Retinal Nerve Fiber Layer Thickness Reproducibility Using Seven Different OCT Instruments

被引:113
作者
Pierro, Luisa [1 ]
Gagliardi, Marco [1 ]
Iuliano, Lorenzo [1 ]
Ambrosi, Alessandro [2 ]
Bandello, Francesco [1 ]
机构
[1] Univ Vita Salute San Raffaele, Dept Ophthalmol, San Raffaele Sci Inst, I-20132 Milan, Italy
[2] Univ Vita Salute San Raffaele, Milan, Italy
关键词
OPTICAL COHERENCE TOMOGRAPHY; SPECTRAL-DOMAIN OCT; CIRRUS-HD-OCT; TIME-DOMAIN; NORMAL EYES; HEALTHY EYES; COMPARABILITY; OCT/SLO; RTVUE;
D O I
10.1167/iovs.11-8644
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. The clinical utility of new optical coherence tomography (OCT) instruments strongly depends on measurements reproducibility. The aim of this study was to assess retinal nerve fiber layer (RNFL) thickness reproducibility using six different spectral-domain OCTs (SD-OCTs) and one time-domain OCT. METHODS. RNFL thickness (average and four quadrant) from six SD-OCTs (Spectral OCT/SLO OPKO/OTI, 3D-OCT 2000 Topcon, RS-3000 NIDEK, Cirrus HD-OCT Zeiss, RTVue-100 Optovue, and Spectralis Heidelberg) and one time-domain OCT (Stratus OCT Zeiss) was measured twice in 38 right eyes of 38 randomly chosen healthy volunteers by two masked operators. Inter-and intraoperator reproducibility was evaluated by the intraclass correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman test analysis. Instrument-to-instrument reproducibility was determined by ANOVA for repeated measures. We also tested how the devices disagree in terms of systemic bias and random error using a structural equation model. RESULTS. Mean RNFL average thickness ranged from 90.08 mu m to 106.51 mu m. Cirrus and Heidelberg showed the thinnest RNFL values in all measurements, Topcon the highest. ICC, CV, and Bland-Altman plots showed variable inter- and intraoperator agreement depending on the instrument. Heidelberg demonstrated the best interoperator (ICC, 0.92; CV, 1.56%) and intraoperator (ICC, 0.94 and 0.95; CV, 1.28% and 1.26%, respectively, for operator A and operator B) agreement for average RNFL thickness. CONCLUSIONS. Heidelberg demonstrated the higher agreement in inter-and intraoperator reproducibility, Optovue the worst. In light of our error analysis results, we found that a scale bias among instruments could interfere with a thorough RNFL monitoring, suggesting that best monitoring is obtained with the same operator and the same device. (Invest Ophthalmol Vis Sci. 2012; 53: 5912-5920) DOI:10.1167/iovs.11-8644
引用
收藏
页码:5912 / 5920
页数:9
相关论文
共 50 条
  • [1] Reproducibility of peripapillary retinal nerve fiber layer thickness measurements using Spectral Domain OCT in Brazilian patients
    Toscano, Daniela Araujo
    de Avila, Marcos Pereira
    Catai Chalita, Maria Regina
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (05) : 320 - 323
  • [2] Comparison of retinal nerve fiber layer and macular thickness measurements with Stratus OCT and OPKO/OTI OCT devices in healthy subjects
    Ozkok, Ahmet
    Akkan, Julide Canan Umurhan
    Tamcelik, Nevbahar
    Erdogan, Mehmet
    Comlekoglu, Didar Ucar
    Yildirim, Rengin
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (01) : 98 - 103
  • [3] Macular and retinal nerve fiber layer thickness measurement reproducibility using optical coherence tomography (OCT-3)
    Gürses-Özden, R
    Teng, C
    Vessani, R
    Zafar, S
    Liebmann, JM
    Ritch, R
    JOURNAL OF GLAUCOMA, 2004, 13 (03) : 238 - 244
  • [4] Effects of Changing Operators and Instruments on Time-Domain and Spectral-Domain OCT Measurements of Retinal Nerve Fiber Layer Thickness
    Mwanza, Jean-Claude
    Gendy, Mohamed G.
    Feuer, William J.
    Shi, Wei
    Budenz, Donald L.
    OPHTHALMIC SURGERY LASERS & IMAGING, 2011, 42 (04) : 328 - 337
  • [5] Retinal Nerve Fiber Layer Thickness in Normals Measured by Spectral Domain OCT
    Bendschneider, Delia
    Tornow, Ralf P.
    Horn, Folkert K.
    Laemmer, Robert
    Roessler, Christopher W.
    Juenemann, Anselm G.
    Kruse, Friedrich E.
    Mardin, Christian Y.
    JOURNAL OF GLAUCOMA, 2010, 19 (07) : 475 - 482
  • [6] Correlation in Retinal Nerve Fiber Layer Thickness between Two OCT Units
    Chen, Hsin-Yi
    Chang, Yue-Cune
    Lane, Hsien-Yuan
    OPTOMETRY AND VISION SCIENCE, 2011, 88 (11) : 1326 - 1332
  • [7] Reproducibility and agreement in evaluating retinal nerve fibre layer thickness between Stratus and Spectralis OCT
    Arthur, S. N.
    Smith, S. D.
    Wright, M. M.
    Grajewski, A. L.
    Wang, Q.
    Terry, J. M.
    Lee, M. S.
    EYE, 2011, 25 (02) : 192 - 200
  • [8] Reproducibility of peripapillary retinal nerve fiber layer thickness measurements with Cirrus HD-OCT in glaucomatous eyes
    Soltani-Moghadam, Reza
    Alizadeh, Yousef
    Leili, Ehsan Kazemnezhad
    Haghighi, Mohamadreza Absari
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (01) : 113 - 117
  • [9] Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Wu, Huijuan
    de Boer, Johannes F.
    Chen, Teresa C.
    JOURNAL OF GLAUCOMA, 2011, 20 (08) : 470 - 476
  • [10] Reproducibility of Retinal Nerve Fiber Thickness Measurements Using the Test-retest Function of Spectral OCT/SLO in Normal and Glaucomatous Eyes
    Lee, Sun Ho
    Kim, Seok Hwan
    Kim, Tae-Woo
    Park, Ki Ho
    Kim, Dong Myung
    JOURNAL OF GLAUCOMA, 2010, 19 (09) : 637 - 642