Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: Normal limits and correlation with invasive coronary angiography

被引:50
作者
Nakazato, Ryo [1 ,2 ,3 ]
Berman, Daniel S. [1 ,2 ,3 ,6 ]
Dey, Damini [4 ,5 ,6 ]
Le Meunier, Ludovic [7 ]
Hayes, Sean W. [1 ,2 ,3 ,6 ]
Fermin, Jimmy S. [1 ,2 ,3 ]
Cheng, Victor Y. [1 ,2 ,3 ]
Thomson, Louise E. J. [1 ,2 ,3 ,6 ]
Friedman, John D. [1 ,2 ,3 ,6 ]
Germano, Guido [1 ,2 ,3 ,6 ]
Slomka, Piotr J. [1 ,2 ,3 ,6 ]
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Med, Los Angeles, CA 90048 USA
[3] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
[4] Cedars Sinai Med Ctr, Dept Biomed Sci, Los Angeles, CA 90048 USA
[5] Cedars Sinai Med Ctr, Biomed Imaging Res Inst, Los Angeles, CA 90048 USA
[6] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[7] Siemens Med Solut, PET Div, Knoxville, TN USA
关键词
PET/CT; myocardial perfusion imaging; quantification; 3D; coronary artery disease; POSITRON-EMISSION-TOMOGRAPHY; EJECTION FRACTION; ARTERY-DISEASE; DIAGNOSTIC-ACCURACY; PROGNOSTIC VALUE; SPECT; QUANTIFICATION; STRESS; VALIDATION; STATEMENT;
D O I
10.1007/s12350-011-9496-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We aimed to characterize normal limits and to determine the diagnostic accuracy for an automated quantification of 3D 82-Rubidium (Rb-82) PET/CT myocardial perfusion imaging (MPI). Methods. We studied 125 consecutive patients undergoing Rb-82 PET/CT MPI, including patients with suspected coronary artery disease (CAD) and invasive coronary angiography, and 42 patients with a low likelihood (LLk) of CAD. Normal limits for perfusion and function were derived from LLk patients. QPET software was used to quantify perfusion abnormality at rest and stress expressed as total perfusion deficit (TPD). Results. Relative perfusion databases did not differ in any of the 17 segments between males and females. The areas under the receiver operating characteristic curve for detection of CAD were 0.86 for identification of >= 50% and >= 70% stenosis. The sensitivity/specificity was 86%/86% for detecting >= 50% stenosis and 93%/77% for >= 70% stenosis, respectively. In regard to normal limits, mean rest and stress left ventricular ejection fraction (LVEF) were 67% +/- 10% and 75% +/- 9%, respectively. Mean transient ischemic dilation ratio was 1.06 +/- 0.14 and mean increase in LVEF with stress was 7.4% +/- 6.1% (95th percentile of 0%). Conclusion. Normal limits have been established for 3D Rb-82 PET/CT analysis with QPET software. Fully automated quantification of myocardial perfusion PET data shows high diagnostic accuracy for detecting obstructive CAD. (J Nucl Cardiol 2012;19:265-76.)
引用
收藏
页码:265 / 276
页数:12
相关论文
共 50 条
  • [31] The prognostic value of automated coronary calcium derived by a deep learning approach on non-ECG gated CT images from 82Rb-PET/CT myocardial perfusion imaging
    Dekker, Mirthe
    Waissi, Farahnaz
    Bank, Ingrid E. M.
    Isgum, Ivana
    Scholtens, Asbjorn M.
    Velthuis, Birgitta K.
    Pasterkamp, Gerard
    de Winter, Robbert J.
    Mosterd, Arend
    Timmers, Leo
    de Kleijn, Dominique P., V
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2021, 329 : 9 - 15
  • [32] Effects of two patient-specific dosing protocols on measurement of myocardial blood flow with 3D 82Rb cardiac PET
    Arida-Moody, Liliana
    Moody, Jonathan B.
    Renaud, Jennifer M.
    Poitrasson-Riviere, Alexis
    Hagio, Tomoe
    Smith, Anne M.
    Ficaro, Edward P.
    Murthy, Venkatesh L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (12) : 3835 - 3846
  • [33] Static CT myocardial perfusion imaging: image quality, artifacts including distribution and diagnostic performance compared to 82Rb PET
    Inacio, Joao R.
    Srinivasan, Sriraag Balaji
    Ruddy, Terrence D.
    DeKemp, Robert A.
    Rybicki, Frank
    Beanlands, Rob S.
    Chow, Benjamin J. W.
    Dwivedi, Girish
    EUROPEAN JOURNAL OF HYBRID IMAGING, 2022, 6 (01):
  • [34] Predictors of severe stenosis at invasive coronary angiography in patients with normal myocardial perfusion imaging
    S. Yokota
    J. P. Ottervanger
    M. Mouden
    M. J. de Boer
    P. L. Jager
    J. R. Timmer
    Netherlands Heart Journal, 2018, 26 : 192 - 202
  • [35] Quantitative coronary arterial stenosis assessment by multidetector CT and invasive coronary angiography for identifying patients with myocardial perfusion abnormalities
    Godoy, G. K.
    Vavere, A.
    Miller, J. M.
    Chahal, H.
    Niinuma, H.
    Lemos, P.
    Hoe, J.
    Paul, N.
    Clouse, M. E.
    Ramos, C. D.
    Lima, J. A.
    Arbab-Zadeh, A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (05) : 922 - 930
  • [36] SPECT/PET myocardial perfusion imaging versus coronary CT angiography in patients with known or suspected CAD
    Berman, D. S.
    Shaw, L. J.
    Min, J. K.
    Hachamovitch, R.
    Abidov, A.
    Germano, G.
    Hayes, S. W.
    Friedman, J. D.
    Thomson, L. E. J.
    Kang, X.
    Slomka, P.
    Rozanski, A.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 54 (02) : 177 - 200
  • [37] Quantitative Upright/Supine High-Speed Myocardial Perfusion Imaging: Correlation with Invasive Coronary Angiography
    Nakazato, Ryo
    Tamarappoo, Balaji K.
    Kang, Xingping
    Hayes, Sean W.
    Thomson, Louise E.
    Friedman, John D.
    Berman, Daniel S.
    Slomka, Piotr J.
    CIRCULATION, 2010, 122 (21)
  • [38] 82Rb PET myocardial perfusion imaging is superior to 99mTc-labelled agent SPECT in patients with known or suspected coronary artery disease
    Flotats, Albert
    Bravo, Paco E.
    Fukushima, Kenji
    Chaudhry, Muhammad A.
    Merrill, Jennifer
    Bengel, Frank M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (08) : 1233 - 1239
  • [39] Quantitative myocardial perfusion PET combined with coronary anatomy derived from CT angiography: Validation of a new fusion and visualisation software
    Fricke, Harald
    Elsner, Andreas
    Weise, Reiner
    Bolte, Matthias
    van den Hoff, Joerg
    Burchert, Wolfgang
    Domik, Gitta
    Fricke, Eva
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2009, 19 (03): : 182 - 188
  • [40] Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software
    Ebersberger, Ullrich
    Marcus, Roy P.
    Schoepf, U. Joseph
    Lo, Gladys G.
    Wang, Yining
    Blanke, Philipp
    Geyer, Lucas L.
    Gray, J. Cranston, III
    McQuiston, Andrew D.
    Cho, Young Jun
    Scheuering, Michael
    Canstein, Christian
    Nikolaou, Konstantin
    Hoffmann, Ellen
    Bamberg, Fabian
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 191 - 199