Analysis the processing algorithm for the frequency measurement variance of the acousto-optic spectrum analyzer

被引:0
|
作者
He Qi-rui [1 ]
Gan Lu [1 ]
Zhou Ying [2 ]
Gao Chun-ming [2 ]
Zhang Xi-ren [2 ]
机构
[1] UESTC, Sch Elect Engn, Chengdu 611731, Peoples R China
[2] UESTC, Sch Optoelect Informat, Chengdu 610054, Peoples R China
关键词
Variance of measured error; Acousto-optic frequency measurement; Gaussian fitting method; squared cancroids method; Hilbert transform;
D O I
10.1117/12.2193254
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
When the acousto-optic device worked on the Bragg model, the non-liner affected the diffraction beam. There were some errors between the diffraction beam deflection peak position and the input signal's frequency, which reduced the frequency measure accuracy of the acousto-optic spectrum analyzer. Under the existing optical experimental platform, we eliminated the CCD background noise by reducing the threshold firstly, and then we processed the data by four methods, the peak value method, the Gaussian fitting method, the squared cancroids method and the Hilbert transform method. The least frequency measure variance is 31.8 KHz(2), the data processed by the Gaussian fitting method. It provides theoretical support for reducing the frequency measurement variance of acousto-optic spectrum analyzer.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Acousto-optic system for frequency and phase demodulation
    Hicks, M
    Reeve, CD
    ADVANCES IN OPTICAL INFORMATION PROCESSING VII, 1996, 2754 : 75 - 82
  • [32] AN ACOUSTO-OPTIC RECEIVER AND FAST SPECTRUM ANALYZER FOR ELECTROMAGNETIC SIGNALS IN VHF-UHF RANGE
    PARKS, JK
    IEEE TRANSACTIONS ON COMMUNICATION TECHNOLOGY, 1969, CO17 (06): : 686 - &
  • [33] Acoustic pressure measurement by acousto-optic tomography
    Remenieras, JP
    Matar, OB
    Calle, S
    Patat, F
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 505 - 508
  • [34] Acousto-optic low-frequency shifter
    Gazalet, M.G.
    Ravez, M.
    Haine, F.
    Bruneel, C.
    Bridoux, E.
    Applied Optics, 1994, 33 (07): : 1293 - 1298
  • [35] Cascade acousto-optic frequency shift of light
    Kotov, V
    Stiens, J
    Shkerdin, G
    Vounckx, R
    JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2001, 3 (06): : 517 - 520
  • [36] Tunable acousto-optic optical frequency combs
    Voloshin, Andrey
    Mantsevich, Sergey
    OPTICS LETTERS, 2022, 47 (17) : 4540 - 4543
  • [37] Acousto-optic frequency combs for heterodyne interferometry
    Duran, V.
    Schnebelin, C.
    de Chatellus, H. Guillet
    2017 XXXIIND GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM OF THE INTERNATIONAL UNION OF RADIO SCIENCE (URSI GASS), 2017,
  • [38] Scanning Velocity Measurement of an Acousto-Optic Deflector
    Amir Guessoum
    Optics and Spectroscopy, 2019, 126 : 443 - 449
  • [39] Depth selective acousto-optic flow measurement
    Tsalach, Adi
    Schiffer, Zeev
    Ratner, Eliahu
    Breskin, Ilan
    Zeitak, Reuven
    Shechter, Revital
    Balberg, Michal
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (12): : 4871 - 4886
  • [40] Scanning Velocity Measurement of an Acousto-Optic Deflector
    Guessoum, Amir
    OPTICS AND SPECTROSCOPY, 2019, 126 (04) : 443 - 449