Automated quantitative Rb-82 3D PET/CT myocardial perfusion imaging: Normal limits and correlation with invasive coronary angiography

被引:55
作者
Nakazato, Ryo [1 ,2 ,3 ]
Berman, Daniel S. [1 ,2 ,3 ,6 ]
Dey, Damini [4 ,5 ,6 ]
Le Meunier, Ludovic [7 ]
Hayes, Sean W. [1 ,2 ,3 ,6 ]
Fermin, Jimmy S. [1 ,2 ,3 ]
Cheng, Victor Y. [1 ,2 ,3 ]
Thomson, Louise E. J. [1 ,2 ,3 ,6 ]
Friedman, John D. [1 ,2 ,3 ,6 ]
Germano, Guido [1 ,2 ,3 ,6 ]
Slomka, Piotr J. [1 ,2 ,3 ,6 ]
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, Los Angeles, CA 90048 USA
[2] Cedars Sinai Med Ctr, Dept Med, Los Angeles, CA 90048 USA
[3] Cedars Sinai Med Ctr, Cedars Sinai Heart Inst, Los Angeles, CA 90048 USA
[4] Cedars Sinai Med Ctr, Dept Biomed Sci, Los Angeles, CA 90048 USA
[5] Cedars Sinai Med Ctr, Biomed Imaging Res Inst, Los Angeles, CA 90048 USA
[6] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[7] Siemens Med Solut, PET Div, Knoxville, TN USA
关键词
PET/CT; myocardial perfusion imaging; quantification; 3D; coronary artery disease; POSITRON-EMISSION-TOMOGRAPHY; EJECTION FRACTION; ARTERY-DISEASE; DIAGNOSTIC-ACCURACY; PROGNOSTIC VALUE; SPECT; QUANTIFICATION; STRESS; VALIDATION; STATEMENT;
D O I
10.1007/s12350-011-9496-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. We aimed to characterize normal limits and to determine the diagnostic accuracy for an automated quantification of 3D 82-Rubidium (Rb-82) PET/CT myocardial perfusion imaging (MPI). Methods. We studied 125 consecutive patients undergoing Rb-82 PET/CT MPI, including patients with suspected coronary artery disease (CAD) and invasive coronary angiography, and 42 patients with a low likelihood (LLk) of CAD. Normal limits for perfusion and function were derived from LLk patients. QPET software was used to quantify perfusion abnormality at rest and stress expressed as total perfusion deficit (TPD). Results. Relative perfusion databases did not differ in any of the 17 segments between males and females. The areas under the receiver operating characteristic curve for detection of CAD were 0.86 for identification of >= 50% and >= 70% stenosis. The sensitivity/specificity was 86%/86% for detecting >= 50% stenosis and 93%/77% for >= 70% stenosis, respectively. In regard to normal limits, mean rest and stress left ventricular ejection fraction (LVEF) were 67% +/- 10% and 75% +/- 9%, respectively. Mean transient ischemic dilation ratio was 1.06 +/- 0.14 and mean increase in LVEF with stress was 7.4% +/- 6.1% (95th percentile of 0%). Conclusion. Normal limits have been established for 3D Rb-82 PET/CT analysis with QPET software. Fully automated quantification of myocardial perfusion PET data shows high diagnostic accuracy for detecting obstructive CAD. (J Nucl Cardiol 2012;19:265-76.)
引用
收藏
页码:265 / 276
页数:12
相关论文
共 38 条
[1]   Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT [J].
Bateman, TM ;
Heller, GV ;
McGhie, AI ;
Friedman, JD ;
Case, JA ;
Bryngelson, JR ;
Hertenstein, GK ;
Moutray, KL ;
Reid, K ;
Cullom, SJ .
JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (01) :24-33
[2]   CCS/CAR/CANM/CNCS/CanSCMR joint position statement on advanced noninvasive cardiac imaging using positron emission tomography, magnetic resonance imaging and multidetector computed tomographic angiography in the diagnosis and evaluation of ischemic heart disease - executive summary [J].
Beanlands, R. S. B. ;
Chow, B. J. W. ;
Dick, A. ;
Friedrich, M. G. ;
Gulenchyn, K. Y. ;
Kiess, M. ;
Leong-Poi, H. ;
Miller, R. M. ;
Nichol, G. ;
Freeman, M. ;
Bogaty, P. ;
Honos, G. ;
Hudon, G. ;
Wisenberg, G. ;
Van Berkom, J. ;
Williams, K. ;
Yoshinaga, K. ;
Graham, J. .
CANADIAN JOURNAL OF CARDIOLOGY, 2007, 23 (02) :107-119
[3]   Quantitative assessment of myocardial perfusion abnormality on SPECT myocardial perfusion imaging is more reproducible than expert visual analysis [J].
Berman, Daniel S. ;
Kang, Xingping ;
Gransar, Heidi ;
Gerlach, James ;
Friedman, John D. ;
Hayes, Sean W. ;
Thomson, Louise E. J. ;
Hachamovitch, Rory ;
Shaw, Leslee J. ;
Slomka, Piotr J. ;
De Yang, Ling ;
Germano, Guido .
JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (01) :45-53
[4]   Adenosine myocardial perfusion single-photon emission computed tomography in women compared with men - Impact of diabetes mellitus on incremental prognostic value and effect on patient management [J].
Berman, DS ;
Kang, XP ;
Hayes, SW ;
Friedman, JD ;
Cohen, I ;
Abidov, A ;
Shaw, LJ ;
Amanullah, AM ;
Germano, G ;
Hachamovitch, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (07) :1125-1133
[5]   Reference Ranges for LVEF and LV Volumes from Electrocardiographically Gated 82Rb Cardiac PET/CT Using Commercially Available Software [J].
Bravo, Paco E. ;
Chien, David ;
Javadi, Mehrbod ;
Merrill, Jennifer ;
Bengel, Frank M. .
JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (06) :898-905
[6]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[7]   SAFETY PROFILE OF ADENOSINE STRESS PERFUSION IMAGING - RESULTS FROM THE ADENOSCAN-MULTICENTER-TRIAL-REGISTRY [J].
CERQUEIRA, MD ;
VERANI, MS ;
SCHWAIGER, M ;
HEO, J ;
ISKANDRIAN, AS ;
ALAZRAKI, NP ;
BEAN, LC ;
BELARDINELLI, L ;
BELL, M ;
BERMAN, DS ;
BOTVINICK, EH ;
CHEIRIF, J ;
HANSEN, CL ;
HELLER, GV ;
JOHNSTON, DL ;
LEPPO, JA ;
MADDAHI, J ;
PARKER, LS ;
MOHIUDDIN, S ;
RAICHLEN, JS ;
REIS, GJ ;
SCHELBERT, HR ;
SEALS, AA ;
STOLZENBERG, J ;
WILLIAMS, KA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) :384-389
[8]  
Cullom S, 2007, J NUCL MED, V48
[9]   New technology for noninvasive evaluation of coronary artery disease [J].
Di Carli, Marcelo F. ;
Hachamovitch, Rory .
CIRCULATION, 2007, 115 (11) :1464-1480
[10]   ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) :1350-1358