Radial simultaneous multi-slice CAIPI for ungated myocardial perfusion

被引:24
作者
Wang, Haonan [1 ]
Adluru, Ganesh [2 ]
Chen, Liyong [3 ]
Kholmovski, Eugene G. [2 ]
Bangerter, Neal K. [1 ,2 ]
DiBella, Edward V. R. [2 ]
机构
[1] Brigham Young Univ, Dept Elect & Comp Engn, Provo, UT 84602 USA
[2] Univ Utah, Dept Radiol & Imaging Sci, Salt Lake City, UT USA
[3] Adv MRI Technol, Sebastopol, CA USA
关键词
Myocardial perfusion; Simultaneous multi-slice; CAIPIRINHA; Non-Cartesian; Compressed sensing; CARDIOVASCULAR MAGNETIC-RESONANCE; 1ST-PASS CARDIAC PERFUSION; MRI; RECONSTRUCTION; ACQUISITION; SEQUENCES;
D O I
10.1016/j.mri.2016.07.015
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Simultaneous multi-slice (SMS) imaging is a slice acceleration technique that acquires multiple slices in the same time as a single slice. Radial controlled aliasing in parallel imaging results in higher acceleration (radial CAIPIRINHA or CAIPI) is a promising SMS method with less severe slice aliasing artifacts as compared to its Cartesian counterpart. Here we use radial CAIPI with data undersampling and constrained reconstruction to improve the utility of ungated cardiac perfusion acquisitions. We test the proposed framework with a traditional saturation recovery fast low-angle shot (turboFLASH) sequence and also without saturation recovery as a steady-state spoiled gradient echo (SPGR) sequence on animal and human studies. Methods: Simulations and phantom studies were performed for both the turboFLASH and the SPGR radial CAIPI methods. Ungated undersampled golden ratio radial CAIPI data with saturation recovery were acquired in 8 dogs and 2 human subjects. The CAIPI data without saturation pulses were acquired in 4 human subjects. For both methods, slice acceleration factors of two and three were used. A new spatio-temporal reconstruction using total variation and patch-based low rank constraints was used to jointly reconstruct the multi-slice multi-coil images. Results: Phantom scans and computer simulations showed that ungated SPGR generally provides better contrast to noise ratio (CNR) than the saturation recovery sequence if the saturation recovery time is less than 100 ms. Both of the ungated radial CAIPI methods demonstrated promising image quality in terms of preserving dynamics of the contrast agent and maintaining anatomical structures, even with three slices acquired simultaneously. Conclusion: Ungated simultaneous multi-slice acquisitions with either a saturation recovery turboFLASH sequence or a steady-state gradient echo SPGR sequence are feasible and provide increased slice coverage without loss of temporal resolution. Compared with a sensitivity encoding (SENSE) SMS reconstruction, the constrained reconstruction method provides better image quality for undersampled radial CAIPI data. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:1329 / 1336
页数:8
相关论文
共 37 条
  • [1] Adluru G, 2015, P 23 ANN M ISMRM TOR
  • [2] Adluru G, 2014, P 22 ANN M ISMRM MIL
  • [3] Acquisition and Reconstruction of Undersampled Radial Data for Myocardial Perfusion Magnetic Resonance Imaging
    Adluru, Ganesh
    McGann, Chris
    Speier, Peter
    Kholmovski, Eugene G.
    Shaaban, Akrarn
    DiBella, Edward V. R.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) : 466 - 473
  • [4] [Anonymous], J CARDIOVASC MAGN S1
  • [5] 1ST-PASS CARDIAC PERFUSION - EVALUATION WITH ULTRAFAST MR IMAGING
    ATKINSON, DJ
    BURSTEIN, D
    EDELMAN, RR
    [J]. RADIOLOGY, 1990, 174 (03) : 757 - 762
  • [6] Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging
    Breuer, FA
    Blaimer, M
    Heidemann, RM
    Mueller, MF
    Griswold, MA
    Jakob, PM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) : 684 - 691
  • [7] Quantification of myocardial blood flow using non-electrocardiogram-triggered MRI with three-slice coverage
    Chen, David
    Sharif, Behzad
    Bi, Xiaoming
    Wei, Janet
    Thomson, Louise E. J.
    Merz, C. Noel Bairey
    Berman, Daniel S.
    Li, Debiao
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (05) : 2112 - 2120
  • [8] Myocardial perfusion MRI with an undersampled 3D stack-of-stars sequence
    Chen, Liyong
    Adluru, Ganesh
    Schabel, Matthias C.
    McGann, Chris J.
    DiBella, Edward V. R.
    [J]. MEDICAL PHYSICS, 2012, 39 (08) : 5204 - 5211
  • [9] Myocardial perfusion acquisition without magnetization preparation or gating
    DiBella, Edward V. R.
    Chen, Liyong
    Schabel, Matthias C.
    Adluru, Ganesh
    McGann, Chris J.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2012, 67 (03) : 609 - 613
  • [10] Compressed sensing
    Donoho, DL
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2006, 52 (04) : 1289 - 1306