Harmonic Suppression and Stability Analysis of Three-phase VSR with Cosine Internal Model Control Strategy

被引:0
|
作者
Liu, Bo [1 ]
Ben, Hongqi [1 ]
Meng, Tao [2 ]
Bai, Yinlong [1 ]
机构
[1] Harbin Inst Technol, Sch Elect Engn & Automat, Harbin, Peoples R China
[2] Heilongjiang Univ, Sch Mech & Elect Engn, Harbin, Peoples R China
来源
2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA) | 2016年
关键词
voltage source rectifier (VSR); harmonic suppression; cosine internal model (CIM); stability boundary; FILTERS; POWER;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, low-frequency harmonics of grid current in the three-phase voltage source rectifier (VSR) are analyzed. It indicates that dead-time effect, harmonics in drive signals and harmonics in grid voltage are the main reasons why harmonics exist in the grid current. Furthermore, a self-adjusting control strategy in current loop is proposed to suppress specific harmonics based on cosine internal model (CIM) control strategy. The system stability is effected by the added controller, and its stability boundary is calculated by Jacobian matrix, which gives constraints to design the controller parameters. Tested waveforms prove that harmonics can be suppressed by the proposed control strategy, and the numerical analysis is correct.
引用
收藏
页数:5
相关论文
共 42 条
  • [41] Steady-State Analysis of a ZVS Bidirectional Isolated Three-Phase DC-DC Converter Using Dual Phase-Shift Control With Variable Duty Cycle
    de Oliveira Filho, Herminio Miguel
    Oliveira, Demercil de Souza, Jr.
    Praca, Paulo Peixoto
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) : 1863 - 1872
  • [42] Model Predictive Current Control with Modified Synchronous Detection Technique for Three-Phase 3L-NPC Multi-Functional Solar Photovoltaic System
    Bonala, Anil Kumar
    Sandepudi, Srinivasa Rao
    Muddineni, Vishnu Prasad