Sensitive electrochemical detection of cardiac troponin I in serum and saliva by nitrogen-doped porous reduced graphene oxide electrode

被引:111
作者
Chekin, Fereshteh [1 ,2 ]
Vasilescu, Alina [3 ]
Jijie, Roxana [2 ]
Singh, Santosh K. [4 ]
Kurungot, Sreekumar [4 ,5 ]
Iancu, Madalina [6 ]
Badea, Gabriela [6 ]
Boukherroub, Rabah [2 ]
Szunerits, Sabine [2 ]
机构
[1] Islamic Azad Univ, Ayatollah Amoli Branch, Dept Chem, Amol, Iran
[2] Univ Valenciennes, Univ Lille, CNRS, Cent Lille,ISEN,IEMN,UMR 8520, F-59000 Lille, France
[3] Int Ctr Biodynam, 1B Intrarea Portocalelor,Sect 6, Bucharest 060101, Romania
[4] CSIR, Natl Chem Lab, Phys & Mat Chem Div, Dr Homi Bhabha Rd, Pune 411008, Maharashtra, India
[5] Acad Sci & Innovat Res, Anusandhan Bhawan,2 RafiMarg, New Delhi 110001, India
[6] Agrippa Ionescu Emergency Clin Hosp, 7 Ion Mincu, Bucharest 011356, Romania
关键词
Cardiac troponin I; Electrochemical biosensor; Aptamer; Pyrene; Nitrogen-doped porous reduced graphene oxide; LABEL-FREE DETECTION; CARBON NANOTUBES; IMMUNOSENSOR; REDUCTION; FUNCTIONALIZATION; NANOPARTICLES;
D O I
10.1016/j.snb.2018.01.215
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Cardiovascular diseases pose one of the highest mortality risks among all diseases in developed countries, steadily increasing the burden on the health systems. Early diagnosis of cardiovascular diseases has consequently become highly important to decrease mortality and to use more adapted therapeutic decisions. We demonstrate here the utility of nitrogen-doped reduced graphene oxide (N-prGO) for detecting and quantifying of cardiac troponin I (cTnI), a key human cardiac protein biomarker, under physiologically relevant conditions. Non-covalent modification of N-prGO by 1-pyrenecarboxylic acid (py-COOH) and poly(ethylene glycol) modified pyrene (py-PEG) ligands allowed the covalent integration of Tro4 aptamer, known for its high selectivity towards cTnI. Using differential pulse voltammetry (DPV), a label-free electrochemical sensor for cTnI for concentrations down to 1 pgmL(-1) in human serum could be obtained. This sensitive detection arises from the integration of a porous nanomaterial with excellent electrochemical properties being easily amendable to site-specific surface modification. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:180 / 187
页数:8
相关论文
共 36 条
[1]  
AI-hindi H.A.-A. M., 2016, AL KUFA U J BIOL, V8, P53
[2]   Electrochemical polymerization of pyrene derivatives on functionalized carbon nanotubes for pseudocapacitive electrodes [J].
Bachman, John C. ;
Kavian, Reza ;
Graham, Daniel J. ;
Kim, Dong Young ;
Noda, Suguru ;
Nocera, Daniel G. ;
Shao-Horn, Yang ;
Lee, Seung Woo .
NATURE COMMUNICATIONS, 2015, 6
[3]   Functionalization of Diamond Nanoparticles Using "Click" Chemistry [J].
Barras, Alexandre ;
Szunerits, Sabine ;
Marcon, Lionel ;
Monfilliette-Dupont, Nicole ;
Boukherroub, Rabah .
LANGMUIR, 2010, 26 (16) :13168-13172
[4]   Reduced Graphene Oxide Modified Electrodes for Sensitive Sensing of Gliadin in Food Samples [J].
Chekin, Fereshteh ;
Singh, Santosh K. ;
Vasilescu, Alina ;
Dhavale, Vishal M. ;
Kurungot, Sreekumar ;
Boukherroub, Rabah ;
Szunerits, Sabine .
ACS SENSORS, 2016, 1 (12) :1462-1470
[5]   Nanocrystalline Fe-Fe2O3 particle-deposited N-doped graphene as an activity-modulated Pt-free electrocatalyst for oxygen reduction reaction [J].
Dhavale, Vishal M. ;
Singh, Santosh K. ;
Nadeema, Ayasha ;
Gaikwad, Sachin S. ;
Kurungot, Sreekumar .
NANOSCALE, 2015, 7 (47) :20117-20125
[6]   Nitrogen-Doped Reduced Graphene Oxide Prepared by Simultaneous Thermal Reduction and Nitrogen Doping of Graphene Oxide in Air and Its Application as an Electrocatalyst [J].
Du, Donghe ;
Li, Pengcheng ;
Ouyang, Jianyong .
ACS APPLIED MATERIALS & INTERFACES, 2015, 7 (48) :26952-26958
[7]   Progression in sensing cardiac troponin biomarker charge transductions on semiconducting nanomaterials [J].
Fathil, M. F. M. ;
Arshad, M. K. Md ;
Ruslinda, A. R. ;
Nuzaihan, M. ;
Gopinath, Subash C. B. ;
Adzhri, R. ;
Hashim, U. .
ANALYTICA CHIMICA ACTA, 2016, 935 :30-43
[8]   A carbon nanotube-based electrochemical immunosensor for cardiac troponin T [J].
Gomes-Filho, S. L. R. ;
Dias, A. C. M. S. ;
Silva, M. M. S. ;
Silva, B. V. M. ;
Dutra, R. F. .
MICROCHEMICAL JOURNAL, 2013, 109 :10-15
[9]   Recent Development of Cardiac Troponin I Detection [J].
Han, Xu ;
Li, Shanghao ;
Peng, Zhili ;
Othman, Abdelhameed M. ;
Leblanc, Roger .
ACS SENSORS, 2016, 1 (02) :106-114
[10]   Highly sensitive amperometric detection of cardiac troponin I using sandwich aptamers and screen-printed carbon electrodes [J].
Jo, Hunho ;
Her, Jin ;
Lee, Heehyun ;
Shim, Yoon-Bo ;
Ban, Changill .
TALANTA, 2017, 165 :442-448