The reliability of MEMS sensors or actuators such as accelerometers, gyroscopes, resonators, RF switches, microbolometers... is critically dependent on the vacuum level and on the nature of the gaseous species present inside the MEMS cavity (similar to 1 mm(3) or less, usually in the 10(-2)-10(-3) mbar vacuum range after sealing by Wafer Level Packaging process). Although a lot of methods have been explored, the Residual Gas Analysis (RGA) method - however destructive-reveals to be an interesting technique to determine the possible sources of gaseous species present in the MEMS cavity or outgassed by materials, in order to assess to which extent a given packaging technology is capable of maintaining the required environmental conditions all along the device lifetime. This paper introduces results recently achieved with two specifics RGA test benches developed at CEA-LETI (i) to analyze very small amounts of gases trapped inside MEMS cavities, and (ii) to assess the out-gassing or pumping behavior of bulk or getter materials. These Ultra High Vacuum (UHV) RGA equipments operate with a residual background pressure level in the 10(-10) mbar range and use Quadripolar Mass Spectrometers (QMS) for gas analysis. Experimental results confirm that the RGA technique is successfully used to identify the nature and proportions of gases outgassed by materials or trapped in cavities as small as 1 mm(3) under a residual pressure lower than 10(-2) mbar. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1622 / 1627
页数:6
相关论文
共 6 条
  • [1] Chidambaram V, 2012, J ELECT MAT
  • [2] De Wolf I, 2007, IPFA 2007: PROCEEDINGS OF THE 14TH INTERNATIONAL SYMPOSIUM ON THE PHYSICAL & FAILURE ANALYSIS OF INTEGRATED CIRCUITS, P147
  • [3] In situ ultrahigh vacuum residual gas analyzer "calibration"
    Malyshev, O. B.
    Middleman, K. J.
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2008, 26 (06): : 1474 - 1479
  • [4] Review of vacuum packaging and maintenance of MEMS and the use of getters therein
    Ramesham, Rajeshuni
    Kullberg, Richard C.
    [J]. JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2009, 8 (03):
  • [5] Rapp D., 1965, J CHEM PHYS, V43
  • [6] Savornin B, 2013, P 63 IEEE EL COMP TE