Arterial anastomosis without sutures using ring pin stapler for clinical renal transplantation: Comparison with suture anastomosis

被引:11
作者
Ye, G [1 ]
Mo, HG [1 ]
Wang, ZH [1 ]
Yi, SH [1 ]
Wang, XW [1 ]
Zhang, YF [1 ]
机构
[1] Third Mil Med Univ, Xinqiao Hosp, Ctr Nephrol, Dept Urol, Chongqing 400037, Peoples R China
关键词
kidney; transplantation; renal artery; surgical anastomosis; surgical staples;
D O I
10.1016/S0022-5347(05)00143-6
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: The metal ring pin stapler was initially developed for microvascular surgery and there has been little experience of their use in larger vessels. We determined if the titanium ring pin coupling system could be safely and rapidly applied for arterial reconstruction in clinical renal transplantation. Materials and Methods: The donor renal artery was end-to-end anastomosed to the internal iliac artery with titanium ring pin staplers in 36 patients. Anastomotic, clamp and total operative time and vascular problems were compared with those in the control group of sutured anastomosis in 39 transplant recipients. Results: The completion of mechanical anastomosis required half the time of suture anastomosis. Mean clamp time was 17.8 minutes in the nonsuture group and 28.1 minutes in the control group. There was no significant difference in total operative time between the 2 groups. A small anastomotic line leak was noted in each group, which was temporary and self-limited. There were no postoperative anastomotic failures, postoperative bleeding episodes or need to revise the anastomosis (100% patency rate) in the 2 groups. Of the patients 61 were followed for 2 to 5 years. Transplant renal artery stenosis was observed in 1 patient in the nonsuture group but 3 in the control group. Conclusions: The anastomotic technique with the ring pin system is safe and simple, permitting an expeditious and everting anastomosis with a smooth intima-to-intima junction. Application of this technique may decrease warm ischemia time and the incidence of anastomotic artery stenosis, thus, improving outcomes.
引用
收藏
页码:636 / 640
页数:5
相关论文
共 20 条
  • [1] INTERNAL MAMMARY-CORONARY ARTERY ANASTOMOSES - A METHOD UTILIZING NAKAYAMAS INSTRUMENT FOR SMALL VESSEL ANASTOMOSES
    ABE, K
    MAIN, FB
    GERBODE, F
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1966, 51 (06) : 808 - &
  • [2] CLINICAL-EXPERIENCE WITH THE UNILINK/3M PRECISE MICROVASCULAR ANASTOMOTIC DEVICE
    BERGGREN, A
    OSTRUP, LT
    RAGNARSSON, R
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1993, 27 (01): : 35 - 39
  • [3] Transplant renal artery stenosis
    Bruno, S
    Remuzzi, G
    Ruggenenti, P
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2004, 15 (01): : 134 - 141
  • [4] Renal artery stenosis in kidney transplants
    Fervenza, FC
    Lafayette, RA
    Alfrey, EJ
    Petersen, J
    [J]. AMERICAN JOURNAL OF KIDNEY DISEASES, 1998, 31 (01) : 142 - 148
  • [5] Jones JW, 1998, CLIN TRANSPLANT, V12, P70
  • [6] BLOOD-FLOW AND SCANNING ELECTRON-MICROSCOPE STUDY ON VENOUS MICRO-VASCULAR ANASTOMOSES WITH NAKAYAMA APPARATUS AND MANUAL SUTURE
    LIDMAN, D
    OSTRUP, LT
    [J]. SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1981, 15 (02): : 97 - 101
  • [7] MAZOLEWSKI P, 1998, VASCULAR SURG, P672
  • [8] MESSINA LM, 2002, VASCULAR SURG, P493
  • [9] Renal transplantation without sutures using the vascular clipping system for renal artery and vein anastomosis - A new technique
    Mital, D
    Foster, PF
    Jensik, SC
    delRio, JV
    Sankary, HN
    McChesney, LP
    Williams, JW
    [J]. TRANSPLANTATION, 1996, 62 (08) : 1171 - 1173
  • [10] OSTRUP LT, 1976, SCAND J PLAST RECONS, V10, P9, DOI 10.3109/02844317609169742