Silicone oil adhesion to intraocular lenses: An experimental study comparing various biomaterials

被引:64
作者
Apple, DJ
Isaacs, RT
Kent, DG
Martinez, LM
Kim, S
Thomas, SG
Basti, S
Barker, D
Peng, Q
机构
[1] Department of Ophthalmology, Medical University of South Carolina, Charleston, SC 29425-2236
关键词
D O I
10.1016/S0886-3350(97)80210-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To perform an in vitro experimental study comparing the degree of adherence of silicone oil to various rigid and foldable intraocular lens (IOL) designs and to the human lens capsule. Setting: Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. Methods: Seven IOL styles comprising various biomaterials were studied: fluorine-treated (Fluorlens(TM)), heparin-surface-modified (HSM(TM)), hydrogel, Memory-Lens(TM), poly(methyl methacrylate) (PMMA), soft acrylic, and silicone lenses; the human crystalline lens was also studied. Each lens was immersed in silicone oil for 12 hours, then photographed, studied by scanning electron microscopy (except the crystalline lens), and subjected to computer-generated image analysis to determine the silicone oil coverage. Results: Silicone oil coverage of dry silicone lenses was 100% and of lenses immersed in normal saline, 82.5%. The least coverage was on the heparin-surface-modified lens (mean score 9.4%). Coverage of the other four lenses ranged from approximately 15.1% to 33.7%. Mean coverage of the human lens capsule was 10.9%. Conclusion: Although a silicone IOL shows maximal adherence to silicone oil, other lens biomaterials are not immune to this complication. Silicone oil coverage was related to the dispersive energy component of the surface charge of the IOL biomaterial. Low dispersive energy materials had less silicone oil coverage, while those with higher dispersive energy had more oil coverage.
引用
收藏
页码:536 / 544
页数:9
相关论文
共 19 条
[1]  
Andrade J D, 1973, Med Instrum, V7, P110
[2]   Irreversible silicone oil adhesion to silicone intraocular lenses - A clinicopathologic analysis [J].
Apple, DJ ;
Federman, JL ;
Krolicki, TJ ;
Sims, JCR ;
Kent, DG ;
Hamburger, HA ;
Smiddy, WE ;
Cox, MS ;
Hassan, TS ;
Compton, SM ;
Thomas, SG .
OPHTHALMOLOGY, 1996, 103 (10) :1555-1561
[3]  
Baier R.E., 1970, ADHESION BIOL SYSTEM, P15
[4]   THE ADHERENCE OF SILICONE OIL TO STANDARD AND HEPARIN-COATED PMMA INTRAOCULAR LENSES [J].
BATTERBURY, M ;
WONG, D ;
WILLIAMS, R ;
BATES, R .
EYE, 1994, 8 :547-549
[5]  
CUNANAN CM, 1991, J CATARACT REFR SURG, V17, P767
[6]   COMPLICATIONS ASSOCIATED WITH THE USE OF SILICONE OIL IN 150 EYES AFTER RETINA-VITREOUS SURGERY [J].
FEDERMAN, JL ;
SCHUBERT, HD .
OPHTHALMOLOGY, 1988, 95 (07) :870-876
[7]   SILICONE OIL INSERTION - A REVIEW OF 127 CONSECUTIVE CASES [J].
FISK, MJ ;
CAIRNS, JD .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF OPHTHALMOLOGY, 1995, 23 (01) :25-32
[8]  
FRANKS W A, 1991, Eye (London), V5, P333
[9]   Condensation on polymethylmethacrylate, acrylic polymer, and silicone intraocular lenses after fluid-air exchange in rabbits [J].
Hainsworth, DP ;
Chen, SN ;
Cox, TA ;
Jaffe, GJ .
OPHTHALMOLOGY, 1996, 103 (09) :1410-1418
[10]   EFFECTS OF SILICONE OIL REMOVAL - SILICONE STUDY REPORT-6 [J].
HUTTON, WL ;
AZEN, SP ;
BLUMENKRANZ, MS ;
LAI, MY ;
MCCUEN, BW ;
HAN, DP ;
FLYNN, HW ;
RAMSAY, RC ;
RYAN, SJ .
ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (06) :778-785