Evaluating a suitable level of model complexity for finite element analysis of the intact acetabulum

被引:36
作者
Clarke, S. G. [1 ]
Phillips, A. T. M. [1 ]
Bull, A. M. J. [2 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Civil & Environm Engn, London, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London, England
基金
英国工程与自然科学研究理事会;
关键词
finite element analysis; acetabulum; sensitivity; HUMAN ARTICULAR-CARTILAGE; HIP-JOINT; CONTACT FORCES; LOAD-TRANSFER; BONE; PELVIS; VALIDATION; FIXATION; FEMUR; ORIENTATION;
D O I
10.1080/10255842.2011.633906
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To enable large-scale multi-factorial finite element (FE) studies, the FE models used must be as computationally efficient as is feasible, while maintaining a suitable level of definition. The present study seeks to find an optimum level of model complexity for use in such large-scale studies by investigating which model attributes are most influential over the chosen model outputs of principal stress and strain in the intact acetabulum. A multi-factorial sensitivity study was carried out using 128 FE models, representing combinations of the following variables: bone stiffness distribution, imposed muscle loading, boundary condition location, hip joint contact conditions and patient's bone anatomy. The relative sensitivity of each input factor was analysed, and it was concluded that the optimum level of model definition must include CT-dependent trabecular bone properties and a sliding interface at the hip joint. It was found that it was not essential to describe the ligamentous sacroiliac and pubic symphysis joints; these could be rigidly fixed in space; and for the normal walking load case, muscle forces may be neglected. It was also concluded that a variety of bone anatomies should be included in a multi-factorial analysis if results are to be inferred for a wider population.
引用
收藏
页码:717 / 724
页数:8
相关论文
共 44 条
[21]   A convenient approach for finite-element-analyses of orthopaedic implants in bone contact: Modeling and experimental validation [J].
Kluess, Daniel ;
Souffrant, Robert ;
Mittelmeier, Wolfram ;
Wree, Andreas ;
Schmitz, Klaus-Peter ;
Bader, Rainer .
COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2009, 95 (01) :23-30
[22]   A review of probabilistic analysis in orthopaedic biomechanics [J].
Laz, P. J. ;
Browne, M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2010, 224 (H8) :927-943
[23]   Simulation of hip fracture in sideways fall using a 3D finite element model of pelvis-femur-soft tissue complex with simplified representation of whole body [J].
Majumder, Santanu ;
Roychowdhury, Amit ;
Pal, Subrata .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) :1167-1178
[24]   A parametric study of acetabular cup design variables using finite element analysis and statistical design of experiments [J].
Mantell, SC ;
Chanda, H ;
Bechtold, JE ;
Kyle, RF .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1998, 120 (05) :667-675
[25]   Optimizing the configuration of cement keyholes for acetabular fixation in total hip replacement using Taguchi experimental design [J].
Mburu, G ;
Aspden, RM ;
Hutchison, JD .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1999, 213 (H6) :485-492
[26]   Variations in acetabular anatomy with reference to total hip replacement [J].
Murtha, P. E. ;
Hafez, M. A. ;
Jaramaz, B. ;
DiGioia, A. M., III .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (03) :308-313
[27]   MECHANICAL ANALYSIS OF THE HUMAN PELVIS AND ITS APPLICATION TO THE ARTIFICIAL HIP-JOINT BY MEANS OF THE 3-DIMENSIONAL FINITE-ELEMENT METHOD [J].
OONISHI, H ;
ISHA, H ;
HASEGAWA, T .
JOURNAL OF BIOMECHANICS, 1983, 16 (06) :427-444
[28]   Finite element modelling of the pelvis: Inclusion of muscular and ligamentous boundary conditions [J].
Phillips, A. T. M. ;
Pankaj, P. ;
Howie, C. R. ;
Usmani, A. S. ;
Simpson, A. H. R. W. .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (07) :739-748
[29]   Determination of suitable sample sizes for multi-patient based finite element studies [J].
Radcliffe, I. A. J. ;
Prescott, P. ;
Man, H. S. ;
Taylor, M. .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (10) :1065-1072
[30]   Investigation into the effect of varus-valgus orientation on load transfer in the resurfaced femoral head: A multi-femur finite element analysis [J].
Radcliffe, I. A. J. ;
Taylor, M. .
CLINICAL BIOMECHANICS, 2007, 22 (07) :780-786