Common carotid artery: Variability of Doppler US velocity measurements

被引:27
作者
Meyer, JI [1 ]
Khalil, RM [1 ]
Obuchowski, NA [1 ]
Baus, LK [1 ]
机构
[1] CLEVELAND CLIN FDN, DEPT BIOSTAT & EPIDEMIOL, CLEVELAND, OH 44195 USA
关键词
carotid arteries; flow dynamics; stenosis or obstruction; US;
D O I
10.1148/radiology.204.2.9240517
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if Doppler ultrasound (US) measurements of systolic velocity in the common carotid artery vary markedly with distance from the bifurcation. MATERIALS AND METHODS: Bilateral, insonation angle-corrected velocity was measured with US in the common carotid artery. Measurements were obtained 1, 2, 3, 4, and 5 cm from the carotid artery bifurcation in 20 volunteers (aged 25-43 years) with no history of neurologic or cardiovascular disease. RESULTS: Velocity in the common carotid artery increased with distance (toward the aorta) from the bifurcation (mean increase, 9 cm/sec for each centimeter of distance from the bifurcation, up to the 4-cm distance; P < .001). Velocity increased more rapidly in subjects who were younger (P < .001) and in those with a lower pulse rate (P = .001). CONCLUSION: The distance from the bifurcation at which common carotid artery velocity is measured should be standardized. This may increase the accuracy of the systolic velocity ratio for assessment of internal carotid artery stenosis and decrease some of the reported variability between different centers that perform US of the carotid artery.
引用
收藏
页码:339 / 341
页数:3
相关论文
共 11 条
  • [1] Bluth E I, 1988, Radiographics, V8, P487
  • [2] Daigle RJ, 1990, J VASC TECHNOL, V14, P206
  • [3] COLOR-FLOW DUPLEX SCANNING OF CAROTID ARTERIES - NEW VELOCITY CRITERIA-BASED ON RECEIVER OPERATOR CHARACTERISTIC ANALYSIS FOR THRESHOLD STENOSES USED IN THE SYMPTOMATIC AND ASYMPTOMATIC CAROTID TRIALS
    FAUGHT, WE
    MATTOS, MA
    VANBEMMELEN, PS
    HODGSON, KJ
    BARKMEIER, LD
    RAMSEY, DE
    SUMNER, DS
    [J]. JOURNAL OF VASCULAR SURGERY, 1994, 19 (05) : 818 - 828
  • [4] ESTIMATION OF ARTERIAL STIFFNESS, COMPLIANCE, AND DISTENSIBILITY FROM M-MODE ULTRASOUND MEASUREMENTS OF THE COMMON CAROTID-ARTERY
    GAMBLE, G
    ZORN, J
    SANDERS, G
    MACMAHON, S
    SHARPE, N
    [J]. STROKE, 1994, 25 (01) : 11 - 16
  • [5] Howard G, 1991, J Stroke Cerebrovasc Dis, V1, P166, DOI 10.1016/S1052-3057(10)80013-8
  • [6] DETECTION AND QUANTIFICATION OF CAROTID-ARTERY STENOSIS - EFFICACY OF VARIOUS DOPPLER VELOCITY PARAMETERS
    HUNINK, MGM
    POLAK, JF
    BARLAN, MM
    OLEARY, DH
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (03) : 619 - 625
  • [7] SOURCES OF VARIABILITY IN CAROTID DUPLEX EXAMINATION - A PROSPECTIVE-STUDY
    KOHLER, T
    LANGLOIS, Y
    ROEDERER, GO
    PHILLIPS, DJ
    BEACH, KW
    PRIMOZICH, J
    LAWRENCE, R
    NICHOLLS, SC
    STRANDNESS, DE
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1985, 11 (04) : 571 - 576
  • [8] ROMAN MJ, 1992, J HYPERTENS, V10, pS115
  • [9] SMITH LL, 1993, J VASC TECHNOL, V17, P17
  • [10] CORRELATION OF ULTRASOUND-MEASURED COMMON CAROTID-ARTERY STIFFNESS WITH PATHOLOGICAL FINDINGS
    WADA, T
    KODAIRA, K
    FUJISHIRO, K
    MAIE, K
    TSUKIYAMA, E
    FUKUMOTO, T
    UCHIDA, T
    YAMAZAKI, S
    [J]. ARTERIOSCLEROSIS AND THROMBOSIS, 1994, 14 (03): : 479 - 482