Performance Differences Between Conventional Smears and Liquid-Based Preparations of Thyroid Fine-Needle Aspiration Samples Analysis of 47 076 Responses in the College of American Pathologists Interlaboratory Comparison Program in Non-Gynecologic Cytology

被引:28
作者
Fischer, Andrew H. [1 ]
Clayton, Amy C. [2 ]
Bentz, Joel S. [3 ]
Wasserman, Patricia G. [4 ]
Henry, Michael R. [2 ]
Souers, Rhona J. [5 ]
Moriarty, Ann T. [6 ]
机构
[1] Univ Massachusetts, Dept Cytopathol, Worcester, MA 01605 USA
[2] Mayo Clin, Dept Anat Pathol, Rochester, MN USA
[3] Lab Med Consultants Ltd, Dept Pathol, Las Vegas, NV USA
[4] N Shore Long Isl Jewish Hlth Syst, Dept Anat Pathol Serv, New Hyde Pk, NY USA
[5] Coll Amer Pathologists, Dept Stat & Biostat, Northfield, IL USA
[6] AmeriPath Indiana, Dept Pathol, Indianapolis, IN USA
关键词
THINPREP(R) TECHNIQUE; FOLLICULAR NEOPLASMS; COLLOID NODULES; DISTINCTION; ARTIFACTS; UTILITY;
D O I
10.5858/arpa.2012-0009-CP
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-Controversy exists about whether thyroid fine-needle aspirates (FNAs) should be processed with conventional smears or liquid-based preparations (LBPs). Objective.-To compare the performance of conventional smears to LBPs for thyroid FNA slides circulated in the College of American Pathologists Interlaboratory Comparison Program in Non-Gynecologic Cytology. Design.-Participant responses for thyroid FNA slides were compared with the reference diagnosis at the level of 3 general diagnostic categories: negative, suspicious (which included only follicular and Hurthle cell neoplasm), and malignant. For specific reference diagnoses of benign/goiter and papillary thyroid carcinoma, the participants' specific diagnoses were analyzed and poorly performing slides were rereviewed. Results.-The 47 076 thyroid FNA slide responses, between 2001 and 2009, included 44 478 responses (94%) for conventional smears and 2598 responses (6%) for LBPs. For the general reference category negative, participant responses were discrepant in 14.9% of conventional smears compared with 5.9% for LBPs (P < .001). The specific reference diagnosis of benign/goiter was misdiagnosed as a follicular neoplasm in 7.8% of conventional smears, compared with 1.3% of LBP. For the general reference category of malignant, participant responses were discrepant in 7.3% of conventional smears compared with 14.7% of LBPs (P < .001). The specific reference diagnosis of papillary thyroid carcinoma was misdiagnosed as benign/goiter in 7.2% of LBPs, compared with 4.8% of conventional smears (p < .001). Conclusions.-LBPs performed worse than conventional smears for cases with a reference diagnosis of papillary thyroid carcinoma. However, LBPs performed better than conventional smears for cases with a benign reference diagnosis. Specific features in thyroid FNAs that may improve the diagnostic accuracy of LBPs and conventional smears are described. (Arch Pathol Lab Med. 2013;137:26-31; doi: 10.5858/arpa.2012-0009-CP)
引用
收藏
页码:26 / 31
页数:6
相关论文
共 16 条
[1]   Cytologic artifacts and pitfalls of thyroid fine-needle aspiration using ThinPrep® -: A comparative retrospective review [J].
Afify, AM ;
Liu, J ;
Al-Khafaji, BM .
CANCER CYTOPATHOLOGY, 2001, 93 (03) :179-186
[2]  
Amrikachi M, 2001, ARCH PATHOL LAB MED, V125, P484
[3]  
Fischer AH, 2001, HISTOL HISTOPATHOL, V16, P1, DOI 10.14670/HH-16.1
[4]  
Fischer AH., 2010, J CELL BIOCHEM, V110, P975
[5]   Hemosiderin laden macrophages and hemosiderin within follicular cells distinguish benign follicular lesions from follicular neoplasms [J].
Jaffar, Reema ;
Mohanty, Sambit K. ;
Khan, Ashraf ;
Fischer, Andrew H. .
CYTOJOURNAL, 2009, 6
[6]  
KUNG ITM, 1990, ACTA CYTOL, V34, P345
[7]  
KUNG ITM, 1989, ACTA CYTOL, V33, P53
[8]   Thyroid fine-needle aspiration: Smears versus liquid-based preparations [J].
Ljung, Britt-Marie .
CANCER CYTOPATHOLOGY, 2008, 114 (03) :144-148
[9]   Improved Preoperative Definitive Diagnosis of Papillary Thyroid Carcinoma in FNAs Prepared With Both ThinPrep and Conventional Smears Compared With FNAs Prepared With ThinPrep Alone [J].
Luu, Martin H. ;
Fischer, Andrew H. ;
Pisharodi, Latha ;
Owens, Christopher L. .
CANCER CYTOPATHOLOGY, 2011, 119 (01) :68-73
[10]   Use of a thin-layer technique in thyroid fine needle aspiration [J].
Malle, D ;
Valeri, RM ;
Pazaitou-Panajiotou, K ;
Kiziridou, A ;
Vainas, I ;
Destouni, C .
ACTA CYTOLOGICA, 2006, 50 (01) :23-27