Microscopic anisotropy misestimation in spherical-mean single diffusion encoding MRI

被引:51
|
作者
Henriques, Rafael Neto [1 ]
Jespersen, Sune N. [2 ,3 ,4 ]
Shemesh, Noam [1 ]
机构
[1] Champalimaud Ctr Unknown, Champalimaud Neurosci Programme, Av Brasilia, P-1400038 Lisbon, Portugal
[2] Aarhus Univ, CFIN, Aarhus, Denmark
[3] Aarhus Univ, Clin Inst, MINDLab, Aarhus, Denmark
[4] Aarhus Univ, Dept Phys & Astron, Aarhus, Denmark
基金
欧盟地平线“2020”; 欧洲研究理事会;
关键词
double diffusion encoding; diffusion kurtosis; diffusion MRI; diffusion tensor; microscopic fractional anisotropy; single diffusion encoding; spherical mean technique; COMPARTMENT SHAPE ANISOTROPY; WHITE-MATTER; ORIENTATION DISPERSION; TISSUE-MICROSTRUCTURE; RESTRICTED DIFFUSION; WATER DIFFUSION; ENSEMBLE ANISOTROPY; AXON DIAMETER; FIELD; TENSOR;
D O I
10.1002/mrm.27606
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Microscopic fractional anisotropy (mu FA) can disentangle microstructural information from orientation dispersion. While double diffusion encoding (DDE) MRI methods are widely used to extract accurate mu FA, it has only recently been proposed that powder-averaged single diffusion encoding (SDE) signals, when coupled with the diffusion standard model (SM) and a set of constraints, could be used for mu FA estimation. This study aims to evaluate mu FA as derived from the spherical mean technique (SMT) set of constraints, as well as more generally for powder-averaged SM signals. Methods: SDE experiments were performed at 16.4 T on an ex vivo mouse brain (Delta/delta = 12/1.5 ms). The mu FA maps obtained from powder-averaged SDE, signals were then compared to maps obtained from DDE-MRI experiments (Delta/tau/delta = 12/12/1.5 ms), which allow a model-free estimation of mu FA. Theory and simulations that consider different types of heterogeneity are presented for corroborating the experimental findings. Results: mu FA, as well as other estimates derived from powder-averaged SDE signals produced large deviations from the ground truth in both gray and white matter. Simulations revealed that these misestimations are likely a consequence of factors not considered by the underlying microstructural models (such as intercomponent and intracompartmental kurtosis). Conclusion: Powder-averaged SMT and (2-component) SM are unable to accurately report mu FA and other microstructural parameters in ex vivo tissues. Improper model assumptions and constraints can significantly compromise parameter specificity. Further developments and validations are required prior to implementation of these models in clinical or preclinical research.
引用
收藏
页码:3245 / 3261
页数:17
相关论文
共 28 条
  • [21] Tissue Segmentation Using Sparse Non-negative Matrix Factorization of Spherical Mean Diffusion MRI Data
    Sun, Peng
    Wu, Ye
    Chen, Geng
    Wu, Jun
    Shen, Dinggang
    Yap, Pew-Thian
    COMPUTATIONAL DIFFUSION MRI (CDMRI 2018), 2019, : 69 - 76
  • [22] Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI
    Wilm, Bertram J.
    Barmet, Christoph
    Gross, Simon
    Kasper, Lars
    Vannesjo, S. Johanna
    Haeberlin, Max
    Dietrich, Benjamin E.
    Brunner, David O.
    Schmid, Thomas
    Pruessmann, Klaas P.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (01) : 83 - 91
  • [23] Single- and Mutiple-Shell Uniform Sampling Schemes for Diffusion MRI Using Spherical Codes
    Cheng, Jian
    Shen, Dinggang
    Yap, Pew-Thian
    Basser, Peter J.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (01) : 185 - 199
  • [24] Tensor-valued diffusion MRI in under 3 minutes: an initial survey of microscopic anisotropy and tissue heterogeneity in intracranial tumors
    Nilsson, Markus
    Szczepankiewicz, Filip
    Brabec, Jan
    Taylor, Marie
    Westin, Carl-Fredrik
    Golby, Alexandra
    van Westen, Danielle
    Sundgren, Pia C.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) : 608 - 620
  • [25] Diffusion tensor subspace imaging of double diffusion-encoded MRI delineates small fibers and gray-matter microstructure not visible with single encoding techniques
    Hutchinson, Elizabeth B.
    Galons, Jean-Philippe
    Comrie, Courtney J.
    Beach, Thomas G.
    Serrano, Geidy E.
    Bondi, Mark W.
    Solders, Seraphina K.
    Galinsky, Vitaly L.
    Frank, Lawrence R.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (06) : 2370 - 2385
  • [26] Non-Negative Spherical Deconvolution (NNSD) for estimation of fiber Orientation Distribution Function in single-/multi-shell diffusion MRI
    Cheng, Jian
    Deriche, Rachid
    Jiang, Tianzi
    Shen, Dinggang
    Yap, Pew-Thian
    NEUROIMAGE, 2014, 101 : 750 - 764
  • [27] Mean diffusivity, fractional anisotropy maps, and three-dimensional white-matter tractography by diffusion tensor imaging. Comparison between single-shot fast spin-echo and single-shot echo-planar sequences at 1.5 Tesla
    Masaaki Hori
    Keiichi Ishigame
    Nobuyuki Shiraga
    Hiroshi Kumagai
    Shigeki Aoki
    Tsutomu Araki
    European Radiology, 2008, 18 : 830 - 834
  • [28] Mean diffusivity, fractional anisotropy maps, and three-dimensional white-matter tractography by diffusion tensor imaging. Comparison between single-shot fast spin-echo and single-shot echo-planar sequences at 1.5 Tesla
    Hori, Masaaki
    Ishigame, Keiichi
    Shiraga, Nobuyuki
    Kumagai, Hiroshi
    Aoki, Shigeki
    Araki, Tsutomu
    EUROPEAN RADIOLOGY, 2008, 18 (04) : 830 - 834