Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: Normal limits and correlation with invasive coronary angiography

被引:50
作者
Nakazato, Ryo [1 ,2 ,3 ]
Berman, Daniel S. [1 ,2 ,3 ,6 ]
Dey, Damini [4 ,5 ,6 ]
Le Meunier, Ludovic [7 ]
Hayes, Sean W. [1 ,2 ,3 ,6 ]
Fermin, Jimmy S. [1 ,2 ,3 ]
Cheng, Victor Y. [1 ,2 ,3 ]
Thomson, Louise E. J. [1 ,2 ,3 ,6 ]
Friedman, John D. [1 ,2 ,3 ,6 ]
Germano, Guido [1 ,2 ,3 ,6 ]
Slomka, Piotr J. [1 ,2 ,3 ,6 ]
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Med, Los Angeles, CA 90048 USA
[3] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
[4] Cedars Sinai Med Ctr, Dept Biomed Sci, Los Angeles, CA 90048 USA
[5] Cedars Sinai Med Ctr, Biomed Imaging Res Inst, Los Angeles, CA 90048 USA
[6] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[7] Siemens Med Solut, PET Div, Knoxville, TN USA
关键词
PET/CT; myocardial perfusion imaging; quantification; 3D; coronary artery disease; POSITRON-EMISSION-TOMOGRAPHY; EJECTION FRACTION; ARTERY-DISEASE; DIAGNOSTIC-ACCURACY; PROGNOSTIC VALUE; SPECT; QUANTIFICATION; STRESS; VALIDATION; STATEMENT;
D O I
10.1007/s12350-011-9496-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We aimed to characterize normal limits and to determine the diagnostic accuracy for an automated quantification of 3D 82-Rubidium (Rb-82) PET/CT myocardial perfusion imaging (MPI). Methods. We studied 125 consecutive patients undergoing Rb-82 PET/CT MPI, including patients with suspected coronary artery disease (CAD) and invasive coronary angiography, and 42 patients with a low likelihood (LLk) of CAD. Normal limits for perfusion and function were derived from LLk patients. QPET software was used to quantify perfusion abnormality at rest and stress expressed as total perfusion deficit (TPD). Results. Relative perfusion databases did not differ in any of the 17 segments between males and females. The areas under the receiver operating characteristic curve for detection of CAD were 0.86 for identification of >= 50% and >= 70% stenosis. The sensitivity/specificity was 86%/86% for detecting >= 50% stenosis and 93%/77% for >= 70% stenosis, respectively. In regard to normal limits, mean rest and stress left ventricular ejection fraction (LVEF) were 67% +/- 10% and 75% +/- 9%, respectively. Mean transient ischemic dilation ratio was 1.06 +/- 0.14 and mean increase in LVEF with stress was 7.4% +/- 6.1% (95th percentile of 0%). Conclusion. Normal limits have been established for 3D Rb-82 PET/CT analysis with QPET software. Fully automated quantification of myocardial perfusion PET data shows high diagnostic accuracy for detecting obstructive CAD. (J Nucl Cardiol 2012;19:265-76.)
引用
收藏
页码:265 / 276
页数:12
相关论文
共 50 条
  • [41] Automated Motion Correction for Myocardial Blood Flow Measurements and Diagnostic Performance of 82Rb PET Myocardial Perfusion Imaging
    Kuronuma, Keiichiro
    Wei, Chih-Chun
    Singh, Ananya
    Lemley, Mark
    Hayes, Sean W.
    Otaki, Yuka
    Hyun, Mark C.
    Van Kriekinge, Serge D.
    Kavanagh, Paul
    Huang, Cathleen
    Han, Donghee
    Dey, Damini
    Berman, Daniel S.
    Slomka, Piotr J.
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65 (01) : 139 - 146
  • [42] Prognosis of a Normal Positron Emission Tomography 82Rb Myocardial Perfusion Imaging Study in Women with No History of Coronary Disease
    Van Tosh, Andrew
    Supino, Phyllis G.
