Changes in pore morphology and fluid transport in compressed articular cartilage and the implications for joint lubrication

被引:37
作者
Greene, George W. [2 ]
Zappone, Bruno [1 ,3 ,4 ]
Zhao, Boxin [1 ]
Soderman, Olle [5 ]
Topgaard, Daniel [5 ]
Rata, Gabriel [5 ]
Israelachvili, Jacob N. [1 ,2 ]
机构
[1] Univ Calif Santa Barbara, Dept Chem Engn, Santa Barbara, CA 93106 USA
[2] Univ Calif Santa Barbara, Dept Mat, Santa Barbara, CA 93106 USA
[3] Univ Calabria, LiCryL CNR INFM, I-87036 Arcavacata Di Rende, Italy
[4] Univ Calabria, CemifCal, I-87036 Arcavacata Di Rende, Italy
[5] Lund Univ, Ctr Chem, S-22100 Lund, Sweden
关键词
Cartilage; Fluorescence recovery after photobleaching; FRAP; Pulse-gradient NMR; Collagen structure; Joint lubrication;
D O I
10.1016/j.biomaterials.2008.07.046
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cartilage sections were cut from the middle zone of pig knee articular cartilage and attached to substrates in two different kinds of newly designed 'pressure cells', one for fluorescence the other for NMR measurements, The fluorescence cell was filled with buffer solution containing fluorescently marked 70 kDa dextran which was allowed to diffuse into the cartilage pores. A second glass surface was then pressed down onto the thin cartilage sample under different loads (pressures), and the resulting compression (strain) and change in pore volume were measured as a function of time, simultaneously with measurements of the lateral diffusion and flow pattern of the dextran molecules using Fluorescence Recovery After Photobleaching (FRAP). Complementary experiments were made on the normal diffusion coefficients of pure electrolyte solutions (no dextran) in thicker cartilage sections with pulse-gradient NMR using a new pressure cell suitable for such measurements. Taken together our results show that the highly anisotropic structure of cartilage has a strong effect on the way fluid diffuses laterally and normally at different stages of compression. Our results also show how geometric constraints on a cartilage network and trapped high MW polymer such as HA during normal compressions are likely to affect both the normal and the lateral mobilities of polyelectrolytes and water. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4455 / 4462
页数:8
相关论文
共 40 条
[1]  
ap Gwynn I., 2002, European Cells & Materials, V4, P18
[2]   MOBILITY MEASUREMENT BY ANALYSIS OF FLUORESCENCE PHOTOBLEACHING RECOVERY KINETICS [J].
AXELROD, D ;
KOPPEL, DE ;
SCHLESSINGER, J ;
ELSON, E ;
WEBB, WW .
BIOPHYSICAL JOURNAL, 1976, 16 (09) :1055-1069
[3]  
Benninghoff, 1925, Z ZELLFORSCH, V2, P783, DOI [DOI 10.1007/BF00583443, 10.1007/BF00583443]
[4]   Lubrication and wear properties of grafted polyelectrolytes, hyaluronan and hylan, measured in the surface forces apparatus [J].
Benz, M ;
Chen, NH ;
Israelachvili, J .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2004, 71A (01) :6-15
[5]   Amontons' law at the molecular level [J].
Berman, Alan ;
Drummond, Carlos ;
Israelachvili, Jacob .
TRIBOLOGY LETTERS, 1998, 4 (02) :95-101
[6]  
BLUMICH B, 2000, NMR IMAGING MAT, P211
[7]  
BULLOUGH P, 1968, Journal of Bone and Joint Surgery British Volume, V50-B, P852
[8]   DIFFUSION OF SMALL SOLUTES IN CARTILAGE AS MEASURED BY NUCLEAR-MAGNETIC-RESONANCE (NMR) SPECTROSCOPY AND IMAGING [J].
BURSTEIN, D ;
GRAY, ML ;
HARTMAN, AL ;
GIPE, R ;
FOY, BD .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1993, 11 (04) :465-478
[9]  
CALLAGHAN PT, 1991, PRINCIPLES NUCL MAGN, P162
[10]   Depth- and strain-dependent mechanical and electromechanical properties of full-thickness bovine articular cartilage in confined compression [J].
Chen, AC ;
Bae, WC ;
Schinagl, RM ;
Sah, RL .
JOURNAL OF BIOMECHANICS, 2001, 34 (01) :1-12