Comparison of different registration methods and landmarks for image-guided radiation therapy of pulmonary tumors

被引:4
作者
Cao, Xiaohui [1 ]
Liu, Ming [1 ]
Zhai, Fushan [1 ]
Li, Nan [1 ]
Bao, Chaoen [1 ]
Liu, Yinliang [1 ]
Chen, Gang [2 ]
机构
[1] Hebei Med Univ, Dept Radiotherapy & Oncol, Hosp 3, Shijiazhuang 050051, Hebei, Peoples R China
[2] Hebei Med Univ, Dept Resp Med, Hosp 3, 139 Ziqiang Rd, Shijiazhuang 050051, Hebei, Peoples R China
关键词
Cone beam computed tomography; Image-guided; Image registration; Lung cancer; BEAM COMPUTED-TOMOGRAPHY; LUNG-CANCER; RADIOTHERAPY; ACCURACY; CT; EPIDEMIOLOGY; MOTION; CHINA;
D O I
10.1186/s12880-019-0343-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: To compare the accuracy, advantages and disadvantages of automatic registration methods at different anatomical-sites for thoracic image-guided radiation therapy (IGRT). Methods: The Varian-IX IGRT system was used to perform a manual registration of the images collected on the first fraction of 60 patients with lung cancer (42 cases central location and 18 cases of peripheral). The registered images were used as reference images. Offline registration was performed for computed tomography-CBCT images using four methods: whole image registration, ipsilateral registration, soft tissue tumor registration, and vertebral body registration. Time taken to complete and deviation value were analyzed between the different methods. Results: There were significant differences in absolute deviation value of all the three directions (P < 0.001) and the time consumption (P < 0.001) between 4 methods. The Z direction had significant differences in deviation value of 4 methods (0.023 +/- 0.128 mm, - 0.030 +/- 0.175 mm, - 0.010 +/- 0.238 mm, - 0.075 +/- 0.137 mm, P = 0.011). The difference was significant in the X direction of the ipsilateral registration method between central and peripheral lung cancer (0.033 +/- 0.053 mm vs. 0.067 +/- 0.067 mm, P = 0.045). Conclusions: The whole lung or affected side registration methods could be recommended to be used in the automatic registration function of the Varian-IX's On-Board Imaging (OBI) system.
引用
收藏
页数:6
相关论文
共 24 条
  • [11] COMPARISON OF SPINE, CARINA, AND TUMOR AS REGISTRATION LANDMARKS FOR VOLUMETRIC IMAGE-GUIDED LUNG RADIOTHERAPY
    Higgins, Jane
    Bezjak, Andrea
    Franks, Kevin
    Le, Lisa W.
    Cho, B. C.
    Payne, David
    Bissonnette, Jean-Pierre
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (05): : 1404 - 1413
  • [12] Flat-panel cone-beam computed tomography for image-guided radiation therapy
    Jaffray, DA
    Siewerdsen, JH
    Wong, JW
    Martinez, AA
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05): : 1337 - 1349
  • [13] Cone Beam CT vs. Fan Beam CT: A Comparison of Image Quality and Dose Delivered Between Two Differing CT Imaging Modalities
    Lechuga, Lawrence
    Weidlich, Georg A.
    [J]. CUREUS, 2016, 8 (09):
  • [14] Evaluation of the Geometric Accuracy of Anatomic Landmarks as Surrogates for Intrapulmonary Tumors in Image-guided Radiotherapy
    Li, Hong-Sheng
    Kong, Ling-Ling
    Zhang, Jian
    Li, Bao-Sheng
    Chen, Jin-Hu
    Zhu, Jian
    Liu, Tong-Hai
    Yin, Yong
    [J]. ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2012, 13 (05) : 2393 - 2398
  • [15] Evaluation of Elekta 4D cone beam CT-based automatic image registration for radiation treatment of lung cancer
    Li, Jun
    Harrison, Amy
    Yu, Yan
    Xiao, Ying
    Werner-Wasik, Maria
    Lu, Bo
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1053)
  • [16] Use of megavoltage cine-images for studying intra-thoracic motion during radiotherapy for locally advanced lung cancer
    Muirhead, Rebecca
    van der Weide, Lineke
    de Koste, John R. van Sornsen
    Cover, Keith S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 (02) : 155 - 160
  • [17] Evaluation of setup accuracy for NSCLC patients; studying the impact of different types of cone-beam CT matches based on whole thorax, columna vertebralis, and GTV
    Ottosson, Wiviann
    Baker, Mariwan
    Hedman, Mattias
    Behrens, Claus F.
    Sjostrom, David
    [J]. ACTA ONCOLOGICA, 2010, 49 (07) : 1184 - 1191
  • [18] Radiation Therapy for Early Stage Lung Cancer
    Parashar, Bhupesh
    Arora, Shruthi
    Wernicke, A. Gabriella
    [J]. SEMINARS IN INTERVENTIONAL RADIOLOGY, 2013, 30 (02) : 185 - 190
  • [19] Comparison of manual vs. automated multimodality (CT-MRI) image registration for brain tumors
    Sarkar, A
    Santiago, RJ
    Smith, R
    Kassaee, A
    [J]. MEDICAL DOSIMETRY, 2005, 30 (01) : 20 - 24
  • [20] Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy
    Seppenwoolde, Y
    Shirato, H
    Kitamura, K
    Shimizu, S
    van Herk, M
    Lebesque, JV
    Miyasaka, K
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (04): : 822 - 834