Different control objectives for grid-connected converter under unbalanced grid voltage using forgotten iterative filter as phase lock loop

被引:23
作者
Jiang, Weidong [1 ]
Hu, Yang [1 ]
Zhang, Yi [1 ]
Zhao, Deyong [1 ]
Wang, Lei [1 ]
机构
[1] Hefei Univ Technol, Sch Elect Engn & Automat, Hefei, Peoples R China
基金
中国国家自然科学基金;
关键词
ACTIVE POWER FILTER; NEGATIVE SEQUENCE; COMPENSATION; GENERATION; RECTIFIER; HARMONICS; STRATEGY; SYSTEM;
D O I
10.1049/iet-pel.2014.0653
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
As the grid-connected converter is operating in the unbalanced three-phase grid in the traditional control strategies, the even harmonics of the voltage appear in DC-link and the odd harmonics of the current in AC-link, which will severely affect the performance of the grid-connected converter. Under this circumstance, the unbalanced three-phase grid will bring various negative effects and difficulty to the control of the converter, such as the fluctuation of active and reactive powers, non-sinusoidal and unsymmetrical three-phase currents. First, this study analyses the form of the fluctuation of power based on the instantaneous power theory and establishes a mathematical model of a grid-connected converter under unbalanced grid voltage. And then, a more complete description of the control problem of the converter is given, after three different control objectives, the fluctuation of active/reactive power and the non-sinusoidal and unsymmetrical grid currents, are considered at the same time. A novel method of separating the instantaneous positive and negative sequence components is proposed and well applied during achieving the different control objectives. Finally, the experimental results are compared, showing that the strategy is effective.
引用
收藏
页码:1798 / 1807
页数:10
相关论文
共 22 条
[1]   Real-time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self-tuning filter [J].
Biricik, Samet ;
Redif, Soydan ;
Ozerdem, Ozgur C. ;
Khadem, Shafiuzzaman K. ;
Basu, Malabika .
IET POWER ELECTRONICS, 2014, 7 (07) :1895-1905
[2]   Voltage Support Control Strategies for Static Synchronous Compensators Under Unbalanced Voltage Sags [J].
Castilla, Miguel ;
Miret, Jaume ;
Camacho, Antonio ;
Matas, Jose ;
Garcia de Vicuna, Luis .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (02) :808-820
[3]   Medium-voltage level dynamic voltage restorer compensation strategy by positive and negative sequence extractions in multiple reference frames [J].
Chen, Guodong ;
Zhu, Miao ;
Cai, Xu .
IET POWER ELECTRONICS, 2014, 7 (07) :1747-1758
[4]   Enhanced fault ride through performance of self-excited induction generator-based wind park during unbalanced grid operation [J].
El Moursi, Mohamed ;
Goweily, Khaled ;
Badran, Ebrahim A. .
IET POWER ELECTRONICS, 2013, 6 (08) :1683-1695
[5]   Three-Phase PLLs With Fast Postfault Retracking and Steady-State Rejection of Voltage Unbalance and Harmonics by Means of Lead Compensation [J].
Freijedo, Francisco D. ;
Yepes, Alejandro G. ;
Lopez, Oscar ;
Vidal, Ana ;
Doval-Gandoy, Jesus .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (01) :85-97
[6]   Constant power control-based strategy for Vienna-type rectifiers to expand operating area under severe unbalanced grid [J].
Hang, Lijun ;
Zhang, Ming .
IET POWER ELECTRONICS, 2014, 7 (01) :41-49
[7]   HIL Evaluation of Power Flow Control Strategies for Energy Storage Connected to Smart Grid Under Unbalanced Conditions [J].
Ivanovic, Zoran R. ;
Adzic, Evgenije M. ;
Vekic, Marko S. ;
Grabic, Stevan U. ;
Celanovic, Nikola L. ;
Katic, Vladimir A. .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2012, 27 (11) :4699-4710
[8]  
Jaber A., 2014, IET POWER ELECTRON, V7, p[1609, 2600]
[9]  
Kazmierkowski M P., 1994, Automatic Control of Converter-fed Drives
[10]   Harmonic power compensation capacity of shunt active power filter and its relationship with design parameters [J].
Khadem, Shafiuzzaman K. ;
Basu, Malabika ;
Conlon, Michael F. .
IET POWER ELECTRONICS, 2014, 7 (02) :418-430