Optical Coherence Tomography Findings in Lesions After Sirolimus-Eluting Stent Implantation With Peri-Stent Contrast Staining

被引:28
|
作者
Tada, Takeshi [1 ]
Kadota, Kazushige [1 ]
Hosogi, Shingo [2 ]
Kubo, Shunsuke [1 ]
Ozaki, Masatomo [1 ]
Yoshino, Mitsuru [1 ]
Miyake, Koshi [1 ]
Eguchi, Haruki [1 ]
Ohashi, Noriyuki [1 ]
Hayakawa, Yuki [1 ]
Saito, Naoki [1 ]
Otsuru, Suguru [1 ]
Hasegawa, Daiji [1 ]
Shigemoto, Yoshikazu [1 ]
Habara, Seiji [1 ]
Imai, Masao [3 ]
Tanaka, Hiroyuki [1 ]
Fuku, Yasushi [1 ]
Oka, Naoki [1 ]
Kato, Harumi [1 ]
Yamamoto, Hiroyuki [1 ]
Fujii, Satoki [1 ]
Goto, Tsuyoshi [1 ]
Mitsudo, Kazuaki [1 ]
机构
[1] Kurashiki Cent Hosp, Dept Cardiovasc Med, Kurashiki, Okayama 7108602, Japan
[2] Kochi Hlth Sci Ctr, Dept Cardiovasc Med, Kochi, Japan
[3] Kyoto Univ, Dept Cardiovasc Med, Grad Sch Med, Kyoto, Japan
关键词
peri-stent contrast staining; optical coherence tomography; incomplete stent apposition; multiple interstrut hollows; INTRAVASCULAR ULTRASOUND FINDINGS; BARE-METAL; APPOSITION; THROMBOSIS; HYPERSENSITIVITY; RESTENOSIS; PATTERNS; INSIGHTS;
D O I
10.1161/CIRCINTERVENTIONS.112.968487
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-We have sometimes noted abnormal angiographic coronary dilatation, <50% of the reference vessel, at the site of sirolimus-eluting stent implantation, suggesting contrast staining outside the stent struts and named this finding peri-stent contrast staining (PSS). Little was known about optical coherence tomography findings of lesions with PSS. Methods and Results-Between May 2008 and March 2010, we performed optical coherence tomography for 90 in-stent restenosis lesions after sirolimus-eluting stent implantation. We found PSS in 20 of the 90 lesions by coronary angiography. The differences in optical coherence tomography findings, including incomplete stent apposition, multiple interstrut hollows (MIH), strut coverage, and thrombus, were compared between lesions with PSS and those without PSS. PSS is defined as contrast staining outside the stent contour extending to >20% of the stent diameter measured by quantitative coronary angiography. MIH is defined as multiple hollows (the maximum depth >0.5 mm) existing between and outside well-apposed stent struts. Both incomplete stent apposition (60.0% versus 10%; P<0.001) and MIH (85.0% versus 25.7%; P<0.001) were frequently observed in lesions with PSS than in lesions without PSS. Among the 20 lesions with PSS, there was only 1 lesion in which we found neither MIH nor incomplete stent apposition, but only minor dissection. Uncovered struts (11.6% versus 3.9%; P=0.001), malapposed struts (2.0% versus 0.0%; P<0.001), and red thrombus (35% versus 10%; P=0.012) were frequently observed in lesions with PSS than in lesions without PSS. Conclusions-PSS might be closely associated with 2 different optical coherence tomography findings, MIH and incomplete stent apposition, in lesions after sirolimus-eluting stent implantation. (Circ Cardiovasc Interv. 2012;5:649-656.)
