2174/1874325000802010010
[2]   High failure rates with a large-diameter hybrid metal-on-metal total hip replacement CLINICAL, RADIOLOGICAL AND RETRIEVAL ANALYSIS [J].
Bolland, B. J. R. F. ;
Culliford, D. J. ;
Langton, D. J. ;
Millington, J. P. S. ;
Arden, N. K. ;
Latham, J. M. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2011, 93B (05) :608-615
[3]   FRETTING CORROSION ACCELERATES CREVICE CORROSION OF MODULAR HIP TAPERS [J].
BROWN, SA ;
FLEMMING, CAC ;
KAWALEC, JS ;
PLACKO, HE ;
VASSAUX, C ;
MERRITT, K ;
PAYER, JH ;
KRAAY, MJ .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (01) :19-26
[4]  
Chana R, 2012, J BONE JOINT SURG BR, V94B, P281, DOI [10.1302/0301-620X.94B2, 10.1302/0301-620X.94B2.27247]
[5]   Levels of metal ions after small- and large-diameter metal-on-metal hip arthroplasty [J].
Clarke, MT ;
Lee, PTH ;
Arora, A ;
Villar, RN .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (06) :913-917
[6]   Inflammatory pseudotumor associated with femoral nerve palsy following metal-on-metal resurfacing of the hip [J].
Clayton, Robert A. E. ;
Beggs, Ian ;
Salter, Donald M. ;
Grant, M. Helen ;
Patton, James T. ;
Porter, Daniel E. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (09) :1988-1993
[7]   Blood and urine metal ion levels in young and active patients after Birmingham hip resurfacing arthroplasty - Four-year results of a prospective longitudinal study [J].
Daniel, J. ;
Ziaee, H. ;
Pradhan, C. ;
Pynsent, P. B. ;
McMinn, D. J. W. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2007, 89B (02) :169-173
[8]   An unusual lymphocytic perivascular infiltration in tissues around contemporary metal-on-metal joint replacements [J].
Davies, AP ;
Willert, HG ;
Campbell, PA ;
Learmonth, ID ;
Case, CP .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :18-27
[9]  
Dunbar Michael J, 2010, Orthopedics, V33, P640, DOI 10.3928/01477447-20100722-30
[10]   IN-VIVO CORROSION OF MODULAR HIP-PROSTHESIS COMPONENTS IN MIXED AND SIMILAR METAL COMBINATIONS - THE EFFECT OF CREVICE, STRESS, MOTION, AND ALLOY COUPLING [J].
GILBERT, JL ;
BUCKLEY, CA ;
JACOBS, JJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (12) :1533-1544