Separation of caffeine and theophylline in poly(dimethylsiloxane) microchannel electrophoresis with electrochemical detection

被引:49
|
作者
Zhang, QL [1 ]
Lian, HZ [1 ]
Wang, WH [1 ]
Chen, HY [1 ]
机构
[1] Nanjing Univ, Dept Chem, Key Lab Analyt Chem Life Sci, Nanjing 210093, Peoples R China
基金
中国国家自然科学基金;
关键词
PDMS microchannel electrophoresis; electrochemical detection; caffeine; theophylline;
D O I
10.1016/j.chroma.2005.08.055
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method for the rapid separation and sensitive determination of caffeine and theophylline was presented in poly(ditmethylsiloxane) (PDMS) microchannel electrophoresis integrated with electrochemical detection. By using methanol as an additive, the peak shape and resolution were essentially improved. The analytes were well separated within only 40s in the running buffer of 5.0 mM borate solution (pH 9.2) containing 10% (v/v) methanol. The linear ranges were from 6 mu M to 0.6 mM and the detection limits were 4 mu M for caffeine and theophylline, respectively. The proposed method has been successfully applied to determine caffeine and theophylline in rat serum and urine, (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:172 / 176
页数:5
相关论文
共 50 条
  • [1] Separation of three water-soluble vitamins by poly(dimethylsiloxane) microchannel electrophoresis with electrochemical detection
    Li, Xiang-Yun
    Zhang, Qian-Li
    Lian, Hong-Zhen
    Xu, Jing-Juan
    Chen, Hong-Yuan
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (14) : 2320 - 2325
  • [3] Covalent modified hydrophilic polymer brushes onto poly(dimethylsiloxane) microchannel surface for electrophoresis separation of amino acids
    Wang, Ai-Jun
    Feng, Jiu-Ju
    Fan, Jing
    JOURNAL OF CHROMATOGRAPHY A, 2008, 1192 (01) : 173 - 179
  • [4] Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips
    Martin, RS
    Gawron, AJ
    Lunte, SM
    Henry, CS
    ANALYTICAL CHEMISTRY, 2000, 72 (14) : 3196 - 3202
  • [5] Determination of morphine and codeine in urine using poly(dimethylsiloxane) microchip electrophoresis with electrochemical detection
    Zhang, Qian-Li
    Xu, Jing-Juan
    Li, Xiang-Yun
    Lian, Hong-Zhen
    Chen, Hong-Yuan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (01) : 237 - 242
  • [6] Enhanced electrophoresis separation of non-electroactive amino acids on poly(dimethylsiloxane) microchip coupled with direct electrochemical detection on a copper electrode
    Liang, Ruping
    Wang, Li
    Meng, Xiangying
    Wang, Jingwu
    Qiu, Jianding
    MICROFLUIDICS AND NANOFLUIDICS, 2011, 11 (02) : 227 - 233
  • [7] Poly(dimethylsiloxane) microchip capillary electrophoresis with electrochemical detection for rapid measurement of acetaminophen and its hydrolysate
    He, FY
    Liu, AL
    Xia, XH
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 379 (7-8) : 1062 - 1067
  • [8] Poly(dimethylsiloxane) microchip capillary electrophoresis with electrochemical detection for rapid measurement of acetaminophen and its hydrolysate
    F. Y. He
    A. L. Liu
    X. H. Xia
    Analytical and Bioanalytical Chemistry, 2004, 379 : 1062 - 1067
  • [9] Enhanced electrophoresis separation of non-electroactive amino acids on poly(dimethylsiloxane) microchip coupled with direct electrochemical detection on a copper electrode
    Ruping Liang
    Li Wang
    Xiangying Meng
    Jingwu Wang
    Jianding Qiu
    Microfluidics and Nanofluidics, 2011, 11 : 227 - 233
  • [10] On-chip electric field driven electrochemical detection using a poly(dimethylsiloxane) microchannel with gold microband electrodes
    Ordeig, Olga
    Godino, Neus
    del Campo, Javier
    Munoz, Francesc Xavier
    Nikolajeff, Fredrik
    Nyholm, Leif
    ANALYTICAL CHEMISTRY, 2008, 80 (10) : 3622 - 3632