Preconcentration of morphine and codeine using a magnetite/reduced graphene oxide/silver nano-composite and their determination by high-performance liquid chromatography

被引:34
作者
Abdolmohammad-Zadeh, Hossein [1 ]
Zamani, Abbasali [2 ]
Shamsi, Zahra [1 ]
机构
[1] Azarbaijan Shahid Madani Univ, Fac Sci, Dept Chem, Analyt Spect Res Lab, 35 Km Tabriz Marageh Rd,POB 53714-161, Tabriz 5375171379, Iran
[2] Univ Zanjan, Fac Sci, Dept Environm Sci, Zanjan 4537138791, Iran
关键词
Morphine; Codeine; Fe3O4/reduced graphene oxide/Ag nano-composite; Magnetic solid-phase extraction; Response surface methodology; Opioids; SOLID-PHASE EXTRACTION; ILLICIT DRUGS; URINE SAMPLES; METABOLITES; SURFACE; METHAMPHETAMINE; NANOCOMPOSITES; NANOPARTICLES; OPIATES; OPIOIDS;
D O I
10.1016/j.chroma.2018.12.064
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel magnetic solid-phase extraction technique based on a ternary nano-composite, magnetite/reduced graphene oxide/silver, as a nano-sorbent was developed for simultaneous extraction/preconcentration and measurement of morphine and codeine in biological samples by high-performance liquid chromatography. The magnetic ternary nano-composite was synthesized and its functional groups, morphological structure, and magnetic properties were characterized by field emission scanning electron microscopy, vibrating sample magnetometer, powder X-ray diffraction, energy dispersive X-ray spectroscopy and Fourier transform infrared spectroscopy. The optimizing of the significant variables affecting the extraction process was evaluated by a response surface methodology. In the optimized conditions, the constructed calibration curves for morphine and codeine are linear in the range of 0.01-10 mu g L-1 with correlation coefficients of 0.9983 and 0.9976, respectively. The detection limit and enrichment factor for morphine and codeine are 1.8 ng L-1, 1000 and 2.1 ng L-1, 1000, respectively. The presented technique was employed for the monitoring of morphine and codeine in numerous blood and urine samples with relative recoveries between 97.0 and 102.5%, and relative standard deviations of 1.02-5.10% for the spiked samples. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:2 / 9
页数:8
相关论文
共 32 条
[1]   Biosorption of Zn2+, Ni2+ and Co2+ from water samples onto Yarrowia lipolytica ISF7 using a response surface methodology, and analyzed by inductively coupled plasma optical emission spectrometry (ICP-OES) [J].
Asfaram, Arash ;
Ghaedi, Mehrorang ;
Ghezelbash, Gholam Reza .
RSC ADVANCES, 2016, 6 (28) :23599-23610
[2]   Characterization and temperature-dependent conductivity of polyaniline nanocomposites encapsulating gold nanoparticles on the surface of carboxymethyl cellulose [J].
Basavaraja, C. ;
Kim, Jin Kyung ;
Huh, Do Sung .
MATERIALS SCIENCE AND ENGINEERING B-ADVANCED FUNCTIONAL SOLID-STATE MATERIALS, 2013, 178 (02) :167-173
[3]   Silane modified magnetic nanoparticles as a novel adsorbent for determination of morphine at trace levels in human hair samples by high-performance liquid chromatography with diode array detection [J].
Boojaria, Ali ;
Masrournia, Mahboubeh ;
Ghorbani, Hamideh ;
Ebrahimitalab, Abdolhossein ;
Miandarhoie, Mina .
FORENSIC SCIENCE MEDICINE AND PATHOLOGY, 2015, 11 (04) :497-503
[4]   Simultaneous determination of morphine, codeine and 6-acetyl morphine in human urine and blood samples using direct aqueous derivatisation: Validation and application to real cases [J].
Chericoni, S. ;
Stefanelli, F. ;
Iannella, V. ;
Giusiani, M. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 949 :127-132
[5]   A Dilute-and-Shoot LC-MS Method for Quantitating Opioids in Oral Fluid [J].
Enders, Jeffrey R. ;
McIntire, Gregory L. .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (08) :662-667
[6]   A new electrochemical sensor based on Fe3O4 functionalized graphene oxide-gold nanoparticle composite film for simultaneous determination of catechol and hydroquinone [J].
Erogul, Seyma ;
Bas, Salih Zeki ;
Ozmen, Mustafa ;
Yildiz, Salih .
ELECTROCHIMICA ACTA, 2015, 186 :302-313
[7]  
Fekete S., 2014, CURR CHROMATOGR, V1, P15
[8]   Development of a Powdered Activated Carbon in Bar Adsorptive Micro-Extraction for the Analysis of Morphine and Codeine in Human Urine [J].
Goncalves, A. F. P. ;
Neng, N. R. ;
Mestre, A. S. ;
Carvalho, A. P. ;
Nogueira, J. M. F. .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2012, 50 (07) :574-581
[9]  
Grabenauer M., 2018, J ANAL TOXICOL, V42, P1, DOI [10.1093/jatibky021, DOI 10.1093/JATIBKY021]
[10]   Rapid detection of illicit drugs in neat saliva using desorption/ionization on porous silicon [J].
Guinan, Taryn ;
Ronci, Maurizio ;
Kobus, Hilton ;
Voelcker, Nicolas H. .
TALANTA, 2012, 99 :791-798