Chloride determination by ion chromatography in petroleum coke after digestion by microwave-induced combustion
被引:70
作者:
Pereira, Juliana S. F.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, BrazilUniv Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
Pereira, Juliana S. F.
[1
]
Diehl, Liange O.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, BrazilUniv Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
Diehl, Liange O.
[1
]
Duarte, Fabio A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, BrazilUniv Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
Duarte, Fabio A.
[1
]
Santos, Maria F. P.
论文数: 0引用数: 0
h-index: 0
机构:
Ctr Pesquisas & Desenvolvimento Leopoldo Amer Mig, BR-21941945 Rio De Janeiro, BrazilUniv Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
Santos, Maria F. P.
[2
]
Guimaraes, Regina C. L.
论文数: 0引用数: 0
h-index: 0
机构:
Ctr Pesquisas & Desenvolvimento Leopoldo Amer Mig, BR-21941945 Rio De Janeiro, BrazilUniv Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
Guimaraes, Regina C. L.
[2
]
Dressler, Valderi L.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, BrazilUniv Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
Dressler, Valderi L.
[1
]
Flores, Erico M. M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, BrazilUniv Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
Flores, Erico M. M.
[1
]
机构:
[1] Univ Fed Santa Maria, Dept Quim, BR-97105900 Santa Maria, RS, Brazil
[2] Ctr Pesquisas & Desenvolvimento Leopoldo Amer Mig, BR-21941945 Rio De Janeiro, Brazil
Microwave-induced combustion;
Petroleum coke;
Chloride;
Ion chromatography;
D O I:
10.1016/j.chroma.2008.10.079
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Microwave-induced combustion was applied to petroleum coke digestion in closed vessels for further chloride determination by ion chromatography. Samples were pressed as pellets and placed on a quartz holder. Combustion was performed using oxygen pressure of 2 MPa and 50 mu l of 6mol1(-1) NH4NO3 as aid for ignition. Recoveries from 97 to 102% were obtained for all studied absorbing solutions (water, H2O2, Na2CO3 or(NH4)2CO(3)). Accuracy was evaluated using certified reference materials with agreement better than 98% using water as absorbing solution with reflux step. The limit of quantification was 3.8 mu gg(-1). (c) 2008 Elsevier B.V. All rights reserved.