Mapping single-nephron filtration in the isolated, perfused rat kidney using magnetic resonance imaging

被引:0
作者
Baldelomar, Edwin J. [1 ]
Charlton, Jennifer R. [2 ]
Bennett, Kevin M. [1 ]
机构
[1] Washington Univ, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
[2] Univ Virginia, Div Nephrol, Dept Pediat, Charlottesville, VA USA
基金
美国国家卫生研究院;
关键词
cationized ferritin; kidney physiology; magnetic resonance imaging; single-nephron glomerular filtration rate; GLOMERULAR NUMBER; MRI; MICROPUNCTURE; LIMITATIONS; PATHOLOGY; INJURY; SIZE;
D O I
10.1152/ajprenal.00103.2022
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The kidney has an extraordinary ability to maintain glomerular filtration despite natural fluctuations in blood pressure and nephron loss. This is partly due to local coordination between single-nephron filtration and vascular perfusion. An improved understanding of the three-dimensional (3-D) functional coordination between nephrons and the vasculature may provide a new perspective of the heterogeneity of kidney function and could inform targeted therapies and timed interventions to slow or prevent the progression of kidney disease. Here, we developed magnetic resonance imaging (MRI) tools to visualize single-nephron function in 3-D throughout the isolated perfused rat kidney. We used an intravenous slow perfusion of a glomerulus-targeted imaging tracer [cationized ferritin (CF)] to map macromolecular dynamics and to identify glomeruli in 3-D, followed by a bolus of a freely filtered tracer (gadolinium diethylenetriamine penta-acetic acid) to map filtration kinetics. There was a wide intrakidney distribution of CF binding rates and estimated single-nephron glomerular filtration rate (eSNGFR) between nephrons. eSNGFR and CF uptake rates did not vary significantly by distance from the kidney surface. eSNGFR varied from similar to 10 to similar to 100 nL/min throughout the kidney. Whole single-kidney GFR was similar across all kidneys, despite differences in the distributions eSNGFR of and glomerular number, indicating a robust adaptive regulation of individual nephrons to maintain constant single-kidney GFR in the presence of a natural variation in nephron number. This work provides a framework for future studies of single-nephron function in the whole isolated perfused kidney and experiments of single-nephron function in vivo using MRI. NEW & NOTEWORTHY We report MRI tools to measure and map single-nephron function in the isolated, perfused rat kidney. We used imaging tracers to identify nephrons throughout the kidney and to measure the delivery and filtration of the tracers at the location of the glomeruli. With this technique, we directly measured physiological parameters including estimated single-nephron glomerular filtration rate throughout the kidney. This work provides a foundation for new studies to simultaneously map the function of large numbers of nephrons.
引用
收藏
页码:F602 / F611
页数:10
相关论文
共 50 条
  • [31] Spatiotemporal mapping of brain atrophy in mouse models of Huntington's disease using longitudinal in vivo magnetic resonance imaging
    Aggarwal, Manisha
    Duan, Wenzhen
    Hou, Zhipeng
    Rakesh, Neal
    Peng, Qi
    Ross, Christopher A.
    Miller, Michael I.
    Mori, Susumu
    Zhang, Jiangyang
    NEUROIMAGE, 2012, 60 (04) : 2086 - 2095
  • [32] Molecular Imaging of Tumors Using a Quantitative T-1 Mapping Technique via Magnetic Resonance Imaging
    Herrmann, Kelsey
    Johansen, Mette L.
    Craig, Sonya E.
    Vincent, Jason
    Howell, Michael
    Gao, Ying
    Lu, Lan
    Erokwu, Bernadette
    Agnes, Richard S.
    Lu, Zheng-Rong
    Pokorski, Jonathan K.
    Basilion, James
    Gulani, Vikas
    Griswold, Mark
    Flask, Chris
    Brady-Kalnay, Susann M.
    DIAGNOSTICS, 2015, 5 (03): : 318 - 332
  • [33] A rapid T1 mapping method for assessment of murine kidney viability using dynamic manganese-enhanced magnetic resonance imaging
    Jiang, Kai
    Tang, Hui
    Mishra, Prasanna K.
    Macura, Slobodan I.
    Lerman, Lilach O.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 190 - 199
  • [34] ASSESSMENT OF MYOCARDIAL PERFUSION DURING ISCHEMIA AND REPERFUSION IN ISOLATED RAT HEARTS USING GADOPENTETIC ACID ENHANCED MAGNETIC-RESONANCE-IMAGING
    HOLMAN, ER
    VANDIJKMAN, PRM
    VANDERWALL, EE
    MATHEIJSSEN, NAA
    VANDERMEER, P
    VANECHTELD, CJA
    RUIGROK, TJC
    DEROOS, A
    VANDERLAARSE, A
    CORONARY ARTERY DISEASE, 1991, 2 (07) : 789 - 797
  • [35] Noninvasive Diagnosis of Kidney Dysfunction Using a Small-Molecule Manganese-Based Magnetic Resonance Imaging Probe
    Zhang, Yuping
    Xiang, Ke
    Pan, Jinbin
    Cheng, Ran
    Sun, Shao-Kai
    ANALYTICAL CHEMISTRY, 2024, 96 (08) : 3318 - 3328
  • [36] Diffusion-weighted magnetic resonance imaging in rat kidney using two-dimensional navigated, interleaved echo-planar imaging at 7.0 T
    Liu, Qiang
    Xu, Zhongbiao
    Zhao, Kaixuan
    Hoge, W. Scott
    Zhang, Xinyuan
    Mei, Yingjie
    Lu, Qiqi
    Niendorf, Thoralf
    Feng, Yanqiu
    NMR IN BIOMEDICINE, 2022, 35 (05)
  • [37] Quantitative mapping of glenohumeral cartilage in asymptomatic subjects using 3 T magnetic resonance imaging
    Lockard, Carly A.
    Wilson, Katharine J.
    Ho, Charles P.
    Shin, Richard C.
    Katthagen, J. Christoph
    Millett, Peter J.
    SKELETAL RADIOLOGY, 2018, 47 (05) : 671 - 682
  • [38] TEMPERATURE MAPPING IN CARROT USING T-1 WEIGHTED MAGNETIC-RESONANCE-IMAGING
    HULBERT, GJ
    LITCHFIELD, JB
    SCHMIDT, SJ
    JOURNAL OF FOOD SCIENCE, 1995, 60 (04) : 780 - 785
  • [39] Mapping cortical areas associated with Chinese word processing using functional magnetic resonance imaging
    Ma, L
    Tang, YY
    Wang, Y
    Li, DJ
    Weng, XC
    Zhang, WT
    Zhuang, JC
    Hu, XP
    CHINESE MEDICAL JOURNAL, 2003, 116 (02) : 176 - 180
  • [40] Mapping of the fluid distribution in impregnated reinforcement textiles using Magnetic Resonance Imaging: Methods and issues
    Endruweit, Andreas
    Glover, Paul
    Head, Kay
    Long, Andrew C.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2011, 42 (03) : 265 - 273