引用
收藏
页码:649 / 656
页数:8
相关论文
共 50 条
  • [1] Incidence, Risk Factors, and Clinical Sequelae of Angiographic Peri-Stent Contrast Staining After Sirolimus-Eluting Stent Implantation
    Imai, Masao
    Kadota, Kazushige
    Goto, Tsuyoshi
    Fujii, Satoki
    Yamamoto, Hiroyuki
    Fuku, Yasushi
    Hosogi, Shingo
    Hirono, Akitoshi
    Tanaka, Hiroyuki
    Tada, Takeshi
    Morimoto, Takeshi
    Shiomi, Hiroki
    Kozuma, Ken
    Inoue, Katsumi
    Suzuki, Nobuaki
    Kimura, Takeshi
    Mitsudo, Kazuaki
    CIRCULATION, 2011, 123 (21) : 2382 - 2391
  • [2] A case of active peri-stent inflammation after sirolimus-eluting stent implantation
    Kurosawa, Takafumi
    Kotani, Jun-ichi
    Matsuyama, Taka-aki
    Ishibashi-Ueda, Hatsue
    HEART AND VESSELS, 2015, 30 (02) : 270 - 273
  • [3] Various optical coherence tomographic findings in restenotic lesions after sirolimus-eluting stent implantation
    Takano, Masamichi
    Xie, Yong
    Murakami, Daisuke
    Inami, Shigenobu
    Yamamoto, Masanori
    Ohba, Takayoshi
    Seino, Yoshihiko
    Mizuno, Kyoichi
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 134 (02) : 263 - 265
  • [4] Unusual peri-stent strut contrast staining 6 years after sirolimus-eluting stent implantation: an “ant colony-like” appearance
    Yoji Neishi
    Hiroyuki Okura
    Kiyoshi Yoshida
    Heart and Vessels, 2014, 29 : 699 - 702
  • [5] Angioscopic Assessment of Peri-Stent Contrast Staining Following Drug-Eluting Stent Implantation
    Ishihara, Takayuki
    Awata, Masaki
    Fujita, Masashi
    Watanabe, Tetsuya
    Iida, Osamu
    Ishida, Yoshio
    Nanto, Shinsuke
    Uematsu, Masaaki
    CIRCULATION JOURNAL, 2014, 78 (01) : 122 - 127
  • [6] Unusual peri-stent strut contrast staining 6 years after sirolimus-eluting stent implantation: an "ant colony-like" appearance
    Neishi, Yoji
    Okura, Hiroyuki
    Yoshida, Kiyoshi
    HEART AND VESSELS, 2014, 29 (05) : 699 - 702
  • [7] Peri-stent contrast staining and very late stent thrombosis after sirolimus-eluting stent implantation: an observation from the RESTART (REgistry of Stent Thrombosis for review And Re-evaluaTion) angiographic substudy
    Kozuma, Ken
    Kimura, Takeshi
    Suzuki, Nobuaki
    Miyazawa, Akiyoshi
    Waseda, Katsuhisa
    Honda, Yasuhiro
    Morimoto, Takeshi
    Aizawa, Tadanori
    Mitsudo, Kazuaki
    Miyazaki, Shunichi
    Yamaguchi, Tetsu
    Isshiki, Takaaki
    EUROINTERVENTION, 2013, 9 (07) : 831 - 840
  • [8] Occurrence of Late Acquired Peri-Stent Contrast Staining Comparison Between Sirolimus-Eluting Stents and Everolimus-Eluting Stents
    Fujiwara, Takayuki
    Sakakura, Kenichi
    Ako, Junya
    Wada, Hiroshi
    Arao, Kenshiro
    Sugawara, Yoshitaka
    Momomura, Shin-ichi
    INTERNATIONAL HEART JOURNAL, 2012, 53 (03) : 165 - 169
  • [9] Impact of Dual Antiplatelet Therapy Beyond 1 Year on Clinical Outcomes of Patients With Stent Fracture or Peri-Stent Contrast Staining After Sirolimus-Eluting Stent Implantation
    Fuku, Yasushi
    Kadota, Kazushige
    Amano, Hidewo
    Kubo, Shunsuke
    Otsuru, Suguru
    Habara, Seiji
    Tada, Takeshi
    Tanaka, Hiroyuki
    Goto, Tsuyoshi
    CIRCULATION JOURNAL, 2018, 82 (01) : 211 - +
  • [10] Stent Fracture and Peri-Stent Contrast Staining After Everolimus-Eluting Stent Implantation-5-Year Outcomes
    Miura, Katsuya
    Tada, Takeshi
    Kuwayama, Akinune
    Shimada, Takenobu
    Ohya, Masanobu
    Amano, Hidewo
    Kubo, Shunsuke
    Hyodo, Yusuke
    Otsuru, Suguru
    Habara, Seiji
    Tanaka, Hiroyuki
    Fuku, Yasushi
    Goto, Tsuyoshi
    Kadota, Kazushige
    CIRCULATION JOURNAL, 2017, 81 (10) : 1514 - +