Measurement Adherence in the Blood Pressure Self-Measurement Room

被引:16
作者
Wagner, Stefan [1 ]
Buus, Niels Henrik [3 ]
Jespersen, Bente [3 ]
Ahrendt, Peter [1 ]
Bertelsen, Olav W. [2 ]
Toftegaard, Thomas S. [1 ]
机构
[1] Aarhus Univ, Dept Engn, DK-8200 Aarhus, Denmark
[2] Aarhus Univ, Dept Comp Sci, DK-8200 Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Renal Med, DK-8000 Aarhus, Denmark
关键词
e-health; cardiology; cardiovascular disease; telemedicine; telehealth; home health monitoring; AMERICAN-HEART-ASSOCIATION; HYPERTENSION; HOME; RECOMMENDATIONS; RELIABILITY; STATEMENT; ACCURATE; SOCIETY; ISSUES;
D O I
10.1089/tmj.2013.0032
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background:Patients with hypertension or receiving blood pressure (BP)-lowering treatment are often required to self-measure their BP in a dedicated self-measurement room before consultation. Current praxis does not guarantee valid measurements, possibly leading to misdiagnoses or inappropriate antihypertensive medication. The aim of this study was to investigate patients' ability to correctly self-report and follow recommendations.Patients and Methods:We used a context-aware system to gather information on BP measurements and relevant context parameters. Patients were not informed that the system automatically collected behavior data and were instructed to self-report their measurements on a paper sheet as usual. We then compared the automatically recorded data with the self-reported data in order to detect any nonadherent reporting behavior. Also, we investigated the patients' ability to adhere to the measurement recommendations.Results:We found that (1) a third of all 113 participating patients failed to self-report measured BP data correctly and (2) none of the 642 measurements obtained adhered fully to the recommendations.Conclusions:Results indicate that context-aware technology may be useful for accurately modeling aspects of nonadherent patient behavior. This may be used to inform staff of the validity of the measurement and pinpoint patients in need of additional training or to design better aids to assist the patients. The developed system is generally applicable to other self-measurement environments, including the home setting and remote outpatient clinics, as it is built using telemedicine technology and thus well suited for remote monitoring and diagnosis.
引用
收藏
页码:826 / 833
页数:8
相关论文
共 50 条
[31]   Evaluation of a new rebound tonometer for self-measurement of intraocular pressure [J].
Dabasia, Priya L. ;
Lawrenson, John G. ;
Murdoch, Ian E. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2016, 100 (08) :1139-1143
[32]   Self Measurement of Blood Pressure for Control of Blood Pressure Levels and Adherence to Treatment [J].
Sebba Barroso de Souza, Weimar Kunz ;
Brandao Veiga Jardim, Paulo Cesar ;
Brito, Ludmila Porto ;
Araujo, Fabricio Alves ;
Lima Sousa, Ana Luiza .
ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2012, 98 (02) :167-173
[33]   Correlation of Blood Pressure Variability as Measured By Clinic, Self-measurement at Home, and Ambulatory Blood Pressure Monitoring [J].
Abellan-Huerta, Jos ;
Prieto-Valiente, Luis ;
Montoro-Garcia, Silvia ;
Abellan-Aleman, Jos ;
Soria-Arcos, Federico .
AMERICAN JOURNAL OF HYPERTENSION, 2018, 31 (03) :305-312
[34]   AMBULATORY BLOOD-PRESSURE MONITORING AND BLOOD-PRESSURE SELF-MEASUREMENT IN THE DIAGNOSIS AND MANAGEMENT OF HYPERTENSION [J].
APPEL, LJ ;
STASON, WB .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (11) :867-882
[35]   Control of arterial hypertension based on self-measurement of blood pressure: APACHE study [J].
Redon, J .
MEDICINA CLINICA, 2003, 120 (19) :728-733
[36]   Patient assessment of self-measurement of blood pressure: Results of a telephone survey in Germany [J].
Krecke, HJ ;
Lutkes, P ;
Maiwald, M .
JOURNAL OF HYPERTENSION, 1996, 14 (03) :323-326
[37]   Self-measurement of blood pressure: accuracy, patient preparation for readings, technique and equipment [J].
Campbell, NRC ;
Milkovich, L ;
Burgess, E ;
McKay, DW .
BLOOD PRESSURE MONITORING, 2001, 6 (03) :133-138
[38]   Self-measurement and self-titration in hypertension [J].
Bobrie, Guillaume ;
Postel-Vinay, Nicolas ;
Delonca, Jean ;
Corvol, Pierre .
AMERICAN JOURNAL OF HYPERTENSION, 2007, 20 (12) :1314-1320
[39]   Effect of verapamil on home self-measurement of blood pressure and heart rate in hypertensive patients [J].
Fernández-González, R ;
Gómez-Pajuelo, C ;
Gabriel, R ;
de la Figuera, M ;
Moreno, E .
BLOOD PRESSURE MONITORING, 2000, 5 (01) :23-30
[40]   Assessment of knowledge and skills of patients with hypertension related to self-measurement of blood pressure (SBPM) [J].
Dymek, Justyna ;
Skowron, Agnieszka ;
Polak, Wioletta ;
Golda, Anna .
ARTERIAL HYPERTENSION, 2015, 19 (01) :39-44