Effect of an anionic polymer on the separation of cationic molecules by capillary electrophoresis with conductivity detection

被引:0
|
作者
Musial, BA [1 ]
Martin, MN [1 ]
Danielson, ND [1 ]
机构
[1] Miami Univ, Dept Chem & Biochem, Oxford, OH 45056 USA
来源
JOURNAL OF SEPARATION SCIENCE | 2002年 / 25卷 / 5-6期
关键词
poly(4-styrene sulfonate); organic amines; capillary electrophoresis;
D O I
10.1002/1615-9314(20020401)25:5/6<311::AID-JSSC311>3.0.CO;2-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Separations of quaternary amines tetramethylammonium (TMA(+)), 2-(chloroethyl)trimethylammonium (CIETMA(+)), tetraethylammonium (TEA(+)), tetrapropylammonium (TPA(+)), and tetrabutylammonium (TBA(+)), alkali metals potassium and sodium in the presence of choline, and alkyl-substituted ethylenediamine polyamines are examined using capillary electrophoresis at +25 kV with conductivity detection in 50 mM CHES electrolyte with poly(sodium 4-styrenesulfonate), PSSS, as a buffer additive. It is shown that the concentration of PSSS polyelectrolyte from 0.03 to 0.08% has a strong interaction with quaternary ammonium compounds, inducing a decrease in analyte electrophoretic mobility and improved resolution. For TPA(+) and TBA(+), using 0.03% PSSS, these changes are striking at about 33 and 60%, respectively. At the higher percentage of 0.08% PSSS, the TBA(+) peak actually migrated after the neutral marker. The change in the electropherograms due to PSSS is not due simply to viscosity but to an actual electrostatic and/or hydrophobic effect. The influence of the additives such as acetonitrile and sodium dodecyl sulfate (SDS) as well as PSSS in the buffer system on the electrophoretic behavior of alkali metals and choline is examined. Interaction of PSSS with Na+ is more pronounced than that for choline causing a decrease in peak spacing. Although a slight increase in all three analyte mobilities is noted, peak resolution is actually improved using SDS. Separation of structurally related polyamines is problematic with and without PSSS at acidic pH. Pre-rinsing the capillary with poly-L-glutamic acid (PGA) to ensure adsorption of PGA onto the capillary resulted in resolution improvement as well as sharper peaks for the polyamines.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [41] Design of Detection Electrode on Contactless Conductivity Detection in Capillary Electrophoresis Microchip
    Zhang, Haifeng
    Liu, Xiaowei
    Zhang, Xiaoshu
    Weng, Rui
    2013 8TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (IEEE NEMS 2013), 2013, : 1104 - 1107
  • [42] Separation of phosphorylated capillary electrophoresis with indirect photometric detection
    Schaeper, JP
    Shamsi, SA
    Danielson, ND
    JOURNAL OF CAPILLARY ELECTROPHORESIS, 1996, 3 (04) : 215 - 221
  • [43] The effect of anionic surfactant on poliovirus particles during capillary electrophoresis
    Oita, Iuliana
    Halewyck, Hadewych
    Thys, Bert
    Rombaut, Bart
    Vander Heyden, Yvan
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2012, 71 : 79 - 88
  • [44] A fast and reliable method for the determination of anionic impurities and neutralization agents in electrodipcoats using capillary zone electrophoresis with conductivity detection
    Klampfl, CW
    Katzmayr, MU
    Buchberger, W
    Basener, N
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1999, 22 (05): : 297 - 299
  • [45] Evaluation of the detection of biomolecules in capillary electrophoresis by contactless conductivity measurement
    Abad-Villar, Eva M.
    Kuban, Pavel
    Hauser, Peter C.
    JOURNAL OF SEPARATION SCIENCE, 2006, 29 (07) : 1031 - 1037
  • [46] Miniaturized movable contactless conductivity detection cell for capillary electrophoresis
    Macka, M
    Hutchinson, J
    Zemann, A
    Zhang, SS
    Haddad, PR
    ELECTROPHORESIS, 2003, 24 (12-13) : 2144 - 2149
  • [47] Separation and detection of peroxynitrite and its metabolites by capillary electrophoresis with UV detection
    Frankenfeld, CN
    Rosenbaugh, MR
    Fogarty, BA
    Lunte, SM
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1111 (02) : 147 - 152
  • [48] Conductivity detection in capillary electrophoresis - A powerful tool in ion analysis
    Haber, C
    Jones, WR
    Soglia, J
    Surve, MA
    McGlynn, M
    Caplan, A
    Reineck, JR
    Krstanovic, C
    JOURNAL OF CAPILLARY ELECTROPHORESIS, 1996, 3 (01) : 1 - 11
  • [49] Determination of PCR Products by Capillary Electrophoresis with Contactless Conductivity Detection
    Stojkovic, Marko
    Uda, Narasimha Rao
    Brodmann, Peter
    Hauser, Peter C.
    CHIMIA, 2013, 67 (06) : 428 - 428
  • [50] Analysis of fatty acids by capillary electrophoresis with contactless conductivity detection
    Oliveira, MAL
    do Lago, CL
    Tavares, MFM
    da Silva, JAF
    QUIMICA NOVA, 2003, 26 (06): : 821 - 824