Life Cycle Assessment performance comparison of small solar thermal cooling systems with conventional plants assisted with photovoltaics

被引:24
作者
Beccali, Marco [1 ]
Cellura, Maurizio [1 ]
Finocchiaro, Pietro [1 ]
Guarino, Francesco [1 ]
Longo, Sonia [1 ]
Nocke, Bettina [1 ]
机构
[1] Univ Palermo, Dipartimento Energia, I-90128 Palermo, Italy
来源
1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012) | 2012年 / 30卷
关键词
Solar Cooling; Life Cycle Assessment; Photovoltaics;
D O I
10.1016/j.egypro.2012.11.101
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Life Cycle Assessment (LCA) allows for the consideration of energy consumption and environmental impacts associated with all the stages of a product's life, from the cradle to the grave. Starting from the results obtained in the IEA SHC Task 38 framework for the LCA of small solar assisted heat driven chillers, the application of such methodology has been extended to systems with a conventional compression chiller assisted by a photovoltaic plant. This study aims to provide a more comprehensive investigation through a comparison of these two families of solar assisted cooling systems (with solar thermal or PV), which is an important topic for studies concerning the research of effective and environmentally friendly systems that exploit solar radiation for cooling and heating purposes. In hot climates, the systems with the PV grid connected plant performed best. Anyway, a comparison of this system with the other systems is not meaningful because the strength of the solar thermal H/C system is the ability to reduce the dependence from the electric grid and to avoid peaks, overloads and power quality variations. Thus, two more configurations were investigated to further define the PV assisted systems, which minimise their interaction with the grid through the use of electricity storages. These systems performed worse than the PV grid connected systems and the solar thermal assisted systems in nearly all the analysed cases. (C) 2012 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:893 / 903
页数:11
相关论文
共 12 条
[1]  
[Anonymous], 2006, 14040 ISO
[2]  
[Anonymous], 2012, SIMAPRO7 ENV DAT
[3]  
[Anonymous], LIFE CYCLE ASSESSMEN
[4]  
[Anonymous], 2006, 14044 ISO
[5]   FALCADE: a fuzzy software for the energy and environmental balances of products [J].
Ardente, F ;
Beccali, M ;
Cellura, M .
ECOLOGICAL MODELLING, 2004, 176 (3-4) :359-379
[6]   Evaluation of technical improvements of photovoltaic systems through life cycle assessment methodology [J].
Battisti, R ;
Corrado, A .
ENERGY, 2005, 30 (07) :952-967
[7]   LCA of a solar heating and cooling system equipped with a small water-ammonia absorption chiller [J].
Beccali, Marco ;
Cellura, Maurizio ;
Longo, Sonia ;
Nocke, Bettina ;
Finocchiaro, Pietro .
SOLAR ENERGY, 2012, 86 (05) :1491-1503
[8]  
Frischknecht R., 2007, OVERVIEW METHODOLOGY
[9]   Life cycle assessment study of a 4.2 kWp stand-alone photovoltaic system [J].
Garcia-Valverde, R. ;
Miguel, C. ;
Martinez-Bejar, R. ;
Urbina, A. .
SOLAR ENERGY, 2009, 83 (09) :1434-1445
[10]   Life cycle assessment study of solar PV systems:: An example of a 2.7 kWp distributed solar PV system in Singapore [J].
Kannan, R. ;
Leong, K. C. ;
Osman, R. ;
Ho, H. K. ;
Tso, C. P. .
SOLAR ENERGY, 2006, 80 (05) :555-563