Microfluidic chip-based valveless flow injection analysis system with gravity-driven flows

被引:11
作者
Huang, Yang-Zhen [1 ]
Du, Wen-Bin [1 ]
Pan, Jian-Zhang [1 ]
Fang, Qun [1 ]
机构
[1] Zhejiang Univ, Dept Chem, Inst Microanalyt Syst, Hangzhou 310058, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
D O I
10.1039/b807494a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, a microfluidic chip-based valveless flow injection analysis (FIA) system with gravity-driven flows and liquid-core waveguide (LCW) spectrometric detection was developed. Automated sample injection in the 0.3-6.4 nL range under gated injection mode was achieved by controlling the vertical position of the waste reservoir fixed on a moving platform and the residence time of the reservoir in each position, without the requirement of microvalves or electrokinetic manipulation. An integrated LCW spectrometric detection system was built on the chip by coupling a 20 mm-long Teflon AF 2400 capillary with the microchannel to function as a LCW flow cell, using a green LED as light source and a photodiode as detector. The performance of the system was demonstrated in the determination of [NO2](2-) based on the Saltzman reaction. Linear absorbance response was obtained in the range of 0.1-20 mg L-1 (R-2 = 0.9910), and a good reproducibility of 0.34% RSD (n = 17) was achieved.
引用
收藏
页码:1237 / 1241
页数:5
相关论文
共 50 条
[21]   Chip-based amperometric enzyme sensor system for monitoring of bioprocesses by flow-injection analysis [J].
Baecker, M. ;
Rakowski, D. ;
Poghossian, A. ;
Biselli, M. ;
Wagner, P. ;
Schoening, M. J. .
JOURNAL OF BIOTECHNOLOGY, 2013, 163 (04) :371-376
[22]   Accurate prediction of drug-induced heterogeneous response of red cell in vivo using a gravity-driven flow cytometry based on a microfluidic chip [J].
Chen, Yue ;
Zhan, Qiong ;
Zhang, Jian ;
Wang, Wei ;
Khoo, Bee Luan ;
Liu, Zhen ;
Wei, Siqi ;
Niu, Junxin ;
Xu, Jun ;
Yu, Chia-Chen ;
Hu, Xiumei ;
Liu, Yanhui ;
Han, Jongyoon ;
Liu, Shuwen ;
Liu, Lihong .
ANALYTICA CHIMICA ACTA, 2022, 1221
[23]   Microfluidic chip-based analytical system for rapid screening of photocatalysts [J].
Zhang, Hao ;
Wang, Jing-Jing ;
Fan, Jie ;
Fang, Qun .
TALANTA, 2013, 116 :946-950
[24]   Gravity-driven preprogrammed microfluidic recirculation system for parallel biosensing of cell behaviors [J].
Boonyaphon, Korakot ;
Li, Zhenglin ;
Kim, Sung-Jin .
Analytica Chimica Acta, 2022, 1233
[25]   Improved protein identification using a microfluidic chip-based system [J].
Miller, C. ;
Vollmer, M. .
MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) :S308-S308
[26]   Numerical study of gravity-driven dense granular flows on flow behavior characterization [J].
Li, Yu ;
Gui, Nan ;
Yang, Xingtuan ;
Tu, Jiyuan ;
Jiang, Shengyao .
POWDER TECHNOLOGY, 2016, 297 :144-152
[27]   Gravity-driven preprogrammed microfluidic recirculation system for parallel biosensing of cell behaviors [J].
Boonyaphon, Korakot ;
Li, Zhenglin ;
Kim, Sung-Jin .
ANALYTICA CHIMICA ACTA, 2022, 1233
[28]   Gravity-driven Microfluidic Chip Based on RPA-CRISPR/Cas12a for the Rapid Detection of Mycobacterium tuberculosis [J].
Gao, Chang ;
Zhuang, Tian-Chi ;
Li, Ning ;
Liu, Yun ;
Gu, Peng-Fei ;
Zhao, Xin-Yi ;
Ji, Ming-Hui .
Biotechnology Bulletin, 2025, 41 (05) :62-69
[29]   A gravity driven micro flow injection wetting film extraction system on a polycarbonate chip [J].
Cai, ZX ;
Chen, HW ;
Chen, B ;
Huang, CB .
TALANTA, 2006, 68 (03) :895-901
[30]   Stability analysis of traveling wave solution for gravity-driven flow [J].
Egorov, AG ;
Dautov, RZ ;
Nieber, JL ;
Sheshukov, AY .
COMPUTATIONAL METHODS IN WATER RESOURCES, VOLS 1 AND 2, PROCEEDINGS, 2002, 47 :121-128