Failure analysis of spiral finned tube on the economizer

被引:19
|
作者
Liang, ZhiYuan [1 ]
Zhao, QinXin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermal Fluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Economizer; Piral finned tube; Wear mechanism; Dew point corrosion; CORROSION; ACID;
D O I
10.1016/j.engfailanal.2012.10.010
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This article describes the results of an investigation about the failure of spiral finned tube on a newly designed and retrofitted low pressure economizer in a 300 MW pulverized-coal-fired power plant. In order to find out the failure causes and to suggest preventive measures, phase compositions and macrostructure of the tithe metal surface were investigated by X-Ray Diffraction and Scanning Electron Microscope equipped with energy dispersive X-Ray spectroscopy micro-analysis. The results show that the failure was principally owing to comprehensive multiphase erosion, an interaction of the fly ash wearing, flue gas washing and sulfurous acid corrosion. Recommendations are given to minimize such failures. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:208 / 214
页数:7
相关论文
共 50 条
  • [1] Structure optimization and anti-abrasion property of spiral-finned-tube economizer
    Zhang, XS
    Cai, K
    ENERGY CONVERSION AND APPLICATION, VOL I AND II, 2001, : 884 - 886
  • [2] Corrosion Failure of an In-service Economizer Tube
    Roy, H.
    Sharma, P.
    Ghosh, D.
    Shukla, A. K.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2014, 14 (04) : 454 - 458
  • [3] Metallurgical Failure Analysis of Economizer Tube of Thermal Power Plant
    Husain, Md Murtuja
    Rajinikanth, V.
    Munda, Parikshit
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2024, 24 (01) : 352 - 367
  • [4] Failure analysis of a copper tube in a finned heat exchanger
    Peltola, H.
    Lindgren, M.
    ENGINEERING FAILURE ANALYSIS, 2015, 51 : 83 - 97
  • [5] CFD analysis of an economizer for heat transfer enhancement using serrated finned tube equipped with variable fin segments
    Babu, C. Rajesh
    Kumar, P.
    Roy, Sukanta
    Kanungo, Deepak
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 222 - 230
  • [6] Thermal design of a finned tubes economizer
    Perez Sanchez, Amaury
    Acosta Perez, Noemi
    Valero Almanza, Greisy, I
    Ranero Gonzalez, Elizabeth
    Perez Sanchez, Eddy J.
    NEXO REVISTA CIENTIFICA, 2021, 34 (06): : 1521 - 1549
  • [7] Failure analysis on abnormal corrosion of economizer tubes in a waste heat boiler
    Ding, Qun
    Tang, Xiao-Feng
    Yang, Zhen-Guo
    ENGINEERING FAILURE ANALYSIS, 2017, 73 : 129 - 138
  • [8] Failure analysis of boiler economizer tubes at power house
    Pal, Urbi
    Kishore, Kaushal
    Mukhopadhyay, Suman
    Mukhopadhyay, Goutam
    Bhattacharya, Sandip
    ENGINEERING FAILURE ANALYSIS, 2019, 104 : 1203 - 1210
  • [9] FAILURE ANALYSIS ON ABNORMAL THINNING OF ELBOWS IN THE ECONOMIZER AT WASTE HEAT BOILER SYSTEM
    Wang, Sheng-Hui
    Luo, Xiao-Ming
    Yang, Yu-Qing
    Tang, Jian
    Yang, Zhen-Guo
    ASME PRESSURE VESSELS AND PIPING CONFERENCE - 2015, VOL 6B, 2015,
  • [10] Deterioration of economizer tube in utility boiler
    Subramanian, Chidambaram
    ENGINEERING FAILURE ANALYSIS, 2020, 115