Endosaccular treatment of intracranial aneurysms using matrix coils - Early experience and midterm follow-up

被引:93
|
作者
Niimi, Y [1 ]
Song, J [1 ]
Madrid, M [1 ]
Berenstein, A [1 ]
机构
[1] St Lukes Roosevelt Hosp, Hyman Newman Inst Neurol & Neurosurg, Ctr Endovasc Surg, New York, NY 10019 USA
关键词
cerebral aneurysm; embolization; therapeutic;
D O I
10.1161/01.STR.0000206459.73897.a3
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose - The authors report their experience using Matrix coils in the treatment of cerebral aneurysms. Methods - The outcomes of 72 consecutive patients ( 76 aneurysms) who underwent coiling using Matrix coils at our institution were retrospectively analyzed. Results - Seventy-four aneurysms in 70 patients were coiled using Matrix coils ( ranging 3% to 100% by coil length; mean 68.8%). Two patients underwent regular platinum coil embolization after failed Matrix coil placement. Thirty-two (42%) ruptured aneurysms were acutely treated. In 46 aneurysms, Matrix composed > 50% of coil length. Complete aneurysm occlusion was obtained in 13 aneurysms (17.6%), neck remnant in 30 (40.5%), and dome filling in 31 (41.9%). Procedural morbidity and mortality rates were 1.4% and 1.4%, respectively. Angiographic follow-up was obtained in 63.5% ( 47 of 74 aneurysms; average 12.2 months; range 0 to 34). In these 47 angiographically followed aneurysms, the overall recanalization rate was 57.4%. In aneurysms with > 50% Matrix coils, 76.1% had angiographic follow-up ( 35 of 46), and in this group, the overall recanalization rate was 54.3% ( 19 of 35): 25% ( 1 of 4) for very small ( < 5 mm); 33% ( 4 of 12) for small-size ( < 10 mm)/small-neck ( < 4 mm); and 63% ( 5 of 8) for small-size/wide-neck ( >= 4 mm). A total of 82% ( 9 of 11) recanalization occurred in large aneurysms ( >= 10 to 25 mm). Ten aneurysms (21.3%; 10 of 47) underwent retreatment. Clinical follow-up was obtained in 61 (86%) patients ( average 15 months; range 1 to 37): 87% of patients were Glasgow Outcome Scale 4 or 5. Conclusion - The use of Matrix coils resulted in worse recanalization rates than that reported for Guglielmi detachable bare platinum coils.
引用
收藏
页码:1028 / 1032
页数:5
相关论文
共 50 条
  • [21] Midterm and long-term follow-up of cerebral aneurysms treated with flow diverter devices: a single-center experience
    Piano, Mariangela
    Valvassori, Luca
    Quilici, Luca
    Pero, Guglielmo
    Boccardi, Edoardo
    JOURNAL OF NEUROSURGERY, 2013, 118 (02) : 408 - 416
  • [22] Treatment of Intracranial Aneurysms Using the New Silk Vista Flow Diverter: Safety Outcomes at Short-Term Follow-Up
    Pumar, Jose M.
    Mosqueira, Antonio
    Olier, Jorge
    Rodriguez-Fernandez, Claudio
    Vega, Pedro
    Gonzalez-Diaz, Eva
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [23] Long-Term Follow-Up Study of Endovascularly Treated Intracranial Aneurysms
    Pyysalo, L. M.
    Keski-Nisula, L. H.
    Niskakangas, T. T.
    Kahara, V. J.
    Ohman, J. E.
