摘要
Data obtained from functional magnetic resonance imaging are often limited by a low signal-to-noise ratio, The timecourse data obtained from activated regions contain both system noise and physiological noise, primarily linked to the heart and respiratory rates, that are superimposed on task induced signals, Time averaging of a practical number of data sets-is not very effective in improving the signal-to-noise ratio because neither system nor physiological noise is truly random, In this paper, a method is presented for filtering unwanted physiological fluctuations, including aliased signals that are formed as a result of long repetition time (TR) values, A pulse oximeter was used to obtain cardiac and respiratory information during the scanning period, Finite impulse response band-reject digital filters were designed to remove the physiological fluctuations, For comparison, cross-correlation analyses were performed at the same level of statistical significance on both filtered and unfiltered data. We demonstrate that this method can improve the detection of weak signals without increasing the probability of false positives.
引用
收藏
页码:107 / 113
页数:7
相关论文
共 20 条
  • [1] TIME COURSE EPI OF HUMAN BRAIN-FUNCTION DURING TASK ACTIVATION
    BANDETTINI, PA
    WONG, EC
    HINKS, RS
    TIKOFSKY, RS
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 25 (02) : 390 - 397
  • [2] PROCESSING STRATEGIES FOR TIME-COURSE DATA SETS IN FUNCTIONAL MRI OF THE HUMAN BRAIN
    BANDETTINI, PA
    JESMANOWICZ, A
    WONG, EC
    HYDE, JS
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (02) : 161 - 173
  • [3] FUNCTIONAL MAPPING OF THE HUMAN VISUAL-CORTEX BY MAGNETIC-RESONANCE-IMAGING
    BELLIVEAU, JW
    KENNEDY, DN
    MCKINSTRY, RC
    BUCHBINDER, BR
    WEISSKOFF, RM
    COHEN, MS
    VEVEA, JM
    BRADY, TJ
    ROSEN, BR
    [J]. SCIENCE, 1991, 254 (5032) : 716 - 719
  • [4] BISWAL B, 1994, 2ND P SMR ANN M SAN, P653
  • [5] BISWAL B, 1993, 12TH P SMRM ANN M NE, P722
  • [6] SELF-REGULATION OF RESPIRATORY SINUS ARRHYTHMIA
    DELPASO, GAR
    GODOY, J
    VILA, J
    [J]. BIOFEEDBACK AND SELF-REGULATION, 1992, 17 (04): : 261 - 275
  • [7] FUNCTIONAL MAGNETIC-RESONANCE-IMAGING (FMRI) OF THE HUMAN BRAIN
    DEYOE, EA
    BANDETTINI, P
    NEITZ, J
    MILLER, D
    WINANS, P
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 1994, 54 (02) : 171 - 187
  • [8] THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING
    EDELSTEIN, WA
    GLOVER, GH
    HARDY, CJ
    REDINGTON, RW
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) : 604 - 618
  • [9] Guyton AC, 1976, Textbook of Medical Physiology, V5th
  • [10] Hamming RW, 1983, Digital Filters