Micro-CT assessment of two different endodontic preparation systems

被引:9
作者
Moura-Netto, Cacio [1 ]
Palo, Renato Miotto [2 ]
Ribeiro Camargo, Carlos Henrique [2 ]
Pameijer, Cornelis Hans [3 ]
Ramalho da Silva Bardauil, Marcia Regina [4 ]
机构
[1] Univ Cruzeiro Sul UNICSUL, Sch Dent, Dept Endodont, Sao Paulo, Brazil
[2] Univ Estadual Paulista UNESP, Sch Dent, Dept Endodont, Sao Jose Dos Campos, SP, Brazil
[3] Univ Connecticut Hlth Ctr, Sch Dent, Dept Endodont, Farmington, CT USA
[4] Univ Paulista UNIP, Sch Dent, Dept Biochem, Sao Paulo, Brazil
关键词
Dental Pulp Cavity; Root Canal Therapy; Endodontics; ROOT-CANAL PREPARATION; COMPUTED TOMOGRAPHY; MICROCOMPUTED TOMOGRAPHY; CYCLIC FATIGUE; ROTARY FILES; INSTRUMENTATION; PROTAPER; RESISTANCE; PROFILE; ENDO;
D O I
10.1590/S1806-83242012005000029
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this study was to compare two endodontic preparation systems using micro-CT analysis. Twenty-four one-rooted mandibular premolars were selected and randomly assigned to two groups. The samples (n = 12) of Group 1 were prepared using the Pro Taper Universal rotary system, while Group 2 (n = 12) was prepared using the EndoEZE AET system complemented by manual apical preparation with K-type hand files up to #30. A 2.5% sodium hypochlorite solution was. used in both groups for irrigating. Both groups were scanned by high-resolution microcomputed tomography before and after preparation (Sky Scan 1172, Sky Scan, Kontich, Belgium). The root canal volume and surface area was measured before and after preparation, and the differences were calculated and analyzed for statistically significant differences using ANOVA complemented by the Tukey test (p < 0.05). The results showed no statistically significant differences between the mean volumes of dentin removal by the two systems However, the EndoEZE AET system presented a significantly greater mean surface area compared to the Pro Taper system (p < 0.05). The EndoEZE AET system enabled preparation of a greater root canal surface area when compared to the Pro Taper Universal system. There seemed to be no difference in dentin volume loss between the two systems used.
引用
收藏
页码:26 / 30
页数:5
相关论文
共 50 条
[21]   Exploring the Efficacy of 6 Preparation Systems for Achieving Minimal Root Canal Transportation: A Micro-CT Investigation [J].
Belladonna, Felipe Goncalves ;
Guimaraes, Tiago de Mello ;
Silva, Emmanuel Joao Nogueira Leal ;
Vieira, Esio de Oliveira ;
Lee, Jong-Ki ;
Rodrigues, Evaldo de Almeida ;
Souza, Erick Miranda ;
Versiani, Marco Aurelio .
JOURNAL OF ENDODONTICS, 2023, 49 (12) :1722-1732
[22]   Effectiveness and safety of three NiTi systems in endodontic retreatment of MB1 and MB2 root canals: a micro-CT and CBCT combined analysis [J].
Santos Jr, Airton Oliveira ;
Fontenele, Rocharles Cavalcante ;
Tavares, Karina Ines Medina Carita ;
Torres, Fernanda Ferrari Esteves ;
Pinto, Jader Camilo ;
Rosim, Pedro Luis Busto ;
Goncalves, Andrea ;
Duarte, Marco Antonio Hungaro ;
Guerreiro-Tanomaru, Juliane Maria ;
Tanomaru-Filho, Mario .
CLINICAL ORAL INVESTIGATIONS, 2025, 29 (04)
[23]   Body fat of rats of different age groups and nutritional states: assessment by micro-CT and skinfold thickness [J].
Tekus, Eva ;
Miko, Alexandra ;
Furedi, Nora ;
Rostas, Ildiko ;
Tenk, Judit ;
Kiss, Tamas ;
Szitter, Istvan ;
Balasko, Marta ;
Helyes, Zsuzsanna ;
Wilhelm, Marta ;
Petervari, Erika .
JOURNAL OF APPLIED PHYSIOLOGY, 2018, 124 (02) :268-275
[24]   Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging [J].
Namati, Eman ;
Thiesse, Jacqueline ;
Sieren, Jessica C. ;
Ross, Alan ;
Hoffman, Eric A. ;
McLennan, Geoffrey .
MEDICAL PHYSICS, 2010, 37 (09) :4793-4805
[25]   Spectral optimization for micro-CT [J].
Hupfer, Martin ;
Nowak, Tristan ;
Brauweiler, Robert ;
Eisa, Fabian ;
Kalender, Willi A. .
MEDICAL PHYSICS, 2012, 39 (06) :3229-3239
[26]   Comparison of root canal shaping ability of different heat-treated NiTi single files: a micro-CT study [J].
Bal, Emine Zeynep ;
Gunes, Betul ;
Bayrakdar, Ibrahim Sevki .
QUINTESSENCE INTERNATIONAL, 2022, 53 (02) :112-121
[27]   Comparison of endodontic obturation by lateral condensation techniques, hybrid Tagger and Thermafil: a pilot study with Micro-CT [J].
Martins, Sofia Cesar ;
Mello, Joao ;
Martins, Claudia Cavaco ;
Mauricio, Antonio ;
Ginjeira, Antonio .
REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2011, 52 (02) :59-69
[28]   A Micro-CT Analysis of Initial and Long-Term Pores Volume and Porosity of Bioactive Endodontic Sealers [J].
Radwanski, Mateusz ;
Leski, Michal ;
Puszkarz, Adam K. ;
Sokolowski, Jerzy ;
Hardan, Louis ;
Bourgi, Rim ;
Sauro, Salvatore ;
Lukomska-Szymanska, Monika .
BIOMEDICINES, 2022, 10 (10)
[29]   Presentation of gaps around endodontic access cavity restoration by phase contrast-enhanced micro-CT [J].
Kriznar, Igor ;
Zanini, Franco ;
Fidler, Ales .
CLINICAL ORAL INVESTIGATIONS, 2019, 23 (05) :2371-2381
[30]   Micro-Computed Tomography (Micro-CT) Evaluation of Effects of Different Rotary Glide Path Techniques on Canal Transportation and Centering in Curved Root Canals [J].
Cesaitiene, Gabriele ;
Venskutonis, Tadas ;
Maciulskiene, Vita ;
Cicenas, Vaidotas ;
Samaitis, Vykintas ;
Jasiuniene, Elena .
MEDICAL SCIENCE MONITOR, 2019, 25 :6351-6358