共 28 条
Microscopic anisotropy misestimation in spherical-mean single diffusion encoding MRI
被引:51
|作者:
Henriques, Rafael Neto
[1
]
Jespersen, Sune N.
[2
,3
,4
]
Shemesh, Noam
[1
]
机构:
[1] Champalimaud Ctr Unknown, Champalimaud Neurosci Programme, Av Brasilia, P-1400038 Lisbon, Portugal
[2] Aarhus Univ, CFIN, Aarhus, Denmark
[3] Aarhus Univ, Clin Inst, MINDLab, Aarhus, Denmark
[4] Aarhus Univ, Dept Phys & Astron, Aarhus, Denmark
基金:
欧盟地平线“2020”;
欧洲研究理事会;
关键词:
double diffusion encoding;
diffusion kurtosis;
diffusion MRI;
diffusion tensor;
microscopic fractional anisotropy;
single diffusion encoding;
spherical mean technique;
COMPARTMENT SHAPE ANISOTROPY;
WHITE-MATTER;
ORIENTATION DISPERSION;
TISSUE-MICROSTRUCTURE;
RESTRICTED DIFFUSION;
WATER DIFFUSION;
ENSEMBLE ANISOTROPY;
AXON DIAMETER;
FIELD;
TENSOR;
D O I:
10.1002/mrm.27606
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: Microscopic fractional anisotropy (mu FA) can disentangle microstructural information from orientation dispersion. While double diffusion encoding (DDE) MRI methods are widely used to extract accurate mu FA, it has only recently been proposed that powder-averaged single diffusion encoding (SDE) signals, when coupled with the diffusion standard model (SM) and a set of constraints, could be used for mu FA estimation. This study aims to evaluate mu FA as derived from the spherical mean technique (SMT) set of constraints, as well as more generally for powder-averaged SM signals. Methods: SDE experiments were performed at 16.4 T on an ex vivo mouse brain (Delta/delta = 12/1.5 ms). The mu FA maps obtained from powder-averaged SDE, signals were then compared to maps obtained from DDE-MRI experiments (Delta/tau/delta = 12/12/1.5 ms), which allow a model-free estimation of mu FA. Theory and simulations that consider different types of heterogeneity are presented for corroborating the experimental findings. Results: mu FA, as well as other estimates derived from powder-averaged SDE signals produced large deviations from the ground truth in both gray and white matter. Simulations revealed that these misestimations are likely a consequence of factors not considered by the underlying microstructural models (such as intercomponent and intracompartmental kurtosis). Conclusion: Powder-averaged SMT and (2-component) SM are unable to accurately report mu FA and other microstructural parameters in ex vivo tissues. Improper model assumptions and constraints can significantly compromise parameter specificity. Further developments and validations are required prior to implementation of these models in clinical or preclinical research.
引用
收藏
页码:3245 / 3261
页数:17
相关论文