Retinal imaging with adaptive optics

被引:18
作者
Le Gargasson, JF [1 ]
Glanc, M
Léna, P
机构
[1] Univ Paris 07, F-92195 Meudon, France
[2] Observ Paris, UMR CNRS 8632, F-92195 Meudon, France
[3] Univ Paris 07, Lab Biophys Vis, Unite INSERM 483, F-92195 Meudon, France
来源
COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE IV PHYSIQUE ASTROPHYSIQUE | 2001年 / 2卷 / 08期
关键词
vision; retinal imaging; adaptive optics;
D O I
10.1016/S1296-2147(01)01261-6
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Imaging the human retina in vivo is affected by the eye's natural aberrations, which limit the resolution of retinal images. Measuring these aberrations, including the high order ones, is possible using wavefront sensing techniques. A review of the rapid progress in this field is given. Once the aberrations are known, adaptive optics methods, developed for astronomical observing in the past 15 years, can be applied. in order either to improve retinal imaging or to give hyper-vision to the subject. Progress in this domain is reviewed, and some original results are reported with a new instrument. Future applications are discussed, including a possible three-dimensional, hi,gh-resolution method to image the human retina in vivo. (C) 2001 Academie des sciences/Editions scientifiques et medicales Elsevier SAS.
引用
收藏
页码:1131 / 1138
页数:8
相关论文
共 14 条
  • [1] Closed-loop adaptive optics in the human eye
    Fernández, EJ
    Iglesias, I
    Artal, P
    [J]. OPTICS LETTERS, 2001, 26 (10) : 746 - 748
  • [2] GLANC M, 2000, ADAPTIVE OPTICS IND
  • [3] Improvement in retinal image quality with dynamic correction of the eye's aberrations
    Hofer, H
    Chen, L
    Yoon, GY
    Singer, B
    Yamauchi, Y
    Williams, DR
    [J]. OPTICS EXPRESS, 2001, 8 (11): : 631 - 643
  • [4] Supernormal vision and high-resolution retinal imaging through adaptive optics
    Liang, JZ
    Williams, DR
    Miller, DT
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) : 2884 - 2892
  • [5] OBJECTIVE MEASUREMENT OF WAVE ABERRATIONS OF THE HUMAN EYE WITH THE USE OF A HARTMANN-SHACK WAVE-FRONT SENSOR
    LIANG, JZ
    GRIMM, B
    GOELZ, S
    BILLE, JF
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1994, 11 (07): : 1949 - 1957
  • [6] Aberrations and retinal image quality of the normal human eye
    Liang, JZ
    Williams, DR
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1997, 14 (11) : 2873 - 2883
  • [7] Images of cone photoreceptors in the living human eye
    Miller, DT
    Williams, DR
    Morris, GM
    Liang, JZ
    [J]. VISION RESEARCH, 1996, 36 (08) : 1067 - 1079
  • [8] Laser Ray Tracing versus Hartmann-Shack sensor for measuring optical aberrations in the human eye
    Moreno-Barriuso, E
    Navarro, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2000, 17 (06) : 974 - 985
  • [9] Analysis of the performance of the Hartmann-Shack sensor in the human eye
    Prieto, PM
    Vargas-Martín, F
    Goelz, S
    Artal, P
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2000, 17 (08): : 1388 - 1398
  • [10] Roddier F., 1999, ADAPTIVE OPTICS ASTR