Experience with early TEVAR treatment of uncomplicated type B aortic dissection

被引:0
作者
Lin, J. [1 ]
Marrocco, C. [1 ]
Galovich, J. [1 ]
Kopchok, G. [1 ]
Khoynezhad, A. [1 ,2 ,3 ]
Walot, I. [4 ]
Haji, F. [1 ]
Jaber, R. [1 ]
Donayre, C. [1 ]
White, R. [1 ]
机构
[1] Harbor UCLA Med Ctr, Div Vasc Surg, Torrance, CA 90502 USA
[2] Harbor UCLA Med Ctr, Div Cardiothorac Surg, Torrance, CA 90502 USA
[3] Cedars Sinai Med Ctr, Div Cardiothorac Surg, Los Angeles, CA 90048 USA
[4] Harbor UCLA Med Ctr, Dept Radiol, Torrance, CA 90502 USA
关键词
Stents; Endovascular procedures; Aortic valve; STENT-GRAFT PLACEMENT; ENDOVASCULAR TREATMENT; HYBRID PROCEDURES; ANEURYSM REPAIR; THORACIC AORTA; FLUID DRAINAGE; A DISSECTION; FALSE LUMEN; OUTCOMES; MANAGEMENT;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The current paradigm for the treatment of chronic type B aortic dissection involves primarily medical treatment. The patients are then followed for sequelae like progressive dissection or aneurysmal degeneration, selecting this subgroup for further intervention. The European Collaborator Registry, the Talent Thoracic Retrospective Registry, and several meta-analysis showed that the uncomplicated type B dissection patients who underwent thoracic endovascular aortic repair (TEVAR) outperformed their counterpart in the complicated group. The INSTEAD trial, the first randomized trial to examine whether TEVAR is better than medical management in the chronic stable dissection patients, showed no benefit early on although mid-term data might show some benefit. Clearly more randomized controlled trials are necessary to create a paradigm shift. In the United States, the FDA approved TEVAR devices are for the descending thoracic aortic aneurysm and transection only. The use of these devices for dissection is off-label or for investigation only. As future study might broaden the use of TEVAR for the chronic dissection patients, the use of TEVAR in hybrid surgery and in the ascending aorta is also broadening the indication for this technology. With two decades of innovation behind, TEVAR will continue to evolve and innovate in the years ahead.
引用
收藏
页码:161 / 171
页数:11
相关论文
共 57 条
[11]   Endovascular stent-graft placement for the treatment of acute aortic dissection [J].
Dake, MD ;
Kato, N ;
Mitchell, RS ;
Semba, CP ;
Razavi, MK ;
Shimono, T ;
Hirano, T ;
Takeda, K ;
Yada, I ;
Miller, DC .
NEW ENGLAND JOURNAL OF MEDICINE, 1999, 340 (20) :1546-1552
[12]   TRANSLUMINAL PLACEMENT OF ENDOVASCULAR STENT-GRAFTS FOR THE TREATMENT OF DESCENDING THORACIC AORTIC-ANEURYSMS [J].
DAKE, MD ;
MILLER, DC ;
SEMBA, CP ;
MITCHELL, RS ;
WALKER, PJ ;
LIDDELL, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (26) :1729-1734
[13]   The "first generation" of endovascular stent-grafts for patients with aneurysms of the descending thoracic aorta [J].
Dake, MD ;
Miller, DC ;
Mitchell, RS ;
Semba, CP ;
Moore, KA ;
Sakai, T .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 116 (05) :689-703
[14]   Midterm results of endovascular repair of descending thoracic aortic aneurysms with first-generation stent grafts [J].
Demers, P ;
Miller, DC ;
Mitchell, RS ;
Kee, ST ;
Sze, D ;
Razavi, MK ;
Dake, MD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (03) :664-673
[15]   Thoracic endovascular aortic repair: Evolution of therapy, patterns of use, and results in a 10-year experience [J].
Desai, Nimesh D. ;
Pochettino, Alberto ;
Szeto, Wilson Y. ;
Moser, G. William ;
Moeller, Patrick J. ;
Sodhi, Nishtha ;
Jackson, Benjamin ;
Woo, Edward ;
Fairman, Ronald M. ;
Bavaria, Joseph .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2011, 142 (03) :587-594
[16]   Stent graft-induced new entry after endovascular repair for Stanford type B aortic dissection [J].
Dong, Zhihui ;
Fu, Weiguo ;
Wang, Yuqi ;
Wang, Chunsheng ;
Yan, Zhiping ;
Guo, Daqiao ;
Xu, Xin ;
Chen, Bin .
JOURNAL OF VASCULAR SURGERY, 2010, 52 (06) :1450-1457
[17]  
Eagleton MJ, 2010, J CARDIOVASC SURG, V51, P807
[18]   Endovascular stent-graft placement in aortic dissection:: a meta-analysis [J].
Eggebrecht, H ;
Nienaber, CA ;
Neuhäuser, M ;
Baumgart, D ;
Kische, S ;
Schmermund, A ;
Herold, U ;
Rehders, TC ;
Jakob, HG ;
Erbel, R .
EUROPEAN HEART JOURNAL, 2006, 27 (04) :489-498
[19]   Retrograde Ascending Aortic Dissection During or After Thoracic Aortic Stent Graft Placement Insight From the European Registry on Endovascular Aortic Repair Complications [J].
Eggebrecht, Holger ;
Thompson, Matt ;
Rousseau, Herve ;
Czerny, Martin ;
Loenn, Lars ;
Mehta, Rajendra H. ;
Erbel, Raimund .
CIRCULATION, 2009, 120 (11) :S276-S281
[20]   Cerebrospinal Fluid Drainage During Thoracic Aortic Repair: Safety and Current Management [J].
Estrera, Anthony L. ;
Sheinbaum, Roy ;
Miller, Charles C. ;
Azizzadeh, Ali ;
Walkes, Jon-Cecil ;
Lee, Taek-Yeon ;
Kaiser, Larry ;
Safi, Hazim J. .
ANNALS OF THORACIC SURGERY, 2009, 88 (01) :9-15