Effect of an anionic polymer on the separation of cationic molecules by capillary electrophoresis with conductivity detection

被引:0
|
作者
Musial, BA [1 ]
Martin, MN [1 ]
Danielson, ND [1 ]
机构
[1] Miami Univ, Dept Chem & Biochem, Oxford, OH 45056 USA
来源
JOURNAL OF SEPARATION SCIENCE | 2002年 / 25卷 / 5-6期
关键词
poly(4-styrene sulfonate); organic amines; capillary electrophoresis;
D O I
10.1002/1615-9314(20020401)25:5/6<311::AID-JSSC311>3.0.CO;2-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Separations of quaternary amines tetramethylammonium (TMA(+)), 2-(chloroethyl)trimethylammonium (CIETMA(+)), tetraethylammonium (TEA(+)), tetrapropylammonium (TPA(+)), and tetrabutylammonium (TBA(+)), alkali metals potassium and sodium in the presence of choline, and alkyl-substituted ethylenediamine polyamines are examined using capillary electrophoresis at +25 kV with conductivity detection in 50 mM CHES electrolyte with poly(sodium 4-styrenesulfonate), PSSS, as a buffer additive. It is shown that the concentration of PSSS polyelectrolyte from 0.03 to 0.08% has a strong interaction with quaternary ammonium compounds, inducing a decrease in analyte electrophoretic mobility and improved resolution. For TPA(+) and TBA(+), using 0.03% PSSS, these changes are striking at about 33 and 60%, respectively. At the higher percentage of 0.08% PSSS, the TBA(+) peak actually migrated after the neutral marker. The change in the electropherograms due to PSSS is not due simply to viscosity but to an actual electrostatic and/or hydrophobic effect. The influence of the additives such as acetonitrile and sodium dodecyl sulfate (SDS) as well as PSSS in the buffer system on the electrophoretic behavior of alkali metals and choline is examined. Interaction of PSSS with Na+ is more pronounced than that for choline causing a decrease in peak spacing. Although a slight increase in all three analyte mobilities is noted, peak resolution is actually improved using SDS. Separation of structurally related polyamines is problematic with and without PSSS at acidic pH. Pre-rinsing the capillary with poly-L-glutamic acid (PGA) to ensure adsorption of PGA onto the capillary resulted in resolution improvement as well as sharper peaks for the polyamines.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [21] Separation of deoxyribonucleic acid by capillary electrophoresis in polymer solutions
    Jin, Y
    Lin, BC
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (01) : 111 - 117
  • [22] Separation of twenty underivatized essential amino acids by capillary zone electrophoresis with contactless conductivity detection
    Coufal, P
    Zuska, J
    van de Goor, T
    Smith, V
    Gas, B
    ELECTROPHORESIS, 2003, 24 (04) : 671 - 677
  • [23] Separation of inorganic and organic anions by capillary zone electrophoresis with simultaneous indirect UV and conductivity detection
    Klampfl, CW
    Katzmayr, MU
    Buchberger, W
    ELECTROPHORESIS, 1998, 19 (14) : 2459 - 2464
  • [24] The ephedrine and pseudoephedrine separation with the capillary electrophoresis and determination by conductivity detector
    Zheng, YN
    Xie, TY
    Mo, JY
    Wei, SL
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2002, 23 (02): : 199 - 202
  • [25] Investigating cationic and zwitterionic successive multiple ionic-polymer layer coatings for protein separation by capillary electrophoresis
    Dhellemmes, Laura
    Leclercq, Laurent
    Frick, Henry
    Hoechsmann, Alisa
    Schaschke, Norbert
    Neusuess, Christian
    Cottet, Herve
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1720
  • [26] Capacitively Coupled Contactless Conductivity Detection in Capillary Electrophoresis
    Tan Feng
    Guan Yafeng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (02) : 152 - 157
  • [27] Capacitively coupled contactless conductivity detection in capillary electrophoresis
    Zemann, AJ
    ELECTROPHORESIS, 2003, 24 (12-13) : 2125 - 2137
  • [28] A Spectroscopy Solution for Contactless Conductivity Detection in Capillary Electrophoresis
    Drevinskas, Tomas
    Maruska, Audrius
    Ihara, Hirotaka
    Takafuji, Makoto
    Jonusauskas, Linas
    Armonavicius, Domantas
    Stankevicius, Mantas
    Bimbiraite-Surviliene, Kristina
    Skrzydlewska, Elzbieta
    Ragazinskiene, Ona
    Kuwahara, Yutaka
    Nagaoka, Shoji
    Kaskoniene, Vilma
    Kubiliene, Loreta
    MICROMACHINES, 2024, 15 (12)
  • [29] Cationic cyclodextrin as versatile chiral selector for enantiomeric separation in capillary electrophoresis
    Dai, Yun
    Wang, Shuye
    Zhou, Jie
    Liu, Yun
    Sun, Dongping
    Tang, Jian
    Tang, Weihua
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1246 : 98 - 102
  • [30] Conductivity detection for conventional and miniaturised capillary electrophoresis systems
    Guijt, RM
    Evenhuis, CJ
    Macka, M
    Haddad, PR
    ELECTROPHORESIS, 2004, 25 (23-24) : 4032 - 4057