Quantitative imaging with the micro-pet small-animal pet tomograph

被引:18
|
作者
Vaska, Paul [1 ]
Rubins, Daniel J.
Alexoff, David L.
Schiffert, Wynne K.
机构
[1] Brookhaven Natl Lab, Dept Med, Upton, NY 11973 USA
[2] Brookhaven Natl Lab, Ctr Translat Neuroimaging, Upton, NY 11973 USA
[3] Merck & Co Inc, Merck Res Labs, Dept Imaging, West Point, PA 19486 USA
[4] Brookhaven Natl Lab, Dept Chem, Upton, NY 11973 USA
来源
INTERNATIONAL REVIEW OF NEUROBIOLOGY, VOL 73 | 2006年 / 73卷
关键词
D O I
10.1016/S0074-7742(06)73006-9
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Quantitative imaging of complex biological processes is a critical technology of the post-sequencing era. In particular, positron emission tomography (PET), using small-animal models, has emerged as a powerful technique to explore physiology in a flexible, noninvasive, and potentially highly, quantitative way. With the recent advent of commercial high-resolution, small-animal imagers, such as the micro-PET scanners from Siemens (formerly Concorde Microsystems), functional imaging of rodent models using PET has found increasing acceptance. However, a broad class of PET research, particularly neuroimaging, requires quantitative accuracy which, for the new small-animal systems, has generally been slow to reach the standards of state-of-the-art clinical research cameras. An essential first step in a quantitative PET study is the generation of a faithful representation of the radioactivity distribution in the subject as a function of time, which can be subsequently interpreted in terms of biological processes using methods such as tracer kinetic modeling. Since the accuracy of the input images is critical to the effectiveness of such models, the development of methods to improve image quantification is an important endeavor. These issues in the physics of imaging comprise the focus of this manuscript. Many factors impact PET image quantification including system setup and calibration, prereconstruction corrections for physical effects (e.g., deadtime, randoms, scatter, and attenuation), the type of image reconstruction algorithm, and postreconstruction methods that delineate anatomical regions and correct for spatial-resolution effects (i.e., partial volume effects). While most of these quantitative issues are applicable to all small-animal PET systems, they will be described in the specific context of the popular micro-PET R4 rodent tomograph in order to provide concrete recommendations.
引用
收藏
页码:191 / +
页数:35
相关论文
共 50 条
  • [21] In vivo imaging of β-amyloid transgenic mouse models by small-animal PET
    Maeda, Jun
    Higuchi, Makoto
    Suhara, Testuya
    YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2008, 128 : 157 - 159
  • [22] Scatter Characterization and Correction for Simultaneous Multiple Small-Animal PET Imaging
    Rameshwar Prasad
    Habib Zaidi
    Molecular Imaging and Biology, 2014, 16 : 199 - 209
  • [23] Longitudinal correlations in a small-animal PET studies
    Abbey, C
    Borowsky, A
    Gregg, J
    McGoldrick, E
    Cardiff, R
    Cherry, S
    MEDICAL PHYSICS, 2005, 32 (06) : 1901 - 1901
  • [24] Semiautomated analysis of small-animal PET data
    Kesner, Adam L.
    Dahlbom, Magnus
    Huang, Sung-Cheng
    Hsueh, Wei-Ann
    Pio, Betty S.
    Czernin, Johannes
    Kreissl, Michael
    Wu, Hsiao-Ming
    Silverman, Daniel H. S.
    JOURNAL OF NUCLEAR MEDICINE, 2006, 47 (07) : 1181 - 1186
  • [25] Quantitative small animal PET imaging with nonconventional nuclides
    Liu, Xiaodong
    Laforest, Richard
    NUCLEAR MEDICINE AND BIOLOGY, 2009, 36 (05) : 551 - 559
  • [26] The future of hybrid imaging—part 3: PET/MR, small-animal imaging and beyond
    Thomas Beyer
    Lutz S. Freudenberg
    Johannes Czernin
    David W. Townsend
    Insights into Imaging, 2011, 2 (3) : 235 - 246
  • [27] Quantitative small animal PET
    Shoghi, K. I.
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 53 (04): : 365 - 373
  • [28] Positron range effects of 66Ga in small-animal PET imaging
    Rodriguez-Villafuerte, M.
    Hernandez, E. M.
    Alva-Sanchez, H.
    Martinez-Davalos, A.
    Avila-Rodriguez, M. A.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 67 : 50 - 57
  • [29] High performance of an integrated PET/SPECT/CT system for small-animal imaging
    Magota, Keiichi
    Kubo, Naoki
    Kuge, Yuji
    Nishijima, Ken-ichi
    Zhao, Songji
    Tamaki, Nagara
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [30] Assessment of iterative image reconstruction techniques for small-animal PET imaging applications
    Karali, E.
    Pavlopoulos, S.
    Koutsouris, D.
    8TH IEEE INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING, VOLS 1 AND 2, 2008, : 948 - 953