Evaluating a suitable level of model complexity for finite element analysis of the intact acetabulum

被引:35
作者
Clarke, S. G. [1 ]
Phillips, A. T. M. [1 ]
Bull, A. M. J. [2 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Civil & Environm Engn, London, England
[2] Univ London Imperial Coll Sci Technol & Med, Dept Bioengn, London, England
基金
英国工程与自然科学研究理事会;
关键词
finite element analysis; acetabulum; sensitivity; HUMAN ARTICULAR-CARTILAGE; HIP-JOINT; CONTACT FORCES; LOAD-TRANSFER; BONE; PELVIS; VALIDATION; FIXATION; FEMUR; ORIENTATION;
D O I
10.1080/10255842.2011.633906
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To enable large-scale multi-factorial finite element (FE) studies, the FE models used must be as computationally efficient as is feasible, while maintaining a suitable level of definition. The present study seeks to find an optimum level of model complexity for use in such large-scale studies by investigating which model attributes are most influential over the chosen model outputs of principal stress and strain in the intact acetabulum. A multi-factorial sensitivity study was carried out using 128 FE models, representing combinations of the following variables: bone stiffness distribution, imposed muscle loading, boundary condition location, hip joint contact conditions and patient's bone anatomy. The relative sensitivity of each input factor was analysed, and it was concluded that the optimum level of model definition must include CT-dependent trabecular bone properties and a sliding interface at the hip joint. It was found that it was not essential to describe the ligamentous sacroiliac and pubic symphysis joints; these could be rigidly fixed in space; and for the normal walking load case, muscle forces may be neglected. It was also concluded that a variety of bone anatomies should be included in a multi-factorial analysis if results are to be inferred for a wider population.
引用
收藏
页码:717 / 724
页数:8
相关论文
共 44 条
  • [1] Subject-specific finite element model of the pelvis: Development, validation and sensitivity studies
    Anderson, AE
    Peters, CL
    Tuttle, BD
    Weiss, JA
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (03): : 364 - 373
  • [2] Anderson Andrew E., 2007, Computer Methods in Biomechanics and Biomedical Engineering, V10, P171, DOI 10.1080/10255840601160484
  • [3] [Anonymous], GRAYS ANATOMY ANATOM
  • [4] Hip contact forces and gait patterns from routine activities
    Bergmann, G
    Deuretzbacher, G
    Heller, M
    Graichen, F
    Rohlmann, A
    Strauss, J
    Duda, GN
    [J]. JOURNAL OF BIOMECHANICS, 2001, 34 (07) : 859 - 871
  • [5] Elastic and viscoelastic properties of the human pubic symphysis joint: Effects of lateral impact loading
    Dakin, GJ
    Arbelaez, RA
    Molz, FJ
    Alonso, JE
    Mann, KA
    Eberhardt, AW
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (03): : 218 - 226
  • [6] MECHANICAL AND TEXTURAL PROPERTIES OF PELVIC TRABECULAR BONE
    DALSTRA, M
    HUISKES, R
    ODGAARD, A
    VANERNING, L
    [J]. JOURNAL OF BIOMECHANICS, 1993, 26 (4-5) : 523 - 535
  • [7] LOAD-TRANSFER ACROSS THE PELVIC BONE
    DALSTRA, M
    HUISKES, R
    [J]. JOURNAL OF BIOMECHANICS, 1995, 28 (06) : 715 - 724
  • [8] The shape of acetabular cartilage optimizes hip contact stress distribution
    Daniel, M
    Iglic, A
    Kralj-Iglic, V
    [J]. JOURNAL OF ANATOMY, 2005, 207 (01) : 85 - 91
  • [9] Statistical methods in finite element analysis
    Dar, FH
    Meakin, JR
    Aspden, RM
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (09) : 1155 - 1161
  • [10] The relationship between hip joint space width, center edge angle and acetabular depth
    Daysal, G. A.
    Goker, B.
    Gonen, E.
    Demirag, M. D.
    Haznedaroglu, S.
    Ozturk, M. A.
    Block, J. A.
    [J]. OSTEOARTHRITIS AND CARTILAGE, 2007, 15 (12) : 1446 - 1451