Analysis on reversible/irreversible electroporation region in lung adenocarcinoma cell model in vitro with electric pulses delivered by needle electrodes

被引:10
作者
Lv, Yanpeng [1 ]
Tang, Xiao [2 ]
Peng, Wencheng [2 ]
Cheng, Xian [1 ]
Chen, Shuo [1 ]
Yao, Chenguo [2 ]
机构
[1] Zhengzhou Univ, Sch Elect Engn, Zhengzhou 450001, Peoples R China
[2] Chongqing Univ, Sch Elect Engn, Chongqing 400030, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
irreversible electroporation; reversible electroporation; pulse number; tumor treatment; IRREVERSIBLE ELECTROPORATION; TISSUE ABLATION; DRUG-DELIVERY; ELECTROTRANSFER; FUNDAMENTALS;
D O I
10.1088/1361-6560/abc12e
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Irreversible electroporation (IRE) is a minimally invasive tumor therapy using pulsed electric field with high intensity while the important tissues such as blood vessel, bile duct, and nerve are preserved. In addition to ablation area, reversible electroporation (RE) region is also generated using needle electrodes for pulse delivery. The goal of this work is to study the generation of RE region and ablation region on a 2D lung adenocarcinoma cell model in vitro. The tumor model is exposed to electric pulses with various number. The calcium AM and propidium iodide (PI) are examined to detect the ablation area and electroporation area, respectively. The results show that electroporation area firstly tends to plateau after approximately 50 pulses, while the ablation area continues to increase. The percentage of IRE area in total electroporation area increases with additional pulses, which means that RE region could be gradually turned into ablation area with increased pulse number. However, the percentage of IRE area only achieves to 54% for 200 pulses, which indicates that RE region still cannot be completely removed. RE and IRE thresholds appear to converge as the number of pulses increases. An equation between pulse number and the electric field threshold of ablation including the electric field threshold of RE is also provided for lung adenocarcinoma cell ablation. This work may have the value for the optimization of IRE protocols on tumor ablation.
引用
收藏
页数:9
相关论文
共 29 条
[11]   Percutaneous Irreversible Electroporation for Downstaging and Control of Unresectable Pancreatic Adenocarcinoma [J].
Narayanan, Govindarajan ;
Hosein, Peter J. ;
Arora, Geetika ;
Barbery, Katuzka J. ;
Froud, Tatiana ;
Livingstone, Alan S. ;
Franceschi, Dido ;
Lima, Caio M. Rocha ;
Yrizarry, Jose .
JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (12) :1613-1621
[12]   In vivo Characterization and Numerical Simulation of Prostate Properties for Non-Thermal Irreversible Electroporation Ablation [J].
Neal, Robert E., II ;
Millar, Jeremy L. ;
Kavnoudias, Helen ;
Royce, Peter ;
Rosenfeldt, Franklin ;
Pham, Alan ;
Smith, Ryan ;
Davalos, Rafael V. ;
Thomson, Kenneth R. .
PROSTATE, 2014, 74 (05) :458-468
[13]   Experimental Characterization and Numerical Modeling of Tissue Electrical Conductivity during Pulsed Electric Fields for Irreversible Electroporation Treatment Planning [J].
Neal, Robert E., II ;
Garcia, Paulo A. ;
Robertson, John L. ;
Davalos, Rafael V. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (04) :1076-1085
[14]   Manipulation of cell volume and membrane pore comparison following single cell permeabilization with 60-and 600-ns electric pulses [J].
Nesin, Olena M. ;
Pakhomova, Olga N. ;
Xiao, Shu ;
Pakhomov, Andrei G. .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2011, 1808 (03) :792-801
[15]   Irreversible electroporation: Implications for prostate ablation [J].
Onik, Gary ;
Mikus, Paul ;
Rubinsky, Boris .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2007, 6 (04) :295-300
[16]   Multiple nanosecond electric pulses increase the number but not the size of long-lived nanopores in the cell membrane [J].
Pakhomov, Andrei G. ;
Gianulis, Elena ;
Vernier, P. Thomas ;
Semenov, Iurii ;
Xiao, Shu ;
Pakhomova, Olga N. .
BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2015, 1848 (04) :958-966
[17]   New Insights into the Mechanisms of Gene Electrotransfer - Experimental and Theoretical Analysis [J].
Pavlin, Mojca ;
Kanduser, Masa .
SCIENTIFIC REPORTS, 2015, 5
[18]   Modulating electrolytic tissue ablation with reversible electroporation pulses [J].
Phillips, Mary ;
Raju, Narayan ;
Rubinsky, Liel ;
Rubinsky, Boris .
TECHNOLOGY, 2015, 3 (01) :45-53
[19]   Irreversible electroporation: A new ablation modality - Clinical implications [J].
Rubinsky, Boris ;
Onik, Gary ;
Mikus, Paul .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2007, 6 (01) :37-48
[20]   Electrolytic Effects During Tissue Ablation by Electroporation [J].
Rubinsky, Liel ;
Guenther, Enric ;
Mikus, Paul ;
Stehling, Michael ;
Rubinsky, Boris .
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (05) :NP95-NP103