Optical Coherence Tomography Findings in Lesions After Sirolimus-Eluting Stent Implantation With Peri-Stent Contrast Staining

被引:28
|
作者
Tada, Takeshi [1 ]
Kadota, Kazushige [1 ]
Hosogi, Shingo [2 ]
Kubo, Shunsuke [1 ]
Ozaki, Masatomo [1 ]
Yoshino, Mitsuru [1 ]
Miyake, Koshi [1 ]
Eguchi, Haruki [1 ]
Ohashi, Noriyuki [1 ]
Hayakawa, Yuki [1 ]
Saito, Naoki [1 ]
Otsuru, Suguru [1 ]
Hasegawa, Daiji [1 ]
Shigemoto, Yoshikazu [1 ]
Habara, Seiji [1 ]
Imai, Masao [3 ]
Tanaka, Hiroyuki [1 ]
Fuku, Yasushi [1 ]
Oka, Naoki [1 ]
Kato, Harumi [1 ]
Yamamoto, Hiroyuki [1 ]
Fujii, Satoki [1 ]
Goto, Tsuyoshi [1 ]
Mitsudo, Kazuaki [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiovasc Med, Kurashiki, Okayama 7108602, Japan
[2] Kochi Hlth Sci Ctr, Dept Cardiovasc Med, Kochi, Japan
[3] Kyoto Univ, Dept Cardiovasc Med, Grad Sch Med, Kyoto, Japan
关键词
peri-stent contrast staining; optical coherence tomography; incomplete stent apposition; multiple interstrut hollows; INTRAVASCULAR ULTRASOUND FINDINGS; BARE-METAL; APPOSITION; THROMBOSIS; HYPERSENSITIVITY; RESTENOSIS; PATTERNS; INSIGHTS;
D O I
10.1161/CIRCINTERVENTIONS.112.968487
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-We have sometimes noted abnormal angiographic coronary dilatation, <50% of the reference vessel, at the site of sirolimus-eluting stent implantation, suggesting contrast staining outside the stent struts and named this finding peri-stent contrast staining (PSS). Little was known about optical coherence tomography findings of lesions with PSS. Methods and Results-Between May 2008 and March 2010, we performed optical coherence tomography for 90 in-stent restenosis lesions after sirolimus-eluting stent implantation. We found PSS in 20 of the 90 lesions by coronary angiography. The differences in optical coherence tomography findings, including incomplete stent apposition, multiple interstrut hollows (MIH), strut coverage, and thrombus, were compared between lesions with PSS and those without PSS. PSS is defined as contrast staining outside the stent contour extending to >20% of the stent diameter measured by quantitative coronary angiography. MIH is defined as multiple hollows (the maximum depth >0.5 mm) existing between and outside well-apposed stent struts. Both incomplete stent apposition (60.0% versus 10%; P<0.001) and MIH (85.0% versus 25.7%; P<0.001) were frequently observed in lesions with PSS than in lesions without PSS. Among the 20 lesions with PSS, there was only 1 lesion in which we found neither MIH nor incomplete stent apposition, but only minor dissection. Uncovered struts (11.6% versus 3.9%; P=0.001), malapposed struts (2.0% versus 0.0%; P<0.001), and red thrombus (35% versus 10%; P=0.012) were frequently observed in lesions with PSS than in lesions without PSS. Conclusions-PSS might be closely associated with 2 different optical coherence tomography findings, MIH and incomplete stent apposition, in lesions after sirolimus-eluting stent implantation. (Circ Cardiovasc Interv. 2012;5:649-656.)
引用
收藏
页码:649 / 656
页数:8
相关论文
共 50 条
  • [21] Very late acquired peri-stent contrast staining and incomplete stent apposition with biodegradable polymer stents: Insight from optical coherence tomography
    Takashima, Hiroaki
    Sakurai, Shinichiro
    Waseda, Katsuhisa
    Kurita, Akiyoshi
    Ando, Hirohiko
    Kumagai, Soichiro
    Amano, Tetsuya
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 176 (01) : E11 - E12
  • [22] Histological validation of frequency domain optical coherence tomography for the evaluation of neointimal formation after a novel polymer-free sirolimus-eluting stent implantation
    Fu, Qiang
    Hu, Hongyu
    Chen, Wei
    Tan, Zhixu
    Li, Li
    Wang, Dezhao
    Chen, Buxing
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2015, 8 (09): : 11068 - 11075
  • [23] Stent Thrombosis Four and a Half Years After Implantation of A Sirolimus-Eluting Stent
    Korovesis, Socrates
    Katritsis, Demosthenes G.
    HELLENIC JOURNAL OF CARDIOLOGY, 2009, 50 (05) : 423 - 425
  • [24] Risk Factors and Clinical Impacts of Peri-Stent Contrast Staining After Second-Generation Drug-Eluting Stent Implantation
    Tokuda, Takahiro
    Yamawaki, Masahiro
    Mori, Shinsuke
    Takimura, Hideyuki
    Sakamoto, Yasunari
    Kobayashi, Norihiro
    Araki, Motoharu
    Hirano, Keisuke
    Ito, Yoshiaki
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2016, 29 (02) : 179 - 187
  • [25] Very Late Stent Thrombosis 5 Years After Implantation of a Sirolimus-Eluting Stent Observed by Angioscopy and Optical Coherence Tomography
    Ishihara, Takayuki
    Awata, Masaki
    Fujita, Masashi
    Watanabe, Tetsuya
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Uematsu, Masaaki
    JACC-CARDIOVASCULAR INTERVENTIONS, 2013, 6 (05) : E28 - E30
  • [26] Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography
    Hyun Hee Choi
    Jung-Sun Kim
    Duck Hyoung Yoon
    Kyung-Soon Hong
    Tae Hoon Kim
    Byeong Keuk Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2012, 28 : 491 - 497
  • [27] Late stent thrombosis after implantation of a sirolimus-eluting stent
    Kerner, A
    Gruberg, L
    Kapeliovich, M
    Grenadier, E
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2003, 60 (04) : 505 - 508
  • [28] Stent thrombosis after successful sirolimus-eluting stent implantation
    Jeremias, A
    Sylvia, B
    Bridges, J
    Kirtane, AJ
    Bigelow, B
    Pinto, DS
    Ho, KKL
    Cohen, DJ
    Garcia, LA
    Cutlip, DE
    Carrozza, JP
    CIRCULATION, 2004, 109 (16) : 1930 - 1932
  • [29] Persistent malapposition after implantation of sirolimus-eluting stent into intramural coronary hematoma - Optical coherence tomography observations
    Sawada, Takahiro
    Shite, Junya
    Shinke, Toshiro
    Watanabe, Satoshi
    Otake, Hiromasa
    Matsumoto, Daisuke
    Imuro, Yusuke
    Ogasawara, Daisuke
    Paredes, Oscal Luis
    Yokoyama, Mitsuhiro
    CIRCULATION JOURNAL, 2006, 70 (11) : 1515 - 1519
  • [30] Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography
    Li, Shan
    Gai, Luyue
    Yang, Tingshu
    Zhang, Li
    Xu, Xiuli
    Bai, Qicai
    Xu, Hang
    Wang, Yutang
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 768 - 775