Fiber optic sensor for the measurement of respiratory chest circumference changes

被引:33
作者
Babchenko, A [1 ]
Khanokh, B [1 ]
Shomer, Y [1 ]
Nitzan, M [1 ]
机构
[1] Jerusalem Coll Technol, Dept Appl Phys Electroopt, IL-91160 Jerusalem, Israel
关键词
fiber optic sensor; respiratory depth measurement; photoplethysmography;
D O I
10.1117/1.429909
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A fiber optic sensor for the measurement of the respiratory depth has been developed. The sensor is composed of a bent optic fiber which is connected to an elastic section of a chest belt so that its radius of curvature changes during respiration due to respiratory chest circumference changes (RCCC). The measurement of light transmission through the bent fiber provides information on its changes in curvature since a higher fraction of Light escapes through the core-cladding surface of a fiber bent to a lower radius of curvature. The sensor can quantitatively measure the RCCC, although in relative terms, and it is sensitive enough to detect changes of the chest circumference due to the heart beat. Measurements of the RCCC were simultaneously performed with photoplethysmography (PPG)-the measurement by light absorption of the cardiac induced blood volume changes in the tissue-and a significant correlation was found between the RCCC and some parameters of the PPG signal. The fiber optic respiratory depth sensor enables a quantitative assessment of the respiratory induced changes in the cardiovascular parameters, (C) 1999 Society of Photo-Optical Instrumentation Engineers. [S1083-3668(99)00402-5].
引用
收藏
页码:224 / 229
页数:6
相关论文
共 29 条
[1]   REMOTE FIBER-OPTIC BIOSENSORS BASED ON EVANESCENT-EXCITED FLUORO-IMMUNOASSAY - CONCEPT AND PROGRESS [J].
ANDRADE, JD ;
VANWAGENEN, RA ;
GREGONIS, DE ;
NEWBY, K ;
LIN, JN .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1985, 32 (07) :1175-1179
[2]  
ANTONIOSANTIAGO MT, 1990, PULMONARY PHYSL FETU, pCH20
[3]  
Artjushenko V. G., 1995, Proceedings of the SPIE - The International Society for Optical Engineering, V2631, P92, DOI 10.1117/12.229171
[4]   BEND LOSS IN LARGE CORE MULTIMODE OPTICAL FIBER BEAM DELIVERY SYSTEMS [J].
BOECHAT, AAP ;
SU, DN ;
HALL, DR ;
JONES, JDC .
APPLIED OPTICS, 1991, 30 (03) :321-327
[5]   SINGLE FIBER LASER-DOPPLER FLOWMETRY-DEPENDENCE ON WAVELENGTH AND TIP OPTICS [J].
Cai, Hongming ;
Larsson, Sven-Erik ;
Oberg, P. Ake .
JOURNAL OF BIOMEDICAL OPTICS, 1998, 3 (03) :334-339
[6]   PHOTOELECTRIC PLETHYSMOGRAPH FOR MEASUREMENT OF CUTANEOUS BLOOD-FLOW [J].
CHALLONER, AV ;
RAMSAY, CA .
PHYSICS IN MEDICINE AND BIOLOGY, 1974, 19 (03) :317-328
[7]   A CAUSAL RELATIONSHIP BETWEEN FLUCTUATIONS IN THERMOREGULATORY SKIN PERFUSION AND RESPIRATORY MOVEMENTS IN MAN [J].
ERIKSEN, M ;
LOSSIUS, K .
JOURNAL OF THE AUTONOMIC NERVOUS SYSTEM, 1995, 53 (2-3) :223-229
[8]  
FRONEK A, 1989, NONINVASIVE DIAGNOST, P22
[9]   OPTICAL FLUORESCENCE AND ITS APPLICATION TO AN INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM [J].
GEHRICH, JL ;
LUBBERS, DW ;
OPITZ, N ;
HANSMANN, DR ;
MILLER, WW ;
TUSA, JK ;
YAFUSO, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :117-132
[10]   SURFACE-MOUNTED OPTICAL FIBER STRAIN SENSOR DESIGN [J].
HASLACH, HW ;
SIRKIS, JS .
APPLIED OPTICS, 1991, 30 (28) :4069-4080