    Nichols, Kenneth J.
    Garza, Dahlia
    Horowitz, Steven F.
    Reichek, Nathaniel
    CARDIOLOGY, 2010, 117 (04) : 301 - 306
  • [43] Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging
    Burkhard, Nina
    Herzog, Bernhard A.
    Husmann, Lars
    Pazhenkottil, Aju P.
    Burger, Irene A.
    Buechel, Ronny R.
    Valenta, Ines
    Wyss, Christophe A.
    Kaufmann, Philipp A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (03) : 517 - 521
  • [44] Multisoftware Reproducibility Study of Stress and Rest Myocardial Blood Flow Assessed with 3D Dynamic PET/CT and a 1-Tissue-Compartment Model of 82Rb Kinetics
    deKemp, Robert A.
    Declerck, Jerome
    Klein, Ran
    Pan, Xiao-Bo
    Nakazato, Ryo
    Tonge, Christine
    Arumugam, Parthiban
    Berman, Daniel S.
    Germano, Guido
    Beanlands, Rob S.
    Slomka, Piotr J.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (04) : 571 - 577
  • [45] Comparison of occupational radiation exposure from myocardial perfusion imaging with Rb-82 PET and Tc-99m SPECT
    Tout, Deborah
    Davidson, Gillian
    Hurley, Caroline
    Bartley, Michelle
    Arumugam, Parthiban
    Bradley, Andy
    NUCLEAR MEDICINE COMMUNICATIONS, 2014, 35 (10) : 1032 - 1037
  • [46] Assessment of left ventricular function at rest using rubidium-82 myocardial perfusion PET: comparison of four software algorithms with simultaneous 64-slice coronary CT angiography
    Menezes, Leon J.
    Groves, Ashley M.
    Prvulovich, Elizabeth
    Dickson, John C.
    Endozo, Raymond
    Shastry, Manu H.
    Kayani, Irfan A.
    Papathanasiou, Nikolaos D.
    Bomanji, Jamshed B.
    Ell, Peter J.
    NUCLEAR MEDICINE COMMUNICATIONS, 2009, 30 (12) : 918 - 925
  • [47] Myocardial Flow Reserve Measurement During CZT-SPECT Perfusion Imaging for Coronary Artery Disease Screening: Correlation With Clinical Findings and Invasive Coronary Angiography-The CFR-OR Study
    Bailly, Matthieu
    Thibault, Frederique
    Courtehoux, Maxime
    Metrard, Gilles
    Angoulvant, Denis
    Ribeiro, Maria Joao
    FRONTIERS IN MEDICINE, 2021, 8
  • [48] Low radiation dose imaging of myocardial perfusion and coronary angiography with a hybrid PET/CT scanner
    Kajander, S.
    Ukkonen, H.
    Sipila, H.
    Teras, M.
    Knuuti, J.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2009, 29 (01) : 81 - 88
  • [49] 3D Fusion Between SPECT Myocardial Perfusion Imaging and Invasive Coronary Angiography to Guide Revascularization in Patients With Stable Coronary Artery Disease
    Xu, Zhihui
    Malhotra, Saurabh
    Zhao, Chen
    Li, Chunjian
    Ye, Zekang
    Hua, Rui
    Wang, Cheng
    Zhou, Weihua
    CIRCULATION, 2023, 148
  • [50] 3D versus 2D dynamic 82Rb myocardial blood flow imaging in a canine model of stunned and infarcted myocardium
    Lekx, Katie S.
    deKemp, Robert A.
    Beanlands, Rob S. B.
    Wisenberg, Gerald
    Wells, Glenn
    Stodilka, Robert Z.
    Lortie, Mireille
    Klein, Ran
    Zabel, Pamela
    Kovacs, Michael S.
    Sykes, Jane
    Prato, Frank S.
    NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (01) : 75 - 81