Radial simultaneous multi-slice CAIPI for ungated myocardial perfusion
被引:24
作者:
Wang, Haonan
论文数: 0引用数: 0
h-index: 0
机构:
Brigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USABrigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
Wang, Haonan
[1
]
Adluru, Ganesh
论文数: 0引用数: 0
h-index: 0
机构:
Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USABrigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
Adluru, Ganesh
[2
]
Chen, Liyong
论文数: 0引用数: 0
h-index: 0
机构:
Adv MRI Technol, Sebastopol, CA USABrigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
Chen, Liyong
[3
]
Kholmovski, Eugene G.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USABrigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
Kholmovski, Eugene G.
[2
]
Bangerter, Neal K.
论文数: 0引用数: 0
h-index: 0
机构:
Brigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USABrigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
Bangerter, Neal K.
[1
,2
]
DiBella, Edward V. R.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USABrigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
DiBella, Edward V. R.
[2
]
机构:
[1] Brigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
[2] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USA
Objective: Simultaneous multi-slice (SMS) imaging is a slice acceleration technique that acquires multiple slices in the same time as a single slice. Radial controlled aliasing in parallel imaging results in higher acceleration (radial CAIPIRINHA or CAIPI) is a promising SMS method with less severe slice aliasing artifacts as compared to its Cartesian counterpart. Here we use radial CAIPI with data undersampling and constrained reconstruction to improve the utility of ungated cardiac perfusion acquisitions. We test the proposed framework with a traditional saturation recovery fast low-angle shot (turboFLASH) sequence and also without saturation recovery as a steady-state spoiled gradient echo (SPGR) sequence on animal and human studies. Methods: Simulations and phantom studies were performed for both the turboFLASH and the SPGR radial CAIPI methods. Ungated undersampled golden ratio radial CAIPI data with saturation recovery were acquired in 8 dogs and 2 human subjects. The CAIPI data without saturation pulses were acquired in 4 human subjects. For both methods, slice acceleration factors of two and three were used. A new spatio-temporal reconstruction using total variation and patch-based low rank constraints was used to jointly reconstruct the multi-slice multi-coil images. Results: Phantom scans and computer simulations showed that ungated SPGR generally provides better contrast to noise ratio (CNR) than the saturation recovery sequence if the saturation recovery time is less than 100 ms. Both of the ungated radial CAIPI methods demonstrated promising image quality in terms of preserving dynamics of the contrast agent and maintaining anatomical structures, even with three slices acquired simultaneously. Conclusion: Ungated simultaneous multi-slice acquisitions with either a saturation recovery turboFLASH sequence or a steady-state gradient echo SPGR sequence are feasible and provide increased slice coverage without loss of temporal resolution. Compared with a sensitivity encoding (SENSE) SMS reconstruction, the constrained reconstruction method provides better image quality for undersampled radial CAIPI data. (C) 2016 Elsevier Inc. All rights reserved.