    INTERVENTIONAL NEURORADIOLOGY, 2010, 16 (03): : 231 - 239
  • [24] Midterm follow-up after embolization of intracranial aneurysms proximal to the circle of Willis with the Silk Vista flow diverter: the I-MAMA registry
    Da Ros, Valerio
    Sabuzi, Federico
    D'Argento, Francesco
    Pedicelli, Alessandro
    Gavrilovic, Vladimir
    Sponza, Massimo
    Di Giuliano, Francesca
    Biraschi, Francesco
    Iacobucci, Marta
    Grillea, Giovanni
    Bartolo, Andrea
    Patassini, Mirko
    Remida, Paolo
    Quilici, Luca
    Farago, Giuseppe
    Varrassi, Marco
    Cavasin, Nicola
    Arpesani, Roberto
    Giordano, Aldo Victor
    Umana, Giuseppe
    Garaci, Francesco
    Floris, Roberto
    NEURORADIOLOGY, 2024, 66 (06) : 1013 - 1020
  • [25] Long-term Follow-up Study of Endovascularly Treated Intracranial Aneurysms
    Pyysalo, L. M.
    Keski-Nisula, L. H.
    Niskakangas, T. T.
    Kahara, V. J.
    Ohman, J. E.
    INTERVENTIONAL NEURORADIOLOGY, 2010, 16 (04): : 361 - 368
  • [26] Neuroform stent-assisted coiling of intracranial aneurysms: a 5 year single-center experience and follow-up
    Liang, Guobiao
    Gao, Xu
    Li, Zhiqing
    Wei, Xuezhong
    Xue, Hongli
    NEUROLOGICAL RESEARCH, 2010, 32 (07) : 721 - 727
  • [27] CONTRIBUTION OF MR-ANGIOGRAPHY TO THE DIAGNOSIS AND THE THERAPEUTIC INDICATION AND FOLLOW-UP OF INTRACRANIAL ANEURYSMS
    AUFFRAY, E
    DEKERSAINTGILLY, A
    HAVET, T
    SONIER, CB
    BUHE, T
    MANTOURA, J
    SZAPIRO, J
    JOURNAL OF NEURORADIOLOGY, 1994, 21 (01) : 17 - 29
  • [28] Endovascular treatment of acute intracranial vertebral artery dissection: long-term follow-up results of internal trapping and reconstructive treatment using coils and stents
    Nam, Kyoung Hyup
    Ko, Jun Kyeung
    Cha, Seung Heon
    Choi, Chang Hwa
    Lee, Tae Hong
    Lee, Jae Il
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2015, 7 (11) : 829 - 834
  • [29] Clinical and angiographic long-term follow-up of completely coiled intracranial aneurysms using endovascular technique
    Choi, Dae Seob
    Kim, Mun Chul
    Lee, Seon Kyu
    Willinsky, Robert A.
    Terbrugge, Karel G.
    JOURNAL OF NEUROSURGERY, 2010, 112 (03) : 575 - 581
  • [30] Long-term follow-up of the DERIVO® Embolization Device (DED®) for intracranial aneurysms: the Italian Multicentric Registry
    Piano, Mariangela
    Lozupone, Emilio
    Sgoifo, Annalisa
    Nuzzi, Nunzio P.
    Asteggiano, Francesco
    Pero, Guglielmo
    Quilici, Luca
    Iannucci, Giuseppe
    Cerini, Paolo
    Comelli, Chiara
    Peschillo, Simone
    Princiotta, Ciro
    Pedicelli, Alessandro
    Limbucci, Nicola
    Ganci, Giuseppe
    Trasimeni, Guido
    Ciceri, Elisa
    Farago, Giuseppe
    Giorgianni, Andrea
    De Nicola, Maurizio
    Remida, Paolo
    Lafe, Elvis
    Mardighian, Dikran
    Ruggiero, Maria
    Lazzarotti, Guido A.
    Cavasin, Nicola
    Castellan, Lucio
    Chiumarulo, Luigi
    Burdi, Nicola
    Paolucci, Aldo
    Briganti, Francesco
    Natrella, Massimiliano
    Florio, Francesco P.
    Pavia, Marco
    Gallesio, Ivan
    Lucente, Giuseppe
    Gozzoli, Luigi
    Caputo, Nevia
    Vagnarelli, Simone
    Boccardi, Edoardo
    Valvassori, Luca
    JOURNAL OF NEUROSURGICAL SCIENCES, 2021, 65 (03) : 361 - 368