Endosaccular treatment of intracranial aneurysms using matrix coils - Early experience and midterm follow-up

被引:93
|
作者
Niimi, Y [1 ]
Song, J [1 ]
Madrid, M [1 ]
Berenstein, A [1 ]
机构
[1] St Lukes Roosevelt Hosp, Hyman Newman Inst Neurol & Neurosurg, Ctr Endovasc Surg, New York, NY 10019 USA
关键词
cerebral aneurysm; embolization; therapeutic;
D O I
10.1161/01.STR.0000206459.73897.a3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose - The authors report their experience using Matrix coils in the treatment of cerebral aneurysms. Methods - The outcomes of 72 consecutive patients ( 76 aneurysms) who underwent coiling using Matrix coils at our institution were retrospectively analyzed. Results - Seventy-four aneurysms in 70 patients were coiled using Matrix coils ( ranging 3% to 100% by coil length; mean 68.8%). Two patients underwent regular platinum coil embolization after failed Matrix coil placement. Thirty-two (42%) ruptured aneurysms were acutely treated. In 46 aneurysms, Matrix composed > 50% of coil length. Complete aneurysm occlusion was obtained in 13 aneurysms (17.6%), neck remnant in 30 (40.5%), and dome filling in 31 (41.9%). Procedural morbidity and mortality rates were 1.4% and 1.4%, respectively. Angiographic follow-up was obtained in 63.5% ( 47 of 74 aneurysms; average 12.2 months; range 0 to 34). In these 47 angiographically followed aneurysms, the overall recanalization rate was 57.4%. In aneurysms with > 50% Matrix coils, 76.1% had angiographic follow-up ( 35 of 46), and in this group, the overall recanalization rate was 54.3% ( 19 of 35): 25% ( 1 of 4) for very small ( < 5 mm); 33% ( 4 of 12) for small-size ( < 10 mm)/small-neck ( < 4 mm); and 63% ( 5 of 8) for small-size/wide-neck ( >= 4 mm). A total of 82% ( 9 of 11) recanalization occurred in large aneurysms ( >= 10 to 25 mm). Ten aneurysms (21.3%; 10 of 47) underwent retreatment. Clinical follow-up was obtained in 61 (86%) patients ( average 15 months; range 1 to 37): 87% of patients were Glasgow Outcome Scale 4 or 5. Conclusion - The use of Matrix coils resulted in worse recanalization rates than that reported for Guglielmi detachable bare platinum coils.
引用
收藏
页码:1028 / 1032
页数:5
相关论文
共 50 条
  • [41] Ultra-high-resolution subtraction CT angiography in the follow-up of treated intracranial aneurysms
    Meijer, Frederick J. A.
    Schuijf, Joanne D.
    de Vries, Joost
    Boogaarts, Hieronymus D.
    van der Woude, Willem-Jan
    Prokop, Mathias
    INSIGHTS INTO IMAGING, 2019, 10 (01)
  • [42] Four-Year Follow-Up on the First-in-Human Experience With Nautilus Intrasaccular System Assisted Coiling for Unruptured Intracranial Aneurysms
    Sakai, Nobuyuki
    Kawabata, Shuhei
    Funatsu, Takayuki
    Okuda, Tomohiro
    Akiyama, Ryo
    Beppu, Mikiya
    Matsui, Yuichi
    Adachi, Hiromasa
    Horiuchi, Kazufumi
    Imamura, Hirotoshi
    Sakai, Chiaki
    Tani, Shoichi
    Adachi, Hidemitsu
    Sasaki, Natsuhi
    Tokunaga, So
    Fukumitsu, Ryu
    Shigematsu, Tomoyoshi
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2023, 3 (03):
  • [43] Single-center experience with six-month follow-up of FRED Jr® flow diverters for intracranial aneurysms in small arteries
    Rautio, Riitta
    Rahi, Melissa
    Katila, Ari
    Rinne, Jaakko
    ACTA RADIOLOGICA, 2019, 60 (07) : 917 - 924
  • [44] Stent-assisted coiling of unruptured intracranial aneurysms: Long-term follow-up in 164 patients with 183 aneurysms
    Mine, Benjamin
    Aljishi, Ali
    D'Harcour, Jean-Bernard
    Brisbois, Denis
    Collignon, Laurent
    Lubicz, Boris
    JOURNAL OF NEURORADIOLOGY, 2014, 41 (05) : 322 - 328
  • [45] Stent-assisted coiling of intracranial aneurysms using LEO stents: long-term follow-up in 153 patients
    Sedat, Jacques
    Chau, Yves
    Gaudart, Jean
    Sachet, Marina
    Beuil, Stephanie
    Lonjon, Michel
    NEURORADIOLOGY, 2018, 60 (02) : 211 - 219
  • [46] Clinical and Angiographic Follow-Up of Stent-Only Therapy for Acute Intracranial Vertebrobasilar Dissecting Aneurysms
    Park, S. I.
    Kim, B. M.
    Kim, D. I.
    Shin, Y. S.
    Suh, S. H.
    Chung, E. C.
    Kim, S. Y.
    Kim, S. H.
    Won, Y. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (07) : 1351 - 1356
  • [47] Long-term Follow-up Angiography of Intracranial Aneurysms Treated with Cook Detachable Coil System
    Pardo, M. I.
    Pumar, J. M.
    Abal, D.
    Garcia-Allut, A.
    Blanco, M.
    Vazquez, F.
    NEURORADIOLOGY JOURNAL, 2008, 21 (05) : 712 - 716
  • [48] Early experience with the Penumbra SMART coil in the endovascular treatment of intracranial aneurysms: Safety and efficacy
    Stapleton, Christopher J.
    Torok, Collin M.
    Patel, Aman B.
    INTERVENTIONAL NEURORADIOLOGY, 2016, 22 (06) : 654 - 658
  • [49] Endovascular treatment of ruptured intracranial aneurysms in patients aged 65 years and older - Follow-up of 52 patients after 1 year
    Sedat, J
    Dib, M
    Lonjon, M
    Litrico, S
    Von Langsdorf, D
    Fontaine, D
    Paquis, P
    STROKE, 2002, 33 (11) : 2620 - 2625
  • [50] Long-term angiographic follow-up is mandatory after endovascular treatment of aneurysms
    Raymond, J
    Georganos, SA
    Guilbert, F
    Lambert, A
    Lamoureux, J
    Weill, A
    Roy, D
    RIVISTA DI NEURORADIOLOGIA, 2003, 16 (06): : 1175 - 1176