Fluorescence Characterization of Clinically-Important Bacteria

被引:56
作者
Dartnell, Lewis R. [1 ,2 ]
Roberts, Tom A. [3 ]
Moore, Ginny [4 ]
Ward, John M. [5 ]
Muller, Jan-Peter [2 ,6 ]
机构
[1] UCL, UCL Inst Origins, London, England
[2] UCL, UCL Birkbeck, Ctr Planetary Sci, London, England
[3] UCL, Ctr Math & Phys Life Sci & Expt Biol CoMPLEX, London, England
[4] Univ Coll London Hosp NHS Fdn Trust, London, England
[5] UCL, Adv Ctr Biochem Engn, London, England
[6] Univ Coll London, Mullard Space Sci Lab, Surrey, England
来源
PLOS ONE | 2013年 / 8卷 / 09期
基金
英国科学技术设施理事会;
关键词
FLOW-CYTOMETRY; CLOSTRIDIUM-DIFFICILE; SPECTROSCOPY; IDENTIFICATION; CLASSIFICATION; WATER; MICROORGANISMS; OUTBREAK; SPECTRA; LIFE;
D O I
10.1371/journal.pone.0075270
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Healthcare-associated infections (HCAI/HAI) represent a substantial threat to patient health during hospitalization and incur billions of dollars additional cost for subsequent treatment. One promising method for the detection of bacterial contamination in a clinical setting before an HAI outbreak occurs is to exploit native fluorescence of cellular molecules for a hand-held, rapid-sweep surveillance instrument. Previous studies have shown fluorescence-based detection to be sensitive and effective for food-borne and environmental microorganisms, and even to be able to distinguish between cell types, but this powerful technique has not yet been deployed on the macroscale for the primary surveillance of contamination in healthcare facilities to prevent HAI. Here we report experimental data for the specification and design of such a fluorescence-based detection instrument. We have characterized the complete fluorescence response of eleven clinically-relevant bacteria by generating excitation-emission matrices (EEMs) over broad wavelength ranges. Furthermore, a number of surfaces and items of equipment commonly present on a ward, and potentially responsible for pathogen transfer, have been analyzed for potential issues of background fluorescence masking the signal from contaminant bacteria. These include bedside handrails, nurse call button, blood pressure cuff and ward computer keyboard, as well as disinfectant cleaning products and microfiber cloth. All examined bacterial strains exhibited a distinctive double-peak fluorescence feature associated with tryptophan with no other cellular fluorophore detected. Thus, this fluorescence survey found that an emission peak of 340nm, from an excitation source at 280nm, was the cellular fluorescence signal to target for detection of bacterial contamination. The majority of materials analysed offer a spectral window through which bacterial contamination could indeed be detected. A few instances were found of potential problems of background fluorescence masking that of bacteria, but in the case of the microfiber cleaning cloth, imaging techniques could morphologically distinguish between stray strands and bacterial contamination.
引用
收藏
页数:13
相关论文
共 49 条
  • [11] Experimental determination of photostability and fluorescence-based detection of PAHs on the Martian surface
    Dartnell, Lewis R.
    Patel, Manish R.
    Storrie-Lombardi, Michael C.
    Ward, John M.
    Muller, Jan-Peter
    [J]. METEORITICS & PLANETARY SCIENCE, 2012, 47 (05) : 806 - 819
  • [12] Degradation of Cyanobacterial Biosignatures by Ionizing Radiation
    Dartnell, Lewis R.
    Storrie-Lombardi, Michael C.
    Mullineaux, Conrad W.
    Ruban, Alexander V.
    Wright, Gary
    Griffiths, Andrew D.
    Muller, Jan-Peter
    Ward, John M.
    [J]. ASTROBIOLOGY, 2011, 11 (10) : 997 - 1016
  • [13] Complete fluorescent fingerprints of extremophilic and photosynthetic microbes
    Dartnell, Lewis R.
    Storrie-Lombardi, Michael C.
    Ward, John M.
    [J]. INTERNATIONAL JOURNAL OF ASTROBIOLOGY, 2010, 9 (04) : 245 - 257
  • [14] Autofluorescence characterization for the early diagnosis of neoplastic changes in DMBA/TPA-induced mouse skin carcinogenesis
    Diagaradjane, P
    Yaseen, MA
    Yu, J
    Wong, MS
    Anvari, B
    [J]. LASERS IN SURGERY AND MEDICINE, 2005, 37 (05) : 382 - 395
  • [15] Characterisation of the fluorescence from freshwater, planktonic bacteria
    Elliott, S.
    Lead, J. R.
    Baker, A.
    [J]. WATER RESEARCH, 2006, 40 (10) : 2075 - 2083
  • [16] Pseudomonas aeruginosa outbreak in a haematology-oncology unit associated with contaminated surface cleaning equipment
    Engelhart, S
    Krizek, L
    Glasmacher, A
    Fischnaller, E
    Marklein, G
    Exner, M
    [J]. JOURNAL OF HOSPITAL INFECTION, 2002, 52 (02) : 93 - 98
  • [17] Reagentless detection of microorganisms by intrinsic fluorescence
    Estes, C
    Duncan, A
    Wade, B
    Lloyd, C
    Ellis, W
    Powers, L
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (5-6) : 511 - 519
  • [18] Georgakoudi I, 2002, CANCER RES, V62, P682
  • [19] Rapid identification of bacterial species by fluorescence spectroscopy and classification through principal components analysis
    Giana, HE
    Silveira, L
    Zângaro, RA
    Pacheco, MTT
    [J]. JOURNAL OF FLUORESCENCE, 2003, 13 (06) : 489 - 493
  • [20] Reduction in acquisition of vancomycin-resistant enterococcus after enforcement of routine environmental cleaning measures
    Hayden, MK
    Bonten, MJM
    Blom, DW
    Lyle, EA
    van de Vijver, DAMC
    Weinstein, RA
    [J]. CLINICAL INFECTIOUS DISEASES, 2006, 42 (11) : 1552 - 1560