Performance Differences Between Conventional Smears and Liquid-Based Preparations of Thyroid Fine-Needle Aspiration Samples Analysis of 47 076 Responses in the College of American Pathologists Interlaboratory Comparison Program in Non-Gynecologic Cytology

被引:27
作者
Fischer, Andrew H. [1 ]
Clayton, Amy C. [2 ]
Bentz, Joel S. [3 ]
Wasserman, Patricia G. [4 ]
Henry, Michael R. [2 ]
Souers, Rhona J. [5 ]
Moriarty, Ann T. [6 ]
机构
[1] Univ Massachusetts, Dept Cytopathol, Worcester, MA 01605 USA
[2] Mayo Clin, Dept Anat Pathol, Rochester, MN USA
[3] Lab Med Consultants Ltd, Dept Pathol, Las Vegas, NV USA
[4] N Shore Long Isl Jewish Hlth Syst, Dept Anat Pathol Serv, New Hyde Pk, NY USA
[5] Coll Amer Pathologists, Dept Stat & Biostat, Northfield, IL USA
[6] AmeriPath Indiana, Dept Pathol, Indianapolis, IN USA
关键词
THINPREP(R) TECHNIQUE; FOLLICULAR NEOPLASMS; COLLOID NODULES; DISTINCTION; ARTIFACTS; UTILITY;
D O I
10.5858/arpa.2012-0009-CP
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-Controversy exists about whether thyroid fine-needle aspirates (FNAs) should be processed with conventional smears or liquid-based preparations (LBPs). Objective.-To compare the performance of conventional smears to LBPs for thyroid FNA slides circulated in the College of American Pathologists Interlaboratory Comparison Program in Non-Gynecologic Cytology. Design.-Participant responses for thyroid FNA slides were compared with the reference diagnosis at the level of 3 general diagnostic categories: negative, suspicious (which included only follicular and Hurthle cell neoplasm), and malignant. For specific reference diagnoses of benign/goiter and papillary thyroid carcinoma, the participants' specific diagnoses were analyzed and poorly performing slides were rereviewed. Results.-The 47 076 thyroid FNA slide responses, between 2001 and 2009, included 44 478 responses (94%) for conventional smears and 2598 responses (6%) for LBPs. For the general reference category negative, participant responses were discrepant in 14.9% of conventional smears compared with 5.9% for LBPs (P < .001). The specific reference diagnosis of benign/goiter was misdiagnosed as a follicular neoplasm in 7.8% of conventional smears, compared with 1.3% of LBP. For the general reference category of malignant, participant responses were discrepant in 7.3% of conventional smears compared with 14.7% of LBPs (P < .001). The specific reference diagnosis of papillary thyroid carcinoma was misdiagnosed as benign/goiter in 7.2% of LBPs, compared with 4.8% of conventional smears (p < .001). Conclusions.-LBPs performed worse than conventional smears for cases with a reference diagnosis of papillary thyroid carcinoma. However, LBPs performed better than conventional smears for cases with a benign reference diagnosis. Specific features in thyroid FNAs that may improve the diagnostic accuracy of LBPs and conventional smears are described. (Arch Pathol Lab Med. 2013;137:26-31; doi: 10.5858/arpa.2012-0009-CP)
引用
收藏
页码:26 / 31
页数:6
相关论文
共 16 条
  • [1] Cytologic artifacts and pitfalls of thyroid fine-needle aspiration using ThinPrep® -: A comparative retrospective review
    Afify, AM
    Liu, J
    Al-Khafaji, BM
    [J]. CANCER CYTOPATHOLOGY, 2001, 93 (03): : 179 - 186
  • [2] Amrikachi M, 2001, ARCH PATHOL LAB MED, V125, P484
  • [3] Fischer AH, 2001, HISTOL HISTOPATHOL, V16, P1, DOI 10.14670/HH-16.1
  • [4] Fischer AH., 2010, J CELL BIOCHEM, V110, P975
  • [5] Hemosiderin laden macrophages and hemosiderin within follicular cells distinguish benign follicular lesions from follicular neoplasms
    Jaffar, Reema
    Mohanty, Sambit K.
    Khan, Ashraf
    Fischer, Andrew H.
    [J]. CYTOJOURNAL, 2009, 6
  • [6] KUNG ITM, 1990, ACTA CYTOL, V34, P345
  • [7] KUNG ITM, 1989, ACTA CYTOL, V33, P53
  • [8] Thyroid fine-needle aspiration: Smears versus liquid-based preparations
    Ljung, Britt-Marie
    [J]. CANCER CYTOPATHOLOGY, 2008, 114 (03): : 144 - 148
  • [9] Improved Preoperative Definitive Diagnosis of Papillary Thyroid Carcinoma in FNAs Prepared With Both ThinPrep and Conventional Smears Compared With FNAs Prepared With ThinPrep Alone
    Luu, Martin H.
    Fischer, Andrew H.
    Pisharodi, Latha
    Owens, Christopher L.
    [J]. CANCER CYTOPATHOLOGY, 2011, 119 (01) : 68 - 73
  • [10] Use of a thin-layer technique in thyroid fine needle aspiration
    Malle, D
    Valeri, RM
    Pazaitou-Panajiotou, K
    Kiziridou, A
    Vainas, I
    Destouni, C
    [J]. ACTA CYTOLOGICA, 2006, 50 (01) : 23 - 27