Changes in molecular markers of hemostatic and fibrinolytic activation under various sampling conditions using vacuum tube samples from healthy volunteers

被引:16
作者
Omote, Mika [2 ]
Asakura, Hidesaku [1 ]
Takamichi, Sayuri [2 ]
Shibayama, Masami [2 ]
Yoshida, Tomotaka [2 ]
Kadohira, Yasuko [1 ]
Maekawa, Mio [1 ]
Yamazaki, Masahide [1 ]
Morishita, Eriko [1 ]
Nakao, Shinji [1 ]
Wada, Takashi [2 ]
机构
[1] Kanazawa Univ, Sch Med, Dept Internal Med 3, Kanazawa, Ishikawa 9208641, Japan
[2] Kanazawa Univ, Sch Med, Dept Clin Lab, Kanazawa, Ishikawa 9208641, Japan
关键词
Thrombin-antithrombin complex; Soluble fibrin; prothrombin fragment 1+2; D-dimer; Sampling condition;
D O I
10.1016/j.thromres.2008.05.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Molecular makers such as thrombin-antithrombin complex (TAT), prothrombin fragment 1 + 2 (F1 + 2), soluble fibrin (SF), and D-dimer, are useful markers in the diagnosis and assessment of various thrombotic conditions. These markers are measured in plasma after blood sampling. Difficult blood sampling is known to falsely elevate plasma TAT levels. However, it is not known exactly why this occurs. In the present study, we examined how levels of molecular markers of haemostatic and fibrinolytic activation change under various sampling conditions using vacuum tube samples from healthy volunteers. When blood was sampled continuously by taking 10 consecutive vacuum tube samples following application of a tourniquet, blood sampling resulted in an accurate assessment of these molecular makers. When blood was sampled continuously by taking vacuum tube samples every one minute over a total of 9 minutes to investigate possible changes in the levels of the molecular markers over time, plasma levels of TAT, SF, and F1 + 2 gradually increased with time. Plasma levels of TAT, F1 + 2, and SF increased beyond the normal range over the course of nine minutes. When blood was sampled using three alternative methods, which varied in terms of the duration of needle puncture (sampling B), duration of tourniquet use (sampling C), or both (sampling A), plasma TAT and SF levels were significantly increased with all three methods, compared to control samples. Plasma F1 + 2 levels were significantly increased with sampling methods A and B, compared to control samples, but not with sampling method C. On the other hand, plasma D-dimer levels were not significantly altered by any of the sampling methods. In conclusion, the results suggest that molecular markers of haemostatic and fibrinolytic activation, except for D-dimer, may be affected by sampling method, particularly the duration of needle puncturing. Therefore, care needs to be taken when using TAT, F1 + 2, and SF levels to diagnose and estimate activation of the coagulation system. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 16 条
[1]   Activation markers of coagulation and fibrinolysis in twins:: heritability of the prethrombotic state [J].
Ariëns, RAS ;
de Lange, M ;
Snieder, H ;
Boothby, M ;
Spector, TD ;
Grant, PJ .
LANCET, 2002, 359 (9307) :667-671
[2]   Venous thromboembolism from air travel - The LONFLIT study [J].
Belcaro, G ;
Geroulakos, G ;
Nicolaides, AN ;
Myers, KA ;
Winford, M .
ANGIOLOGY, 2001, 52 (06) :369-374
[3]   MEASUREMENT OF D-DIMER IN PLASMA AS DIAGNOSTIC-AID IN SUSPECTED PULMONARY-EMBOLISM [J].
BOUNAMEAUX, H ;
CIRAFICI, P ;
DEMOERLOOSE, P ;
SCHNEIDER, PA ;
SLOSMAN, D ;
REBER, G ;
UNGER, PF .
LANCET, 1991, 337 (8735) :196-200
[4]   Fibrin fragment D-dimer and the risk of future venous thrombosis [J].
Cushman, M ;
Folsom, AR ;
Wang, L ;
Aleksic, N ;
Rosamond, WD ;
Tracy, RP ;
Heckbert, SR .
BLOOD, 2003, 101 (04) :1243-1248
[5]  
DEVINE DV, 1986, BLOOD, V68, P317
[6]   Frequency of venous thromboembolism in low to moderate risk long distance air travellers: the New Zealand Air Traveller's Thrombosis (NZATT) study [J].
Hughes, RJ ;
Hopkins, RJ ;
Hill, S ;
Weatherall, M ;
Van de Water, N ;
Nowitz, M ;
Milne, D ;
Ayling, J ;
Wilsher, M ;
Beasley, R .
LANCET, 2003, 362 (9401) :2039-2044
[7]  
MOJCA B, 2003, THROMB RES, V108, P107
[8]  
PELZER H, 1991, THROMB HAEMOSTASIS, V65, P153
[9]  
PELZER H, 1988, THROMB HAEMOSTASIS, V59, P101
[10]   Non-invasive diagnosis of venous thromboembolism in outpatients [J].
Perrier, A ;
Desmarais, S ;
Miron, MJ ;
de Moerloose, P ;
Lepage, R ;
Slosman, D ;
Didier, D ;
Unger, PF ;
Patenaude, JV ;
Bounameaux, H .
LANCET, 1999, 353 (9148) :190-195