Sensitive electrochemical detection of cardiac troponin I in serum and saliva by nitrogen-doped porous reduced graphene oxide electrode

被引:105
作者
Chekin, Fereshteh [1 ,2 ]
Vasilescu, Alina [3 ]
Jijie, Roxana [2 ]
Singh, Santosh K. [4 ]
Kurungot, Sreekumar [4 ,5 ]
Iancu, Madalina [6 ]
Badea, Gabriela [6 ]
Boukherroub, Rabah [2 ]
Szunerits, Sabine [2 ]
机构
[1] Islamic Azad Univ, Ayatollah Amoli Branch, Dept Chem, Amol, Iran
[2] Univ Valenciennes, Univ Lille, CNRS, Cent Lille,ISEN,IEMN,UMR 8520, F-59000 Lille, France
[3] Int Ctr Biodynam, 1B Intrarea Portocalelor,Sect 6, Bucharest 060101, Romania
[4] CSIR, Natl Chem Lab, Phys & Mat Chem Div, Dr Homi Bhabha Rd, Pune 411008, Maharashtra, India
[5] Acad Sci & Innovat Res, Anusandhan Bhawan,2 RafiMarg, New Delhi 110001, India
[6] Agrippa Ionescu Emergency Clin Hosp, 7 Ion Mincu, Bucharest 011356, Romania
关键词
Cardiac troponin I; Electrochemical biosensor; Aptamer; Pyrene; Nitrogen-doped porous reduced graphene oxide; LABEL-FREE DETECTION; CARBON NANOTUBES; IMMUNOSENSOR; REDUCTION; FUNCTIONALIZATION; NANOPARTICLES;
D O I
10.1016/j.snb.2018.01.215
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cardiovascular diseases pose one of the highest mortality risks among all diseases in developed countries, steadily increasing the burden on the health systems. Early diagnosis of cardiovascular diseases has consequently become highly important to decrease mortality and to use more adapted therapeutic decisions. We demonstrate here the utility of nitrogen-doped reduced graphene oxide (N-prGO) for detecting and quantifying of cardiac troponin I (cTnI), a key human cardiac protein biomarker, under physiologically relevant conditions. Non-covalent modification of N-prGO by 1-pyrenecarboxylic acid (py-COOH) and poly(ethylene glycol) modified pyrene (py-PEG) ligands allowed the covalent integration of Tro4 aptamer, known for its high selectivity towards cTnI. Using differential pulse voltammetry (DPV), a label-free electrochemical sensor for cTnI for concentrations down to 1 pgmL(-1) in human serum could be obtained. This sensitive detection arises from the integration of a porous nanomaterial with excellent electrochemical properties being easily amendable to site-specific surface modification. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:180 / 187
页数:8
相关论文
共 50 条
  • [11] Nitrogen-doped graphene oxide/carbon nanotubes nanocomposite (N-doped GO/CNTs) as a sensitive electrochemical sensor for detection of oxymetholone in blood serum
    Liu, Youmin
    Peng, Chunzheng
    Liu, Hong Cun
    Ji, Huan
    Wang, Zheng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2022, 17 (11):
  • [12] A novel fluorescent aptasensor for the highly sensitive and selective detection of cardiac troponin I based on a graphene oxide platform
    Liu, Dongkui
    Lu, Xing
    Yang, Yiwen
    Zhai, Yunyun
    Zhang, Jian
    Li, Lei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (18) : 4285 - 4291
  • [13] Co2Nx/nitrogen-doped reduced graphene oxide for enzymeless glucose detection
    Kong, Lingjun
    Ren, Zhiyu
    Du, Shichao
    Wu, Jun
    Fu, Honggang
    CHEMICAL COMMUNICATIONS, 2014, 50 (38) : 4921 - 4923
  • [14] Comparative study on the structural and electrochemical properties of nitrogen-doped and nitrogen and sulfur co-doped reduced graphene oxide electrode prepared by hydrothermal technique
    Nathabumroong, Sarawudh
    Chanlek, Narong
    Sareein, Thanapong
    Chongsereecharoen, Ekachai
    Pakawanit, Phakkhannan
    Poochai, Chatwarin
    Eknapakul, Tanachat
    Sriprachuabwong, Chakrit
    Nakajima, Hideki
    Thangdee, Piyaporn
    Lomas, Tanom
    Rujirawat, Saroj
    Songsiriritthigul, Prayoon
    Manyum, Prapan
    Tuantranont, Adisorn
    Yimnirun, Rattikorn
    RADIATION PHYSICS AND CHEMISTRY, 2023, 208
  • [15] A sensitive porphyrin/reduced graphene oxide electrode for simultaneous detection of guanine and adenine
    Chen, Yalin
    Mei, Tao
    Chen, Yi
    Wang, Jianying
    Li, Jinhua
    Fu, Yang
    Dai, Guangchao
    Wang, Sheng
    Xiong, Weilai
    Wang, Xianbao
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2016, 20 (07) : 2055 - 2062
  • [16] A glassy carbon electrode modified with nitrogen-doped reduced graphene oxide and melamine for ultra-sensitive voltammetric determination of bisphenol A
    Qin, Jingyu
    Shen, Jing
    Xu, Xiangyang
    Yuan, Yuan
    He, Guangyu
    Chen, Haiqun
    MICROCHIMICA ACTA, 2018, 185 (10)
  • [17] Supercapacitors based on nitrogen-doped reduced graphene oxide and borocarbonitrides
    Gopalakrishnan, K.
    Moses, Kota
    Govindaraj, A.
    Rao, C. N. R.
    SOLID STATE COMMUNICATIONS, 2013, 175 : 43 - 50
  • [18] Electrochemical sensors based on nitrogen-doped reduced graphene oxide for the simultaneous detection of ascorbic acid, dopamine and uric acid
    Zhang, Haiyan
    Liu, Sen
    JOURNAL OF ALLOYS AND COMPOUNDS, 2020, 842
  • [19] Fabrication of polypyrrole-grafted nitrogen-doped graphene and its application for electrochemical detection of paraquat
    Li, Ji
    Lei, Wu
    Xu, Yujuan
    Zhang, Yuehua
    Xia, Mingzhu
    Wang, Fengyun
    ELECTROCHIMICA ACTA, 2015, 174 : 464 - 471
  • [20] Synthesis of nitrogen-doped carbon nanocages for sensitive electrochemical detection of uric acid
    Han, Ruiyu
    Ma, Jing
    Yang, Chaoju
    Cui, Tong
    Liu, Wenjiao
    Wang, Shusong
    MATERIALS LETTERS, 2019, 255