Measurement Adherence in the Blood Pressure Self-Measurement Room

被引:16
|
作者
Wagner, Stefan [1 ]
Buus, Niels Henrik [3 ]
Jespersen, Bente [3 ]
Ahrendt, Peter [1 ]
Bertelsen, Olav W. [2 ]
Toftegaard, Thomas S. [1 ]
机构
[1] Aarhus Univ, Dept Engn, DK-8200 Aarhus, Denmark
[2] Aarhus Univ, Dept Comp Sci, DK-8200 Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Renal Med, DK-8000 Aarhus, Denmark
关键词
e-health; cardiology; cardiovascular disease; telemedicine; telehealth; home health monitoring; AMERICAN-HEART-ASSOCIATION; HYPERTENSION; HOME; RECOMMENDATIONS; RELIABILITY; STATEMENT; ACCURATE; SOCIETY; ISSUES;
D O I
10.1089/tmj.2013.0032
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background:Patients with hypertension or receiving blood pressure (BP)-lowering treatment are often required to self-measure their BP in a dedicated self-measurement room before consultation. Current praxis does not guarantee valid measurements, possibly leading to misdiagnoses or inappropriate antihypertensive medication. The aim of this study was to investigate patients' ability to correctly self-report and follow recommendations.Patients and Methods:We used a context-aware system to gather information on BP measurements and relevant context parameters. Patients were not informed that the system automatically collected behavior data and were instructed to self-report their measurements on a paper sheet as usual. We then compared the automatically recorded data with the self-reported data in order to detect any nonadherent reporting behavior. Also, we investigated the patients' ability to adhere to the measurement recommendations.Results:We found that (1) a third of all 113 participating patients failed to self-report measured BP data correctly and (2) none of the 642 measurements obtained adhered fully to the recommendations.Conclusions:Results indicate that context-aware technology may be useful for accurately modeling aspects of nonadherent patient behavior. This may be used to inform staff of the validity of the measurement and pinpoint patients in need of additional training or to design better aids to assist the patients. The developed system is generally applicable to other self-measurement environments, including the home setting and remote outpatient clinics, as it is built using telemedicine technology and thus well suited for remote monitoring and diagnosis.
引用
收藏
页码:826 / 833
页数:8
相关论文
共 50 条
  • [1] Blood Pressure Self-Measurement in the Obstetric Waiting Room
    Wagner, Stefan
    Kamper, Christina H.
    Toftegaard, Thomas S.
    Bertelsen, Olav W.
    TELEMEDICINE AND E-HEALTH, 2013, 19 (11) : 872 - 874
  • [2] Reliable Blood Pressure Self-measurement in the Obstetric Waiting Room
    Wagner, S.
    Kamper, C. H.
    Rasmussen, N. H.
    Ahrendt, P.
    Toftegaard, T. S.
    Bertelsen, O. W.
    METHODS OF INFORMATION IN MEDICINE, 2014, 53 (03) : 225 - 234
  • [3] Blood Pressure Self-Measurement
    Wagner, Stefan
    HYPERTENSION: FROM BASIC RESEARCH TO CLINICAL PRACTICE, VOL 2, 2017, 956 : 97 - 107
  • [4] AUDIO CONTEXT CLASSIFICATION FOR DETERMINING BLOOD PRESSURE SELF-MEASUREMENT ADHERENCE
    Wagner, Stefan
    Ahrendt, Peter
    Toftegaard, Thomas S.
    Bertelsen, Olav W.
    PROCEEDINGS OF THE IADIS INTERNATIONAL CONFERENCE E-HEALTH 2012, 2012, : 105 - 114
  • [5] Effects of context-aware patient guidance on blood pressure self-measurement adherence levels
    Lindahl, Camilla
    Wagner, Stefan
    Uldbjerg, Niels
    Schlutter, Jacob Morup
    Bertelsen, Olav
    Sandager, Puk
    HEALTH INFORMATICS JOURNAL, 2019, 25 (02) : 417 - 428
  • [6] Effect of self-measurement of blood pressure on adherence to treatment in patients with mild-to-moderate hypertension
    van Onzenoort, Hein A. W.
    Verberk, Willem J.
    Kroon, Abraham A.
    Kessels, Alfons G. H.
    Nelemans, Patricia J.
    van der Kuy, Paul-Hugo M.
    Neef, Cees
    de Leeuw, Peter W.
    JOURNAL OF HYPERTENSION, 2010, 28 (03) : 622 - 627
  • [7] Context Assessment during Blood Pressure Self-measurement Utilizing the Sensor Chair
    Wagner, Stefan
    Toftegaard, Thomas Skjodeberg
    Bertelsen, Olav Wedege
    AMBIENT INTELLIGENCE, 2011, 7040 : 295 - +
  • [8] Automated blood pressure self-measurement station compared to office blood pressure measurement for first trimester screening of pre-eclampsia
    Holm, Louise
    Stucke-Brander, Tone
    Wagner, Stefan
    Sandager, Puk
    Schlutter, Jacob
    Lindahl, Camilla
    Uldbjerg, Niels
    HEALTH INFORMATICS JOURNAL, 2019, 25 (04) : 1815 - 1824
  • [9] CONTEXT-AWARE PATIENT GUIDANCE DURING BLOOD PRESSURE SELF-MEASUREMENT
    Sandager, P.
    Lindahl, C.
    Schlutter, J. M.
    Uldbjerg, N.
    Wagner, S.
    Toftegaard, T. S.
    Bertelsen, O. W.
    PROCEEDINGS OF THE IADIS INTERNATIONAL CONFERENCE E-HEALTH 2013, 2013, : 153 - 157
  • [10] Evaluation of Patient Adherence and Satisfaction with a Self-measurement Blood Pressure Telemonitoring Program
    Triventi, M.
    Calcagnini, G.
    Censi, F.
    Mattei, E.
    Strano, S.
    Bartolini, P.